RF

RF is a UTE (France, NF C 30-202 traditional system) cable designation: R = Cross-Linked Polyethylene (XLPE); F = Steel Tape Armour.

8 coding systems recognise this code

Standard, worked reading and related types

Worked reading of RF:

  • RF: R = Cross-Linked Polyethylene (XLPE); F = Steel Tape Armour

Related cable types: RFOU · RFOU(i) · H05RR-F · TTRF-70 · SURFIX · SUPERFLEX

UTE (France, NF C 30-202 traditional system)

SymbolMeaning
RCross-Linked Polyethylene (XLPE)
FSteel Tape Armour

How to read a UTE (France, NF C 30-202 traditional system) cable code

China (GB / JB/T / MT cable model codes)

SymbolMeaning
RFlexible Cable
FChloroprene Rubber

How to read a China (GB / JB/T / MT cable model codes) cable code

NEC Article 402 (US fixture wires, NFPA 70)

SymbolMeaning
RHeat-Resistant Rubber Or Cross-Linked Synthetic Polymer (Thermoset)
FFixture Wire, Solid Or 7-Strand

How to read a NEC Article 402 (US fixture wires, NFPA 70) cable code

CEI-UNEL 35011 (Italy)

SymbolMeaning
RMulti-Wire, Round-Section, Class 2
FRound Steel Wire

How to read a CEI-UNEL 35011 (Italy) cable code

Norwegian type designation (NEK 606 offshore and Norwegian land cables)

SymbolMeaning
REthylenepropylene Rubber (EPR)
FSemi-Conducting PE

How to read a Norwegian type designation (NEK 606 offshore and Norwegian land cables) cable code

India (IS 1554 / IS 7098 cable code)

SymbolMeaning
RElastomer (Rubber) Insulation Or Outer Sheath
FFlat Galvanized Steel Wire (Strip) Armour

How to read a India (IS 1554 / IS 7098 cable code) cable code

UNE (Spain: UNE 21123 / UNE 20434)

SymbolMeaning
RCross-Linked Polyethylene (XLPE)
FHelical Galvanized Steel Tape

How to read a UNE (Spain: UNE 21123 / UNE 20434) cable code

NEN 3207 / KEMA (Netherlands)

SymbolMeaning
RRound Conductor
FFine-Wired In Flexible Cables-Class 5

How to read a NEN 3207 / KEMA (Netherlands) cable code

How to read a UTE (France, NF C 30-202 traditional system) cable code

A UTE (France, NF C 30-202 traditional system) designation (France) is a row of letter groups, and each group stands for one part of the cable: conductor, insulation, screen, armour, sheath, or the standard it follows. The decoder knows 30 symbols for this system.

What does R mean in a UTE (France, NF C 30-202 traditional system) cable code? R means Cross-Linked Polyethylene (XLPE).

What does F mean in a UTE (France, NF C 30-202 traditional system) cable code? F means Steel Tape Armour.

Laying, sizes and datasheet: RF

Its sizes are in AWG and kcmil, which are not the same as the nearest mm²: compare them by area and by resistance. AWG to mm²

Terms on this page: steel tape armour

Work with RF

Who makes or stocks this cable?

Makers and stockists of this cable family appear here as sponsors for your region, each marked "Sponsored"; a listing never changes what this page says about the cable.

Related cables

More UTE (France, NF C 30-202 traditional system) designations

RF