RF
RF is a UTE (France, NF C 30-202 traditional system) cable designation: R = Cross-Linked Polyethylene (XLPE); F = Steel Tape Armour.
8 coding systems recognise this code
Standard, worked reading and related types
Worked reading of RF:
RF: R = Cross-Linked Polyethylene (XLPE); F = Steel Tape Armour
Related cable types: RFOU · RFOU(i) · H05RR-F · TTRF-70 · SURFIX · SUPERFLEX
UTE (France, NF C 30-202 traditional system)
| Symbol | Meaning |
|---|---|
R | Cross-Linked Polyethylene (XLPE) |
F | Steel Tape Armour |
How to read a UTE (France, NF C 30-202 traditional system) cable code
China (GB / JB/T / MT cable model codes)
| Symbol | Meaning |
|---|---|
R | Flexible Cable |
F | Chloroprene Rubber |
How to read a China (GB / JB/T / MT cable model codes) cable code
NEC Article 402 (US fixture wires, NFPA 70)
| Symbol | Meaning |
|---|---|
R | Heat-Resistant Rubber Or Cross-Linked Synthetic Polymer (Thermoset) |
F | Fixture Wire, Solid Or 7-Strand |
How to read a NEC Article 402 (US fixture wires, NFPA 70) cable code
CEI-UNEL 35011 (Italy)
| Symbol | Meaning |
|---|---|
R | Multi-Wire, Round-Section, Class 2 |
F | Round Steel Wire |
Norwegian type designation (NEK 606 offshore and Norwegian land cables)
| Symbol | Meaning |
|---|---|
R | Ethylenepropylene Rubber (EPR) |
F | Semi-Conducting PE |
How to read a Norwegian type designation (NEK 606 offshore and Norwegian land cables) cable code
India (IS 1554 / IS 7098 cable code)
| Symbol | Meaning |
|---|---|
R | Elastomer (Rubber) Insulation Or Outer Sheath |
F | Flat Galvanized Steel Wire (Strip) Armour |
How to read a India (IS 1554 / IS 7098 cable code) cable code
UNE (Spain: UNE 21123 / UNE 20434)
| Symbol | Meaning |
|---|---|
R | Cross-Linked Polyethylene (XLPE) |
F | Helical Galvanized Steel Tape |
NEN 3207 / KEMA (Netherlands)
| Symbol | Meaning |
|---|---|
R | Round Conductor |
F | Fine-Wired In Flexible Cables-Class 5 |
How to read a UTE (France, NF C 30-202 traditional system) cable code
A UTE (France, NF C 30-202 traditional system) designation (France) is a row of letter groups, and each group stands for one part of the cable: conductor, insulation, screen, armour, sheath, or the standard it follows. The decoder knows 30 symbols for this system.
What does R mean in a UTE (France, NF C 30-202 traditional system) cable code? R means Cross-Linked Polyethylene (XLPE).
What does F mean in a UTE (France, NF C 30-202 traditional system) cable code? F means Steel Tape Armour.
Laying, sizes and datasheet: RF
Its sizes are in AWG and kcmil, which are not the same as the nearest mm²: compare them by area and by resistance. AWG to mm²
Terms on this page: steel tape armour
Work with RF
Who makes or stocks this cable?
Makers and stockists of this cable family appear here as sponsors for your region, each marked "Sponsored"; a listing never changes what this page says about the cable.
Related cables
More UTE (France, NF C 30-202 traditional system) designations