NYRYRBY

NYRYRBY is a DIN VDE 0271/0276 power cables (Germany) cable designation: N = VDE Standard; Y = Polyvinyl Chloride (PVC); R = Round Steel Wire; Y = Polyvinyl Chloride (PVC); R = Round Steel Wire; B = Steel Tape Armour; Y = Polyvinyl Chloride (PVC).

2 coding systems recognise this code

Standard, worked reading and related types

Worked reading of NYRYRBY:

  • NYRYRBY: N = VDE Standard; Y = Polyvinyl Chloride (PVC); R = Round Steel Wire; Y = Polyvinyl Chloride (PVC); R = Round Steel Wire; B = Steel Tape Armour; Y = Polyvinyl Chloride (PVC)

Related cable types: NYCYBY · nykyby · nykyry

DIN VDE 0271/0276 power cables (Germany)

SymbolMeaning
NVDE Standard
YPolyvinyl Chloride (PVC)
RRound Steel Wire
YPolyvinyl Chloride (PVC)
RRound Steel Wire
BSteel Tape Armour
YPolyvinyl Chloride (PVC)

How to read a DIN VDE 0271/0276 power cables (Germany) cable code

China (GB / JB/T / MT cable model codes)

SymbolMeaning
NNylon Jacket
YPolyethylene (PE) Or Polyolefin
RFlexible Cable
YPolyethylene (PE) Or Polyolefin
RFlexible Cable
BPolypropylene (PP)
YPolyethylene (PE) Or Polyolefin

How to read a China (GB / JB/T / MT cable model codes) cable code

How to read a DIN VDE 0271/0276 power cables (Germany) cable code

A DIN VDE 0271/0276 power cables (Germany) designation (Germany) is a row of letter groups, and each group stands for one part of the cable: conductor, insulation, screen, armour, sheath, or the standard it follows. The decoder knows 51 symbols for this system.

What does N mean in a DIN VDE 0271/0276 power cables (Germany) cable code? N means VDE Standard.

What does Y mean in a DIN VDE 0271/0276 power cables (Germany) cable code? Y means Polyvinyl Chloride (PVC).

What does R mean in a DIN VDE 0271/0276 power cables (Germany) cable code? R means Round Steel Wire.

What does B mean in a DIN VDE 0271/0276 power cables (Germany) cable code? B means Steel Tape Armour.

Fire behaviour (EU CPR)

A CPR class is declared by the maker in its Declaration of Performance and printed on the sheath (EN 50575 cl 7). This decoder does not assign one. What the CPR classes mean →

Sources: EN 13501-6 draft and FprEN 50575:2014 final draft (drafts, not the published texts); IEC 60332-3-24:2000+A1:2008; EN 13501-3 draft A2.

Laying, sizes and datasheet: NYRYRBY

Terms on this page: steel tape armour

Work with NYRYRBY

Who makes or stocks this cable?

Makers and stockists of this cable family appear here as sponsors for your region, each marked "Sponsored"; a listing never changes what this page says about the cable.

Related cables

More DIN VDE 0271/0276 power cables (Germany) designations

NYRYRBY