NMD90

NMD90 is a CSA (Canada) cable designation: NM = Non-metallic sheathed cable; D = Dry (and damp) locations: CSA C22.1:24 Table 19 (p. 470) allows NMD90 in dry and damp locations, not wet; 90 = Maximum conductor temperature 90 C; NMD90 = Non-metallic sheathed cable for dry locations, 300 V, 90 C. 300 V, 90 C, FT1. CSA C22.2 No. 48.

1 coding system recognises this code

Standard, worked reading and related types

Standards behind these values: CSA C22.2 No. 48: Nonmetallic sheathed cable. How the values are sourced

Worked reading of NMD90 2/C 14 AWG, 300 V:

  • NMD90: NM = Non-metallic sheathed cable; D = Dry (and damp) locations: CSA C22.1:24 Table 19 (p. 470) allows NMD90 in dry and damp locations, not wet; 90 = Maximum conductor temperature 90 C; NMD90 = Non-metallic sheathed cable for dry locations, 300 V, 90 C. 300 V, 90 C, FT1. CSA C22.2 No. 48
  • 2/C 14 AWG, 300 V: 2 cores, each copper 14 AWG (2.1 mm²); rated voltage 300 V

Related cable types: NMD90 14/2 300 V

CSA (Canada)

SymbolMeaning
NMNon-metallic sheathed cable
DDry (and damp) locations: CSA C22.1:24 Table 19 (p. 470) allows NMD90 in dry and damp locations, not wet
90Maximum conductor temperature 90 C
NMD90Non-metallic sheathed cable for dry locations, 300 V, 90 C. 300 V, 90 C, FT1. CSA C22.2 No. 48

What is NMD90 cable?

NMD90: Non-metallic sheathed cable for dry locations, 300 V, 90 C. Rating: 300 V, 90 C, FT1. Standard: CSA C22.2 No. 48.

The Nassau page calls the insulation both "90C XLPE (R90)" and "white PVC Nylon T90"; drawn as PVC with nylon (sources disagree). Loomex and Canadex are trade names (Guillevin article, Nexans line card). CSA C22.1:24 (standard, read 2026-11-10): Table D1 allows both insulations the sources name: 90 C heat-resistant thermoplastic with a nylon sheath, or cross-linked polyethylene with no covering, under a thermoplastic outer covering; 300 V, 2, 3 or 4 conductors, 14 to 2 AWG. Table 19: 90 C, dry and damp locations, not wet; feeders, branch circuits and Class 2 circuits, not consumer's services; exposed or concealed, in raceways under Rule 12-568 2), not in cable trays, not for direct burial, not exposed to sunlight.

Documents and pages the readings were taken from

CSA (Canada): how to read the cable type names

Not equivalent, because

IEC 60332-1-2 ≠ VW-1 (UL 2556 FV-2) / FT1

Not equivalent, because The flame, the number of flame applications and the pass criterion differ: a cable that passes one has not shown that it passes the other.

IEC 60332-1-2

  • One 1 kW flame on a single vertical cable, applied once for a time set by the cable diameter. Sources: IEC 60332-1-2:2004+AMD1:2015 (edition 1.1), Table 1 p. 7 (flame time by diameter), Annex A p. 11 (recommended pass) (read in the standard)
  • Pass: the char ends at least 50 mm below the top clamp and no lower than 540 mm below it. Sources: IEC 60332-1-2:2004+AMD1:2015 (edition 1.1), Table 1 p. 7 (flame time by diameter), Annex A p. 11 (recommended pass) (read in the standard)
  • CPR class Eca uses the same test: the flame stops within 425 mm. Sources: EN 13501-6 draft (BSI FSH/21_11_0073, undated, before the published EN 13501-6:2014), Table 1 (read in a draft)

VW-1 (UL 2556 FV-2) / FT1

  • 5 flame applications of 15 s each. Sources: UL 1581, 4th ed. revised to 2013-01-30, clause 1080.1 (the VW-1 method, now UL 2556 FV-2) (read in the standard)
  • Judged by a paper indicator flag above the flame and cotton below the cable; their limits are not held here. Sources: UL 1581, 4th ed. revised to 2013-01-30, clause 1080.1 (the VW-1 method, now UL 2556 FV-2) (read in the standard)

All the comparisons →

NMD90 as the cable designer builds it, 2/C 14 AWG, 300 V

Flat, 9.9 × 4.9 mm (width × thickness), about 110 kg/km. Nominal values from the standard's tables for this size, computed, not a maker's data.

LayerMaterialThickness, mmOver the layer, mm
InsulationPVC0.763.1
Nylon jacket (polyamide)Nylon (PA)0.103.4
SheathPVC0.764.9

NMD90 on a drum

The smallest drum that passes every check, for 9.9 mm and about 110 kg/km as the cable designer builds it. Drums as their makers print them; lengths are estimates: whole layers wound nested (each turn in the groove of the layer below), wound diameter 1.05 × OD, 50 mm freeboard under the flange rim. Cable makers' own tables print less, as they count aligned layers.

LengthDrum size (its makers)LayersGross weight
500 mNEMA 24x18x10, wood NEMA reels (North America), American Wire Group, Okonite11 of 1466–69 kg
1,000 mNEMA 30x18x12, wood NEMA reels (North America), American Wire Group, Okonite17 of 19128–130 kg

Barrel at least 15 × OD = 148 mm for a cable of this kind (Low voltage, multi-core): KTG table, the cable's datasheet wins. A load rating is the drum maker's own. A steel drum whose maker prints none is checked against the DIN 46391-4 guide load instead: 28 kN per m³ of gross winding volume.

Other lengths, drums and weights: the cable drum calculator

Load it on a truck: 1000 m on its drum in the loading planner

Laying, sizes and datasheet: NMD90

NMD90 belongs to the family North American cables: the lowest laying temperature, bending radius, pulling, depth, drum handling and the test after laying, every rule with its sources. Laying and handling guide: North American cables

Its sizes are in AWG and kcmil, which are not the same as the nearest mm²: compare them by area and by resistance. AWG to mm²