KVVR

KVVR is a China (GB / JB/T / MT cable model codes) cable designation: K = Control Cable; V = Polyvinyl Chloride (PVC); V = Polyvinyl Chloride (PVC); R = Flexible Cable.

2 coding systems recognise this code

Standard, worked reading and related types

Standards behind these values: IEC 60502-1:2004 (edition 2.0): Power cables with extruded insulation and their accessories for rated voltages from 1 kV (Um = 1,2 kV) up to 30 kV (Um = 36 kV) - Part 1: Cables for rated voltages of 1 kV (Um = 1,2 kV) and 3 kV (Um = 3,6 kV); IEC 60228:2023 (edition 4.0): Conductors of insulated cables. How the values are sourced

Worked reading of KVVR 4x1.5 450/750 V:

  • KVVR: K = Control Cable; V = Polyvinyl Chloride (PVC); V = Polyvinyl Chloride (PVC); R = Flexible Cable
  • 4x1.5 450/750 V: 4 cores, each copper 1.5 mm²; rated voltage 0.45/0.75 kV

Related cable types: WDZC-KVVR · YVV-R · KVV · VVR

China (GB / JB/T / MT cable model codes)

SymbolMeaning
KControl Cable
VPolyvinyl Chloride (PVC)
VPolyvinyl Chloride (PVC)
RFlexible Cable

How to read a China (GB / JB/T / MT cable model codes) cable code

Norwegian type designation (NEK 606 offshore and Norwegian land cables)

SymbolMeaning
KPaper
VScreen (Draka key: aluminium screen; Nexans key: screen, optionally with PVC)
VDouble Wire Armour (Two Layers)
REthylene Propylene Rubber (EPR)

How to read a Norwegian type designation (NEK 606 offshore and Norwegian land cables) cable code

How to read a China (GB / JB/T / MT cable model codes) cable code

A China (GB / JB/T / MT cable model codes) designation (China) is a row of letter groups, and each group stands for one part of the cable: conductor, insulation, screen, armour, sheath, or the standard it follows. The decoder knows 137 symbols for this system.

What does K mean in a China (GB / JB/T / MT cable model codes) cable code? K means Control Cable.

What does V mean in a China (GB / JB/T / MT cable model codes) cable code? V means Polyvinyl Chloride (PVC).

What does R mean in a China (GB / JB/T / MT cable model codes) cable code? R means Flexible Cable.

Fire behaviour (EU CPR)

A CPR class is declared by the maker in its Declaration of Performance and printed on the sheath (EN 50575 cl 7). This decoder does not assign one. What the CPR classes mean →

Sources: EN 13501-6 draft and FprEN 50575:2014 final draft (drafts, not the published texts); IEC 60332-3-24:2000+A1:2008; EN 13501-3 draft A2.

KVVR: equivalents in other countries

Shown for 4x1.5 450/750 V. Each country's rules are applied to this build, keeping the conductor, section, cores, voltage, screen, armour and sheath.

CountryStandardName in that countryVerdictDifferences
IndiaIS 694FR FLEXIBLE 4x1,5 1100 VCloserated higher: 1100 V (this cable 450/750 V); Insulation 0.7 → 0.6 mm; Sheath 1.2 → 1 mm; Overall diameter 9.51 → 8.63 mm

No equivalent in: EN 50525-2-11 (rated lower: 300/500 V (this cable 450/750 V)); EN 50525-2-51 (rated lower: 300/500 V (this cable 450/750 V)); DIN VDE 0250-405 (rated lower: 300/500 V (this cable 450/750 V)).

Nominal values computed by each standard's rules, not manufacturer data. This is not a statement that two cables are interchangeable: the buyer's specification and the maker's type test decide.

KVVR as the cable designer builds it, 4x1.5 450/750 V

Overall diameter 9.5 mm, about 140 kg/km. Nominal values from the standard's tables for this size, computed, not a maker's data.

LayerMaterialThickness, mmOver the layer, mm
InsulationPVC0.702.9
FillerPP7.1
SheathPVC1.29.5

KVVR on a drum

The smallest drum that passes every check, for 9.5 mm and about 140 kg/km as the cable designer builds it. Drums as their makers print them; lengths are estimates: whole layers wound nested (each turn in the groove of the layer below), wound diameter 1.05 × OD, 50 mm freeboard under the flange rim. Cable makers' own tables print less, as they count aligned layers.

LengthDrum size (its makers)LayersGross weight
500 mKTG 6 (600 mm flange), plywood KTG drums (Europe), Bayka12 of 1477 kg
1,000 mKTG 8 (800 mm flange), wood KTG drums (Europe), Bayka, KTG16 of 17171–175 kg

Barrel at least 12 × OD = 114 mm for a cable of this kind (Flexible cable (class 5 or 6 conductor)): KTG table, the cable's datasheet wins. A load rating is the drum maker's own. A steel drum whose maker prints none is checked against the DIN 46391-4 guide load instead: 28 kN per m³ of gross winding volume.

Other lengths, drums and weights: the cable drum calculator

Load it on a truck: 1000 m on its drum in the loading planner

Laying, sizes and datasheet: KVVR

Selling this cable? Open it in the designer and get a datasheet with your logo (Pro). Open the cable designer · See Pro

Work with KVVR

Who makes or stocks this cable?

Makers and stockists of this cable family appear here as sponsors for your region, each marked "Sponsored"; a listing never changes what this page says about the cable.

Related cables

More China (GB / JB/T / MT cable model codes) designations

KVVR