HFFR
HFFR is a DIN VDE 0271/0276 power cables (Germany) cable designation: H = Halogen-Free Compound (Insulation Or Sheath, E.g. NHXH, N2XSEHRH); Older MV Cables: Field-Limiting Conductive Layers (H-Type, Höchstädter); F = Flat Galvanized Steel Wire; F = Flat Galvanized Steel Wire; R = Round Steel Wire.
7 coding systems recognise this code
Standard, worked reading and related types
Worked reading of HFFR:
HFFR: H = Halogen-Free Compound (Insulation Or Sheath, E.g. NHXH, N2XSEHRH); Older MV Cables: Field-Limiting Conductive Layers (H-Type, Höchstädter); F = Flat Galvanized Steel Wire; F = Flat Galvanized Steel Wire; R = Round Steel Wire
Related cable types: HFFR WIRE · CU/XL-HFFR/CBPT/PVC · hofr
DIN VDE 0271/0276 power cables (Germany)
| Symbol | Meaning |
|---|---|
H | Halogen-Free Compound (Insulation Or Sheath, E.g. NHXH, N2XSEHRH); Older MV Cables: Field-Limiting Conductive Layers (H-Type, Höchstädter) |
F | Flat Galvanized Steel Wire |
F | Flat Galvanized Steel Wire |
R | Round Steel Wire |
How to read a DIN VDE 0271/0276 power cables (Germany) cable code
Layer-list designation (CU/XLPE/SWA/PVC style, IEC and BS practice)
| Symbol | Meaning |
|---|---|
HFFR | Halogen-Free Flame-Retardant Compound (HFFR) |
How to read a Layer-list designation (CU/XLPE/SWA/PVC style, IEC and BS practice) cable code
China (GB / JB/T / MT cable model codes)
| Symbol | Meaning |
|---|---|
H | Communication Cable |
F | Chloroprene Rubber |
F | Chloroprene Rubber |
R | Flexible Cable |
How to read a China (GB / JB/T / MT cable model codes) cable code
NEC Article 402 (US fixture wires, NFPA 70)
| Symbol | Meaning |
|---|---|
H | 75°C Heat-Resistant Insulation (After R Or FF); ECTFE Insulation (First Letter, HF / HFF) |
FF | Fixture Wire, Flexible Stranding |
R | Heat-Resistant Rubber Or Cross-Linked Synthetic Polymer (Thermoset) |
How to read a NEC Article 402 (US fixture wires, NFPA 70) cable code
Norwegian type designation (NEK 606 offshore and Norwegian land cables)
| Symbol | Meaning |
|---|---|
H | Chlorosulphonated Polyethylene (CSP) |
F | Bedding Or Taping (Halogen-Free) |
F | Flat Steel Wire Armour |
R | Ethylene Propylene Rubber (EPR) |
How to read a Norwegian type designation (NEK 606 offshore and Norwegian land cables) cable code
NEN 3207 / KEMA (Netherlands)
| Symbol | Meaning |
|---|---|
H | With Auxiliary Conductor(s) |
FF | Ultra Fine-Wired In Flexible Cables-Class 6 |
R | Round Conductor |
VG 95218 (German Navy cables)
| Symbol | Meaning |
|---|---|
HF | Halogen Free Cable |
FR | Fire Resistant (For Duration Stated Next To This Symbol If Present) |
How to read a DIN VDE 0271/0276 power cables (Germany) cable code
A DIN VDE 0271/0276 power cables (Germany) designation (Germany) is a row of letter groups, and each group stands for one part of the cable: conductor, insulation, screen, armour, sheath, or the standard it follows. The decoder knows 51 symbols for this system.
What does h mean in a DIN VDE 0271/0276 power cables (Germany) cable code? h means Hollow Circular Conductor; or Halogen-Free Compound (Insulation Or Sheath, E.g. NHXH, N2XSEHRH); Older MV Cables: Field-Limiting Conductive Layers (H-Type, Höchstädter).
What does F mean in a DIN VDE 0271/0276 power cables (Germany) cable code? F means Flat Galvanized Steel Wire.
What does R mean in a DIN VDE 0271/0276 power cables (Germany) cable code? R means Round Steel Wire.
Fire behaviour (EU CPR)
Halogen-free compound (H). Under the CPR this shows in the additional classes: acidity a1 to a3 (EN 60754-2) and smoke s1 to s3 (EN 50399; s1a and s1b add the 3 m cube test EN 61034-2). The main class, Aca to Fca, depends on the whole construction.
Typically targeted, as declared by makers for this kind of construction in the examples this site checked (not the class of this cable):
B2ca-s1a,d0,a11-CXKH-R-J, Kablo VrchlabíCca-s1b,d1,a1FG16(O)M16, Nexans (La Triveneta Cavi)B2ca-s1a,d1,a1FG18(O)M16, Nexans (La Triveneta Cavi)DcaFXQJ, Nexans NorwayCca-s1b,d1,a1H07Z1-K, Nexans SpainB2ca-s1,d2,a1AXQJ-RMF, Prysmian Sweden (12/20 kV)B2ca-s1a,d1,a1RZ1-K (AS), Top CableCca-s1b,d1,a1RZ1FZ1-K (AS), Top Cable
Listed as sources, alphabetically by maker. No maker pays to appear here.
A CPR class is declared by the maker in its Declaration of Performance and printed on the sheath (EN 50575 cl 7). This decoder does not assign one. What the CPR classes mean →
Sources: EN 13501-6 draft and FprEN 50575:2014 final draft (drafts, not the published texts); IEC 60332-3-24:2000+A1:2008; EN 13501-3 draft A2.
Laying, sizes and datasheet: HFFR
Its sizes are in AWG and kcmil, which are not the same as the nearest mm²: compare them by area and by resistance. AWG to mm²
Work with HFFR
Who makes or stocks this cable?
Makers and stockists of this cable family appear here as sponsors for your region, each marked "Sponsored"; a listing never changes what this page says about the cable.