DFSF

DFSF is a Norwegian type designation (NEK 606 offshore and Norwegian land cables) cable designation: D = Impregnated Paper Drip Free; F = Bedding Or Taping (Halogen-Free); S = Concentric Conductor (Screen); F = Semi-Conducting PE.

2 coding systems recognise this code

Standard, worked reading and related types

Worked reading of DFSF:

  • DFSF: D = Impregnated Paper Drip Free; F = Bedding Or Taping (Halogen-Free); S = Concentric Conductor (Screen); F = Semi-Conducting PE

Norwegian type designation (NEK 606 offshore and Norwegian land cables)

SymbolMeaning
DImpregnated Paper Drip Free
FBedding Or Taping (Halogen-Free)
SConcentric Conductor (Screen)
FSemi-Conducting PE

How to read a Norwegian type designation (NEK 606 offshore and Norwegian land cables) cable code

UNE (Spain: UNE 21123 / UNE 20434)

SymbolMeaning
DEthylene-Propylene Rubber (EPR)
FHelical Galvanized Steel Tape
SSilicone Rubber
FHelical Galvanized Steel Tape

How to read a UNE (Spain: UNE 21123 / UNE 20434) cable code

How to read a Norwegian type designation (NEK 606 offshore and Norwegian land cables) cable code

A Norwegian type designation (NEK 606 offshore and Norwegian land cables) designation (Norway) is a row of letter groups, and each group stands for one part of the cable: conductor, insulation, screen, armour, sheath, or the standard it follows. The decoder knows 95 symbols for this system.

What does D mean in a Norwegian type designation (NEK 606 offshore and Norwegian land cables) cable code? D means Impregnated Paper Drip Free; or Aluminium + Plastics; or Oil Filled Cable Reinforcement (Longitudinal / Transverse).

What does F mean in a Norwegian type designation (NEK 606 offshore and Norwegian land cables) cable code? F means PE Or PP + Filling Compound; or Bedding Or Taping (Halogen-Free); or Flat Steel Wire Armour; or Semi-Conducting PE.

What does S mean in a Norwegian type designation (NEK 606 offshore and Norwegian land cables) cable code? S means Silicone Rubber; or Bedding Or Taping + Concentric Conductor; or Concentric Conductor (Screen).

Fire behaviour (EU CPR)

  • Halogen-free compound (F). Under the CPR this shows in the additional classes: acidity a1 to a3 (EN 60754-2) and smoke s1 to s3 (EN 50399; s1a and s1b add the 3 m cube test EN 61034-2). The main class, Aca to Fca, depends on the whole construction.

    Typically targeted, as declared by makers for this kind of construction in the examples this site checked (not the class of this cable):

    Listed as sources, alphabetically by maker. No maker pays to appear here.

A CPR class is declared by the maker in its Declaration of Performance and printed on the sheath (EN 50575 cl 7). This decoder does not assign one. What the CPR classes mean →

Sources: EN 13501-6 draft and FprEN 50575:2014 final draft (drafts, not the published texts); IEC 60332-3-24:2000+A1:2008; EN 13501-3 draft A2.

Laying, sizes and datasheet: DFSF

Terms on this page: bedding · conductor screen

Work with DFSF

Who makes or stocks this cable?

Makers and stockists of this cable family appear here as sponsors for your region, each marked "Sponsored"; a listing never changes what this page says about the cable.

Related cables

More Norwegian type designation (NEK 606 offshore and Norwegian land cables) designations