CEWYS
CEWYS is a China (GB / JB/T / MT cable model codes) cable designation: C = Shipboard or Marine Cable; E = Low Smoke Zero Halogen Compound; W = Oil And Open Weather Resistant; Y = Polyethylene (PE) Or Polyolefin; S = Stranded Conductor.
2 coding systems recognise this code
Standard, worked reading and related types
Standards behind these values: IEC 60502-1:2004 (edition 2.0): Power cables with extruded insulation and their accessories for rated voltages from 1 kV (Um = 1,2 kV) up to 30 kV (Um = 36 kV) - Part 1: Cables for rated voltages of 1 kV (Um = 1,2 kV) and 3 kV (Um = 3,6 kV); IEC 60228:2023 (edition 4.0): Conductors of insulated cables. How the values are sourced
Worked reading of CEWYS 1x16 0.6/1 kV:
CEWYS: C = Shipboard or Marine Cable; E = Low Smoke Zero Halogen Compound; W = Oil And Open Weather Resistant; Y = Polyethylene (PE) Or Polyolefin; S = Stranded Conductor1x16 0.6/1 kV: one core, copper 16 mm²; rated voltage 0.6/1 kV
China (GB / JB/T / MT cable model codes)
| Symbol | Meaning |
|---|---|
C | Shipboard or Marine Cable |
E | Low Smoke Zero Halogen Compound |
W | Oil And Open Weather Resistant |
Y | Polyethylene (PE) Or Polyolefin |
S | Stranded Conductor |
How to read a China (GB / JB/T / MT cable model codes) cable code
NEN 3207 / KEMA (Netherlands)
| Symbol | Meaning |
|---|---|
C | Chloroprene Rubber |
EW | With Parallel Cores (Evenwijdige Aders) |
Y | Cross-Linked Polyethylene (XLPE) |
S | Silicone Rubber |
How to read a China (GB / JB/T / MT cable model codes) cable code
A China (GB / JB/T / MT cable model codes) designation (China) is a row of letter groups, and each group stands for one part of the cable: conductor, insulation, screen, armour, sheath, or the standard it follows. The decoder knows 137 symbols for this system.
What does C mean in a China (GB / JB/T / MT cable model codes) cable code? C means Shipboard or Marine Cable; or Heavy Duty (Characteristic Letter, As In YC).
What does E mean in a China (GB / JB/T / MT cable model codes) cable code? E means Low Smoke Zero Halogen Compound.
What does W mean in a China (GB / JB/T / MT cable model codes) cable code? W means Oil And Open Weather Resistant.
What does Y mean in a China (GB / JB/T / MT cable model codes) cable code? Y means Polyethylene (PE) Or Polyolefin.
What does S mean in a China (GB / JB/T / MT cable model codes) cable code? S means Silicone Rubber; or Stranded Conductor.
Fire behaviour (EU CPR)
Halogen-free compound (E). Under the CPR this shows in the additional classes: acidity a1 to a3 (EN 60754-2) and smoke s1 to s3 (EN 50399; s1a and s1b add the 3 m cube test EN 61034-2). The main class, Aca to Fca, depends on the whole construction.
Typically targeted, as declared by makers for this kind of construction in the examples this site checked (not the class of this cable):
B2ca-s1a,d0,a11-CXKH-R-J, Kablo VrchlabíCca-s1b,d1,a1FG16(O)M16, Nexans (La Triveneta Cavi)B2ca-s1a,d1,a1FG18(O)M16, Nexans (La Triveneta Cavi)DcaFXQJ, Nexans NorwayCca-s1b,d1,a1H07Z1-K, Nexans SpainB2ca-s1,d2,a1AXQJ-RMF, Prysmian Sweden (12/20 kV)B2ca-s1a,d1,a1RZ1-K (AS), Top CableCca-s1b,d1,a1RZ1FZ1-K (AS), Top Cable
Listed as sources, alphabetically by maker. No maker pays to appear here.
A CPR class is declared by the maker in its Declaration of Performance and printed on the sheath (EN 50575 cl 7). This decoder does not assign one. What the CPR classes mean →
Sources: EN 13501-6 draft and FprEN 50575:2014 final draft (drafts, not the published texts); IEC 60332-3-24:2000+A1:2008; EN 13501-3 draft A2.
CEWYS as the cable designer builds it, 1x16 0.6/1 kV
Overall diameter 9.1 mm, about 200 kg/km. Nominal values from the standard's tables for this size, computed, not a maker's data.
| Layer | Material | Thickness, mm | Over the layer, mm |
|---|---|---|---|
| Insulation | Halogen-free (LSZH) | 0.70 | 6.3 |
| Sheath | PE | 1.4 | 9.1 |
CEWYS on a drum
The smallest drum that passes every check, for 9.1 mm and about 200 kg/km as the cable designer builds it. Drums as their makers print them; lengths are estimates: whole layers wound nested (each turn in the groove of the layer below), wound diameter 1.05 × OD, 50 mm freeboard under the flange rim. Cable makers' own tables print less, as they count aligned layers.
| Length | Drum size (its makers) | Layers | Gross weight |
|---|---|---|---|
| 500 m | KTG 6 (600 mm flange), plywood KTG drums (Europe), Bayka | 12 of 14 | 107 kg |
| 1,000 m | KTG 8 (800 mm flange), wood KTG drums (Europe), Bayka, KTG | 15 of 17 | 231–235 kg |
Barrel at least 20 × OD = 182 mm for a cable of this kind (Low voltage, single core): KTG table, the cable's datasheet wins. A load rating is the drum maker's own. A steel drum whose maker prints none is checked against the DIN 46391-4 guide load instead: 28 kN per m³ of gross winding volume.
Other lengths, drums and weights: the cable drum calculator
Load it on a truck: 1000 m on its drum in the loading planner
Laying, sizes and datasheet: CEWYS
Selling this cable? Open it in the designer and get a datasheet with your logo (Pro). Open the cable designer · See Pro
Work with CEWYS
Who makes or stocks this cable?
Makers and stockists of this cable family appear here as sponsors for your region, each marked "Sponsored"; a listing never changes what this page says about the cable.