MYLE
MYLE is a China (GB / JB/T / MT cable model codes) cable designation: M = Mining Cable; Y = Polyethylene (PE) Or Polyolefin; L = Aluminium Conductor; E = Low Smoke Zero Halogen Compound.
2 coding systems recognise this code
Standard, worked reading and related types
Worked reading of MYLE:
MYLE: M = Mining Cable; Y = Polyethylene (PE) Or Polyolefin; L = Aluminium Conductor; E = Low Smoke Zero Halogen Compound
China (GB / JB/T / MT cable model codes)
| Symbol | Meaning |
|---|---|
M | Mining Cable |
Y | Polyethylene (PE) Or Polyolefin |
L | Aluminium Conductor |
E | Low Smoke Zero Halogen Compound |
How to read a China (GB / JB/T / MT cable model codes) cable code
Norwegian type designation (NEK 606 offshore and Norwegian land cables)
| Symbol | Meaning |
|---|---|
M | Expanded PE Or PP + Filling Compound |
Y | Screen |
L | Aluminium (Laminated To Outer Jacket) |
E | Polyethylene (PE) or Polypropylene (PP) |
How to read a Norwegian type designation (NEK 606 offshore and Norwegian land cables) cable code
How to read a China (GB / JB/T / MT cable model codes) cable code
A China (GB / JB/T / MT cable model codes) designation (China) is a row of letter groups, and each group stands for one part of the cable: conductor, insulation, screen, armour, sheath, or the standard it follows. The decoder knows 137 symbols for this system.
What does M mean in a China (GB / JB/T / MT cable model codes) cable code? M means Mining Cable; or Watertight.
What does Y mean in a China (GB / JB/T / MT cable model codes) cable code? Y means Polyethylene (PE) Or Polyolefin.
What does L mean in a China (GB / JB/T / MT cable model codes) cable code? L means Aluminium Conductor; or Aluminium Sheath.
What does E mean in a China (GB / JB/T / MT cable model codes) cable code? E means Low Smoke Zero Halogen Compound.
Fire behaviour (EU CPR)
Halogen-free compound (E). Under the CPR this shows in the additional classes: acidity a1 to a3 (EN 60754-2) and smoke s1 to s3 (EN 50399; s1a and s1b add the 3 m cube test EN 61034-2). The main class, Aca to Fca, depends on the whole construction.
Typically targeted, as declared by makers for this kind of construction in the examples this site checked (not the class of this cable):
B2ca-s1a,d0,a11-CXKH-R-J, Kablo VrchlabíCca-s1b,d1,a1FG16(O)M16, Nexans (La Triveneta Cavi)B2ca-s1a,d1,a1FG18(O)M16, Nexans (La Triveneta Cavi)DcaFXQJ, Nexans NorwayCca-s1b,d1,a1H07Z1-K, Nexans SpainB2ca-s1,d2,a1AXQJ-RMF, Prysmian Sweden (12/20 kV)B2ca-s1a,d1,a1RZ1-K (AS), Top CableCca-s1b,d1,a1RZ1FZ1-K (AS), Top Cable
Listed as sources, alphabetically by maker. No maker pays to appear here.
A CPR class is declared by the maker in its Declaration of Performance and printed on the sheath (EN 50575 cl 7). This decoder does not assign one. What the CPR classes mean →
Sources: EN 13501-6 draft and FprEN 50575:2014 final draft (drafts, not the published texts); IEC 60332-3-24:2000+A1:2008; EN 13501-3 draft A2.