C12
C12 is a China (GB / JB/T / MT cable model codes) cable designation: C = Shipboard or Marine Cable; 1 = Interlocked Steel Tape Armour; 2 = PVC (Polyvinyl Chloride) Outer Sheath.
2 coding systems recognise this code
Standard, worked reading and related types
Worked reading of C12:
C12: C = Shipboard or Marine Cable; 1 = Interlocked Steel Tape Armour; 2 = PVC (Polyvinyl Chloride) Outer Sheath
China (GB / JB/T / MT cable model codes)
| Symbol | Meaning |
|---|---|
C | Shipboard or Marine Cable |
1 | Interlocked Steel Tape Armour |
2 | PVC (Polyvinyl Chloride) Outer Sheath |
How to read a China (GB / JB/T / MT cable model codes) cable code
IEEE 1580
| Symbol | Meaning |
|---|---|
C | Conductor Control Cable, 12 AWG |
How to read a China (GB / JB/T / MT cable model codes) cable code
A China (GB / JB/T / MT cable model codes) designation (China) is a row of letter groups, and each group stands for one part of the cable: conductor, insulation, screen, armour, sheath, or the standard it follows. The decoder knows 137 symbols for this system.
What does C mean in a China (GB / JB/T / MT cable model codes) cable code? C means Shipboard or Marine Cable; or Heavy Duty (Characteristic Letter, As In YC).
What does 1 mean in a China (GB / JB/T / MT cable model codes) cable code? 1 means Interlocked Steel Tape Armour; or Fibre Outer Covering (Jute Or Polypropylene Yarn Serving); or Radial Copper Tape Reinforcement (Oil-Filled Cables).
What does 2 mean in a China (GB / JB/T / MT cable model codes) cable code? 2 means PVC (Polyvinyl Chloride) Outer Sheath; or Double Steel Tape Armour; or Radial Stainless Steel Tape Reinforcement (Oil-Filled Cables).
Fire behaviour (EU CPR)
PVC sheath (2).
Typically targeted, as declared by makers for this kind of construction in the examples this site checked (not the class of this cable):
EcaN1XV-R, Ahlsell (seller)Cca-s3,d1,a3FG16OR16, Nexans (La Triveneta Cavi)EcaU1000 R2V, Nexans (La Triveneta Cavi)EcaN2XSY, Waskönig+Walter (10 kV datasheet)
Listed as sources, alphabetically by maker. No maker pays to appear here.
A CPR class is declared by the maker in its Declaration of Performance and printed on the sheath (EN 50575 cl 7). This decoder does not assign one. What the CPR classes mean →
Sources: EN 13501-6 draft and FprEN 50575:2014 final draft (drafts, not the published texts); IEC 60332-3-24:2000+A1:2008; EN 13501-3 draft A2.
Laying, sizes and datasheet: C12
Terms on this page: oversheath (outer sheath) · steel tape armour
Work with C12
Who makes or stocks this cable?
Makers and stockists of this cable family appear here as sponsors for your region, each marked "Sponsored"; a listing never changes what this page says about the cable.