A2X(F)K2Y
A2X(F)K2Y is a DIN VDE 0271/0276 power cables (Germany) cable designation: A = Aluminium Conductor; 2X = Cross-Linked Polyethylene (XLPE); (F) = Longitudinal Water Resistant Tape; K = Lead Sheath; 2Y = Polyethylene (PE).
1 coding system recognises this code
Standard, worked reading and related types
Standards behind these values: IEC 60840:2020+AMD1:2023: Power cables with extruded insulation and their accessories for rated voltages above 30 kV (Um = 36 kV) up to 150 kV (Um = 170 kV) - Test methods and requirements; IEC 60228:2023 (edition 4.0): Conductors of insulated cables. How the values are sourced
Worked reading of A2X(F)K2Y 1x630 64/110 kV:
A2X(F)K2Y: A = Aluminium Conductor; 2X = Cross-Linked Polyethylene (XLPE); (F) = Longitudinal Water Resistant Tape; K = Lead Sheath; 2Y = Polyethylene (PE)1x630 64/110 kV: one core, aluminium 630 mm²; rated voltage 64/110 kV
Related cable types: A2X(FL)2Y · A2XFF2Y · A2XS(F)2Y · A2XS(FL)2Y · A2XFY · NA2X(FL)2Y
DIN VDE 0271/0276 power cables (Germany)
| Symbol | Meaning |
|---|---|
A | Aluminium Conductor |
2X | Cross-Linked Polyethylene (XLPE) |
(F) | Longitudinal Water Resistant Tape |
K | Lead Sheath |
2Y | Polyethylene (PE) |
How to read a DIN VDE 0271/0276 power cables (Germany) cable code
How to read a DIN VDE 0271/0276 power cables (Germany) cable code
A DIN VDE 0271/0276 power cables (Germany) designation (Germany) is a row of letter groups, and each group stands for one part of the cable: conductor, insulation, screen, armour, sheath, or the standard it follows. The decoder knows 51 symbols for this system.
What does A mean in a DIN VDE 0271/0276 power cables (Germany) cable code? A means Aluminium Conductor.
What does 2X mean in a DIN VDE 0271/0276 power cables (Germany) cable code? 2X means Cross-Linked Polyethylene (XLPE).
What does (F) mean in a DIN VDE 0271/0276 power cables (Germany) cable code? (F) means Longitudinal Water Resistant Tape.
What does K mean in a DIN VDE 0271/0276 power cables (Germany) cable code? K means Lead Sheath.
What does 2Y mean in a DIN VDE 0271/0276 power cables (Germany) cable code? 2Y means Polyethylene (PE).
Fire behaviour (EU CPR)
PE sheath (2Y).
Typically targeted, as declared by makers for this kind of construction in the examples this site checked (not the class of this cable):
FcaYMeKrvaslqwd, TKFFcaNA2XS(F)2Y, Waskönig+Walter
Listed as sources, alphabetically by maker. No maker pays to appear here.
A CPR class is declared by the maker in its Declaration of Performance and printed on the sheath (EN 50575 cl 7). This decoder does not assign one. What the CPR classes mean →
Sources: EN 13501-6 draft and FprEN 50575:2014 final draft (drafts, not the published texts); IEC 60332-3-24:2000+A1:2008; EN 13501-3 draft A2.
A2X(F)K2Y as the cable designer builds it, 1x630 64/110 kV
Overall diameter 81.6 mm, about 12,410 kg/km. Nominal values from the standard's tables for this size, computed, not a maker's data.
| Layer | Material | Thickness, mm | Over the layer, mm |
|---|---|---|---|
| Conductor screen (semicon) | Semiconducting | 1.2 | 33.0 |
| Insulation | XLPE | 16.0 | 65.0 |
| Insulation screen (semicon) | Semiconducting | 1.0 | 67.0 |
| Swelling tape (water block) | Swelling | 0.50 | 68.0 |
| Metal sheath (lead or smooth aluminium) | Lead alloy | 2.8 | 73.6 |
| Sheath | PE | 4.0 | 81.6 |
A2X(F)K2Y on a drum
The smallest drum that passes every check, for 81.6 mm and about 12,410 kg/km as the cable designer builds it. Drums as their makers print them; lengths are estimates: whole layers wound nested (each turn in the groove of the layer below), wound diameter 1.05 × OD, 86 mm freeboard under the flange rim. Cable makers' own tables print less, as they count aligned layers.
| Length | Drum size (its makers) | Layers | Gross weight |
|---|---|---|---|
| 500 m | No single drum in KTG drums (Europe) takes it: the drum calculator splits it over several. | ||
| 1,000 m | No single drum in KTG drums (Europe) takes it: the drum calculator splits it over several. | ||
Barrel at least 25 × OD = 2,040 mm for a cable of this kind (High voltage (above 36 kV)): KTG table, the cable's datasheet wins. A load rating is the drum maker's own. A steel drum whose maker prints none is checked against the DIN 46391-4 guide load instead: 28 kN per m³ of gross winding volume.
Other lengths, drums and weights: the cable drum calculator
Load it on a truck: 1000 m on its drum in the loading planner
Laying, sizes and datasheet: A2X(F)K2Y
A2X(F)K2Y belongs to the family High voltage cables: the lowest laying temperature, bending radius, pulling, depth, drum handling and the test after laying, every rule with its sources. Laying and handling guide: High voltage cables
Selling this cable? Open it in the designer and get a datasheet with your logo (Pro). Open the cable designer · See Pro
Work with A2X(F)K2Y
Who makes or stocks this cable?
Makers and stockists of this cable family appear here as sponsors for your region, each marked "Sponsored"; a listing never changes what this page says about the cable.