60245 IEC 89
60245 IEC 89 is a IEC 60227 / IEC 60245 type numbers cable designation: 60245 IEC 89 = 60245 IEC 89: EPR insulated and textile braided cord for high flexibility (iron cord), 300/300 V; 60245 IEC 89 = 60245 IEC 89: EPR insulated and braided cord for applications requiring high flexibility, 300/300 V. 300/300 V; 2 or 3 cores of 0.75, 1 or 1.5 mm2, class 6 (resistance +3 %); IE4 EPR insulation 0.8 mm; textile braid; mean overall diameter 5.5 to 7.2 mm (2 x 0.75) up to 6.7 to 8.8 mm (3 x 1.5); 60 C (IEC 60245-8 cl. 5, Table 8). IEC 60245-8 (clause 5); code IEC 60245-1 Annex A.
1 coding system recognises this code
IEC 60227 / IEC 60245 type numbers
| Symbol | Meaning |
|---|---|
60245 IEC 89 | 60245 IEC 89: EPR insulated and textile braided cord for high flexibility (iron cord), 300/300 V |
60245 IEC 89 | 60245 IEC 89: EPR insulated and braided cord for applications requiring high flexibility, 300/300 V. 300/300 V; 2 or 3 cores of 0.75, 1 or 1.5 mm2, class 6 (resistance +3 %); IE4 EPR insulation 0.8 mm; textile braid; mean overall diameter 5.5 to 7.2 mm (2 x 0.75) up to 6.7 to 8.8 mm (3 x 1.5); 60 C (IEC 60245-8 cl. 5, Table 8). IEC 60245-8 (clause 5); code IEC 60245-1 Annex A |
What is 60245 IEC 89 cable?
60245 IEC 89: EPR insulated and braided cord for applications requiring high flexibility, 300/300 V. Rating: 300/300 V; 2 or 3 cores of 0.75, 1 or 1.5 mm2, class 6 (resistance +3 %); IE4 EPR insulation 0.8 mm; textile braid; mean overall diameter 5.5 to 7.2 mm (2 x 0.75) up to 6.7 to 8.8 mm (3 x 1.5); 60 C (IEC 60245-8 cl. 5, Table 8). Standard: IEC 60245-8 (clause 5); code IEC 60245-1 Annex A.
IEC 60245-8 ed. 1.2 (standard, read 2026-11-01): EPR insulated and braided cord for applications requiring high flexibility, for example iron cords (1.1, p. 5; clause 5, p. 6); 300/300 V (5.2); 2 or 3 class 6 conductors with the maximum resistance raised 3 %, plain or tinned (5.3.1); an optional separator (5.3.2); EPR insulation IE 4, extruded, 0.8 mm (5.3.3, Table 8); textile fillers, the cores and fillers twisted with a lay at most 7.5 times the diameter over the cores, conductors and cores in the same direction, a centre filler allowed (5.3.4, 5.3.5); an overall textile braid of at least 60 threads, 700 crossings per metre and 24 carriers (5.3.6, p. 6 to 7); Table 8 (p. 8): 2 x 0.75 mean overall diameter 5.5 to 7.2 mm, 2 x 1 5.7 to 7.6, 2 x 1.5 6.2 to 8.2, 3 x 0.75 5.9 to 7.7, 3 x 1 6.2 to 8.1, 3 x 1.5 6.7 to 8.8 mm; 60 C in normal use (5.5, p. 8). Amendment 2 (2011) left clauses 2 to 4 spare: the rubber and XLPVC cords 60245 IEC 86, 87 and 88, still named in IEC 60245-1:2003+A1:2007 Annex A (p. 22), have no clause in the edition held, so they have no row. IEC 60245-4:2011 clause 2 (p. 7) sends the braided cord here. Code designation (IEC 60245-1:2003+A1:2007 Annex A, p. 21 to 22): the first numeral is the basic class (0 non-sheathed for fixed wiring, 5 normal duty flexible, 6 heavy duty flexible, 7 special duty, 8 special application), the second the type within the class, so the number is read whole. The old spelling drops the 60 ('227 IEC 53' = '60227 IEC 53', IEC renumbering); Helukabel's table prints 227 / 245, EN-JV and Top Cable 60227. Core colours (IEC 60245-1:2003+A1:2007 4.1.2, p. 9): one and two cores no preferred scheme; three cores green-and-yellow, blue, brown or brown, black, grey; four cores green-and-yellow, brown, black, grey or blue, brown, black, grey; five cores green-and-yellow, blue, brown, black, grey or blue, brown, black, grey, black; above five cores by colour (green-and-yellow and blue in the outer layer) or by number (4.2). Drawn with the green-and-yellow set when the size says so (3G1.5), otherwise the set without it; two cores are drawn brown and blue (the HD 308 pair, as the standard prefers none); above five cores black numbered cores, the green-and-yellow core last. China: GB/T 5013.8-2013 is an identical adoption (IDT) of IEC 60245-8:2004 (SAMR record, checked 2026-11-09; the portal serves no text of it), so its values are this edition's.
Documents and pages the readings were taken from
- IEC 60245-8 ed. 1.2 (1998 + A1:2003 + A2:2011): clauses 2 to 4 spare, clause 5 pp. 6 to 8, Table 8 p. 8
- IEC 60245-1 ed. 4.1 (2003 + A1:2007): Annex A code designation p. 21 to 22; 4.1.2 preferred core colours p. 9, 4.2 cores by number pp. 9 to 10
IEC 60227 / IEC 60245 type numbers: how to read the cable type names
Work with 60245 IEC 89
Who makes or stocks this cable?
Makers and stockists of this cable family appear here as sponsors for your region, each marked "Sponsored"; a listing never changes what this page says about the cable.