2XFBY
2XFBY is a DIN VDE 0271/0276 power cables (Germany) cable designation: 2X = Cross-Linked Polyethylene (XLPE); F = Flat Galvanized Steel Wire; B = Steel Tape Armour; Y = Polyvinyl Chloride (PVC).
2 coding systems recognise this code
Standard, worked reading and related types
Worked reading of 2XFBY:
2XFBY: 2X = Cross-Linked Polyethylene (XLPE); F = Flat Galvanized Steel Wire; B = Steel Tape Armour; Y = Polyvinyl Chloride (PVC)
Related cable types: 2XFY
DIN VDE 0271/0276 power cables (Germany)
| Symbol | Meaning |
|---|---|
2X | Cross-Linked Polyethylene (XLPE) |
F | Flat Galvanized Steel Wire |
B | Steel Tape Armour |
Y | Polyvinyl Chloride (PVC) |
How to read a DIN VDE 0271/0276 power cables (Germany) cable code
India (IS 1554 / IS 7098 cable code)
| Symbol | Meaning |
|---|---|
2X | Cross-Linked Polyethylene (XLPE) |
F | Flat Galvanized Steel Wire (Strip) Armour |
B | Braiding, Compounding Or Varnishing |
Y | Polyvinyl Chloride (PVC) |
How to read a India (IS 1554 / IS 7098 cable code) cable code
How to read a DIN VDE 0271/0276 power cables (Germany) cable code
A DIN VDE 0271/0276 power cables (Germany) designation (Germany) is a row of letter groups, and each group stands for one part of the cable: conductor, insulation, screen, armour, sheath, or the standard it follows. The decoder knows 51 symbols for this system.
What does 2X mean in a DIN VDE 0271/0276 power cables (Germany) cable code? 2X means Cross-Linked Polyethylene (XLPE).
What does F mean in a DIN VDE 0271/0276 power cables (Germany) cable code? F means Flat Galvanized Steel Wire.
What does B mean in a DIN VDE 0271/0276 power cables (Germany) cable code? B means Steel Tape Armour.
What does Y mean in a DIN VDE 0271/0276 power cables (Germany) cable code? Y means Polyvinyl Chloride (PVC).
Fire behaviour (EU CPR)
PVC sheath (Y).
Typically targeted, as declared by makers for this kind of construction in the examples this site checked (not the class of this cable):
EcaN1XV-R, Ahlsell (seller)Cca-s3,d1,a3FG16OR16, Nexans (La Triveneta Cavi)EcaU1000 R2V, Nexans (La Triveneta Cavi)EcaN2XSY, Waskönig+Walter (10 kV datasheet)
Listed as sources, alphabetically by maker. No maker pays to appear here.
A CPR class is declared by the maker in its Declaration of Performance and printed on the sheath (EN 50575 cl 7). This decoder does not assign one. What the CPR classes mean →
Sources: EN 13501-6 draft and FprEN 50575:2014 final draft (drafts, not the published texts); IEC 60332-3-24:2000+A1:2008; EN 13501-3 draft A2.
Laying, sizes and datasheet: 2XFBY
Terms on this page: steel tape armour
Work with 2XFBY
Who makes or stocks this cable?
Makers and stockists of this cable family appear here as sponsors for your region, each marked "Sponsored"; a listing never changes what this page says about the cable.