MMJ

MMJ is een kabelaanduiding volgens SFS 5636 (Finland): M = 1st letter: plastic insulation ('muovieristetty'; fi.wikipedia 'M = Muovi'); PVC per the Reka sheet; M = 2nd letter: plastic sheath ('muovivaippa'); UV-protected PVC per the Reka sheet; J = Plastic-sheathed cable or cord ('Tarkoittaa muovivaippakaapelia/johtoa. MMJ'); MMJ = MMJ: plastic-insulated, plastic-sheathed installation cable, copper, PVC, 300/500 V; a trailing S means one core is green-yellow earth, N means none. 300/500 V, 70 C conductor, 160 C short circuit (5 s). SFS 2091, SS 424 02 19-3, NEK 535 (Reka datasheet).

1 coderingssysteem herkent deze aanduiding

SFS 5636 (Finland)

SymboolBetekenis
M1st letter: plastic insulation ('muovieristetty'; fi.wikipedia 'M = Muovi'); PVC per the Reka sheet
M2nd letter: plastic sheath ('muovivaippa'); UV-protected PVC per the Reka sheet
JPlastic-sheathed cable or cord ('Tarkoittaa muovivaippakaapelia/johtoa. MMJ')
MMJMMJ: plastic-insulated, plastic-sheathed installation cable, copper, PVC, 300/500 V; a trailing S means one core is green-yellow earth, N means none. 300/500 V, 70 C conductor, 160 C short circuit (5 s). SFS 2091, SS 424 02 19-3, NEK 535 (Reka datasheet)

Brandgedrag (EU-bouwproductenverordening, CPR)

Een CPR-klasse wordt door de fabrikant gedeclareerd in zijn prestatieverklaring en op de mantel afgedrukt (EN 50575 art. 7). Deze decoder kent geen klasse toe. Wat de CPR-klassen betekenen →

Bronnen: ontwerp EN 13501-6 en eindontwerp FprEN 50575:2014 (ontwerpen, niet de gepubliceerde teksten); IEC 60332-3-24:2000+A1:2008; ontwerp EN 13501-3 A2.