NYMH11YÖ

NYMH11YÖ è una sigla di designazione di cavo secondo Sigle di tipo DIN VDE (Germania): N = Tipo nazionale tedesco (VDE); Y = Isolante delle anime in PVC (YI2); MH = Schlauchleitung: un cavo flessibile sotto guaina; 11Y = Guaina in poliuretano (PUR), mescola 11YM1; Ö = Resistente agli oli (la guaina in poliuretano); NYMH11YÖ = NYMH11YÖ: PVC insulated flexible cord (Schlauchleitung) with an oil resistant polyurethane sheath, 300/500 V (a draft German standard). U0/U 300/500 V (clause 3). E DIN VDE 0250-407:1989-08, a draft (Entwurf), never published as a standard; seen as a draft: 2 to 5 cores 0,75 to 2,5 mm² (4.1), fine-wire copper class 5 (4.2), PVC insulation YI2 (4.3), core colours DIN VDE 0293 (4.4), stranded with a lay of at most 15 times the diameter over the lay-up, a separator and a filler allowed (4.5), sheath thermoplastic polyurethane 11YM1 (4.6); the A1 draft of 1992-06 is held and not read for this row.

1 sistema di codifica riconosce questa sigla

Sigle di tipo DIN VDE (Germania)

SimboloSignificato
NTipo nazionale tedesco (VDE)
YIsolante delle anime in PVC (YI2)
MHSchlauchleitung: un cavo flessibile sotto guaina
11YGuaina in poliuretano (PUR), mescola 11YM1
ÖResistente agli oli (la guaina in poliuretano)
NYMH11YÖNYMH11YÖ: PVC insulated flexible cord (Schlauchleitung) with an oil resistant polyurethane sheath, 300/500 V (a draft German standard). U0/U 300/500 V (clause 3). E DIN VDE 0250-407:1989-08, a draft (Entwurf), never published as a standard; seen as a draft: 2 to 5 cores 0,75 to 2,5 mm² (4.1), fine-wire copper class 5 (4.2), PVC insulation YI2 (4.3), core colours DIN VDE 0293 (4.4), stranded with a lay of at most 15 times the diameter over the lay-up, a separator and a filler allowed (4.5), sheath thermoplastic polyurethane 11YM1 (4.6); the A1 draft of 1992-06 is held and not read for this row

Che cos'è il cavo NYMH11YÖ?

NYMH11YÖ: PVC insulated flexible cord (Schlauchleitung) with an oil resistant polyurethane sheath, 300/500 V (a draft German standard). Valori nominali: U0/U 300/500 V (clause 3). Norma: E DIN VDE 0250-407:1989-08, a draft (Entwurf), never published as a standard; seen as a draft: 2 to 5 cores 0,75 to 2,5 mm² (4.1), fine-wire copper class 5 (4.2), PVC insulation YI2 (4.3), core colours DIN VDE 0293 (4.4), stranded with a lay of at most 15 times the diameter over the lay-up, a separator and a filler allowed (4.5), sheath thermoplastic polyurethane 11YM1 (4.6); the A1 draft of 1992-06 is held and not read for this row.

Documenti e pagine da cui sono tratti i dati

  • E DIN VDE 0250-407:1989-08 (draft) (clauses 1 to 4.6 p. 2)

Sigle di tipo DIN VDE (Germania): come leggere i nomi dei tipi di cavo

Lavorare con NYMH11YÖ

Chi produce o ha a stock questo cavo?

Produttori e distributori di questa famiglia di cavi compaiono qui come sponsor per la Sua regione, ciascuno segnato come "Sponsorizzato"; un annuncio non cambia mai ciò che questa pagina dice del cavo.

Cavi correlati

Altre sigle Sigle di tipo DIN VDE (Germania)

NYMH11YÖ