TECK90 3C 12 AWG 600 V

Nominal calculation, not one manufacturer's datasheet. The conductors are NEC Chapter 9 Table 8; the RW90 walls, the bond, both jackets and the armour band are the values seven makers print or give through their diameters, because CSA C22.2 No. 131 was not read. Check the datasheet before you specify or order.

By NEC Table 8 and the catalogued walls, TECK90 3C 12 AWG 600 V comes to an overall diameter of about 19.0 mm and a weight of about 350 kg/km.

Open this cable in the designer Change any layer, see it in 3D and to scale, and download it.

This size as a PDF datasheet under your brand, with Pro. See Pro

Request a quote for this cable Sent to makers of this cable family, free.

Main dimensions

ConductorCopper 12 AWG (3.3 mm²), Ø 2.1 mmNEC 2026 Chapter 9 Table 8: Class B concentric or solid diameter
InsulationXLPE 0.76 mmTECK90 RW90 XLPE insulation: 30 mil at 600 V; 45, 60, 80, 90 mil at 1000 V, as six makers print it (CSA C22.2 No. 131 not read)
Diameter over insulation3.6 mm
Core diameter3.6 mm
Overall diameter19.0 mm
Weight (approximate)350 kg/km

Layer by layer (inside out)

#LayerMaterialThickness mmØ over mmSourceHow firmly
1InsulationXLPE0.763.6 (on each core)TECK90 RW90 XLPE insulation: 30 mil at 600 V; 45, 60, 80, 90 mil at 1000 V, as six makers print it (CSA C22.2 No. 131 not read)maker catalogue value, standard text not read
2Separation tapePolyester0.108.1typical polyester tapetypical value, no rule
3Inner covering / beddingPVC1.1410.4TECK90 PVC inner jacket: 45, 60, 80, 110, 140 mil, as United Wire & Cable and Nexans print itmaker catalogue value, standard text not read
4Interlocked armourAluminium3.0516.5TECK90 interlocked aluminium armour, radial band 0.120 in (3.05 mm): derived from five makers' diameters over the armour and over the inner jacket; the strip is not printedmaker catalogue value, standard text not read
5SheathPVC1.2719.0TECK90 PVC outer jacket 50 mil: the median derived from seven makers' diameters (Southwire prints 45 to 80 mil)maker catalogue value, standard text not read

TECK90 is the CSA C22.2 No. 131 armoured cable: RW90 XLPE conductors and a bare copper bond in an outer interstice, a binder tape, a PVC inner jacket, interlocked aluminium armour and a PVC outer jacket. Checked against United Wire & Cable, Prysmian, Texcan, Nexans Canada, Shawflex, Northern Cables and Southwire: research/designer-americas/mc-teck.md in the site repository.

Materials in this cable: Copper, Aluminium, XLPE, PVC

Weight, by part

Conductors110 kg/km
Metal screens and armour70 kg/km
Insulation, semicon, tapes, fillers and sheaths170 kg/km
Total350 kg/km

Each layer's cross-section times its density; stranded conductors, laid-up cores and helical wires count 2 % longer than the cable. Densities: copper 8.89 and aluminium 2.703 g/cm³ (the values of IEC 60028 and IEC 60889); XLPE 0.92, PE 0.94, PVC 1.45, semicon 1.12, steel 7.85 g/cm³ (usual compound values).

Who makes or stocks this cable?

TECK90

The same section at other voltages