YMe

YMe is a HAR: HD 361 harmonised designation (CENELEC) cable designation: Y = Turkish TS Type For Medium And Heavy Operating Conditions (e.g. YXC7V-R); M = Mineral Insulation; E = Polyethylene (PE).

4 coding systems recognise this code

Standard, worked reading and related types

Standards behind these values: IEC 60502-1:2004 (edition 2.0): Power cables with extruded insulation and their accessories for rated voltages from 1 kV (Um = 1,2 kV) up to 30 kV (Um = 36 kV) - Part 1: Cables for rated voltages of 1 kV (Um = 1,2 kV) and 3 kV (Um = 3,6 kV); IEC 60228:2023 (edition 4.0): Conductors of insulated cables. How the values are sourced

Worked reading of YMe 3x95 0.6/1 kV:

  • YMe: Y = Turkish TS Type For Medium And Heavy Operating Conditions (e.g. YXC7V-R); M = Mineral Insulation; E = Polyethylene (PE)
  • 3x95 0.6/1 kV: 3 cores, each copper 95 mm²; rated voltage 0.6/1 kV

Related cable types: YMeK · YMeKr · YMeKrv · YMeKrva · YMeKrvas · YMeKrvasl

HAR: HD 361 harmonised designation (CENELEC)

SymbolMeaning
YTurkish TS Type For Medium And Heavy Operating Conditions (e.g. YXC7V-R)
MMineral Insulation
EPolyethylene (PE)

How to read a HAR: HD 361 harmonised designation (CENELEC) cable code

TS 621 / TSE (Turkey)

SymbolMeaning
YFlat Conductor
MConcentric Copper Conductor
EPolyethylene (PE)

How to read a TS 621 / TSE (Turkey) cable code

China (GB / JB/T / MT cable model codes)

SymbolMeaning
YPolyethylene (PE) Or Polyolefin
MWatertight
ELow Smoke Zero Halogen Compound

How to read a China (GB / JB/T / MT cable model codes) cable code

NEN 3207 / KEMA (Netherlands)

SymbolMeaning
YCross-Linked Polyethylene (XLPE)
MSolid Conductor (Massief, Class 1)
EPolyethylene (PE)

How to read a NEN 3207 / KEMA (Netherlands) cable code

How to read a HAR: HD 361 harmonised designation (CENELEC) cable code

A HAR: HD 361 harmonised designation (CENELEC) designation (Europe (CENELEC)) is a row of letter groups, and each group stands for one part of the cable: conductor, insulation, screen, armour, sheath, or the standard it follows. The decoder knows 129 symbols for this system.

What does Y mean in a HAR: HD 361 harmonised designation (CENELEC) cable code? Y means Turkish TS Type For Medium And Heavy Operating Conditions (e.g. YXC7V-R).

What does M mean in a HAR: HD 361 harmonised designation (CENELEC) cable code? M means Mineral Insulation.

What does E mean in a HAR: HD 361 harmonised designation (CENELEC) cable code? E means Polyethylene (PE).

Fire behaviour (EU CPR)

  • PE sheath (E).

    Typically targeted, as declared by makers for this kind of construction in the examples this site checked (not the class of this cable):

    Listed as sources, alphabetically by maker. No maker pays to appear here.

A CPR class is declared by the maker in its Declaration of Performance and printed on the sheath (EN 50575 cl 7). This decoder does not assign one. What the CPR classes mean →

Sources: EN 13501-6 draft and FprEN 50575:2014 final draft (drafts, not the published texts); IEC 60332-3-24:2000+A1:2008; EN 13501-3 draft A2.

YMe as the cable designer builds it, 3x95 0.6/1 kV

Overall diameter 35.9 mm, about 3,240 kg/km. Nominal values from the standard's tables for this size, computed, not a maker's data.

LayerMaterialThickness, mmOver the layer, mm
InsulationXLPE1.113.7
FillerPP29.5
Inner covering / beddingPVC1.231.9
SheathPE2.035.9

YMe on a drum

The smallest drum that passes every check, for 35.9 mm and about 3,240 kg/km as the cable designer builds it. Drums as their makers print them; lengths are estimates: whole layers wound nested (each turn in the groove of the layer below), wound diameter 1.05 × OD, 50 mm freeboard under the flange rim. Cable makers' own tables print less, as they count aligned layers.

LengthDrum size (its makers)LayersGross weight
500 mKTG 16 (1600 mm flange), wood KTG drums (Europe), Bayka, KTG7 of 101,896–1,929 kg
1,000 mKTG 20 (2000 mm flange), wood KTG drums (Europe), Bayka, KTG8 of 93,719–3,840 kg

Barrel at least 15 × OD = 539 mm for a cable of this kind (Low voltage, multi-core): KTG table, the cable's datasheet wins. A load rating is the drum maker's own. A steel drum whose maker prints none is checked against the DIN 46391-4 guide load instead: 28 kN per m³ of gross winding volume.

Other lengths, drums and weights: the cable drum calculator

Load it on a truck: 1000 m on its drum in the loading planner

Laying, sizes and datasheet: YMe

Current rating and voltage drop: One circuit, C: cable on a wall, 30 °C air: about 278 A. At that current over 100 m, three-phase 400 V, cos φ 0.9: a voltage drop of about 3.1 %. Sources: IEC 60364-5-52:2009, Table B.52.5, p. 44; IEC 60228:2023 Table 4, p. 13; IEC 60228:2023 Annex B, p. 18; IEC 60364-5-52:2009 (ed. 3.0) Annex G (informative), pp. 74 to 75 (read in the standard text) Cable size calculator: smallest section for a load, every factor shown · Voltage drop calculator: IEC 60364-5-52 method and limits

YMe belongs to the family LV XLPE power cables: the lowest laying temperature, bending radius, pulling, depth, drum handling and the test after laying, every rule with its sources. Laying and handling guide: LV XLPE power cables

Selling this cable? Open it in the designer and get a datasheet with your logo (Pro). Open the cable designer · See Pro

Work with YMe

Who makes or stocks this cable?

Makers and stockists of this cable family appear here as sponsors for your region, each marked "Sponsored"; a listing never changes what this page says about the cable.

Related cables

More HAR: HD 361 harmonised designation (CENELEC) designations

YMe