TPYC

TPYC is a JIS C 3410 shipboard cables cable designation: T = T: three cores, power and lighting; P = P: EP rubber (EPR) insulation; Y = Y: PVC sheath; C = C: galvanised steel wire braid armour; TPYC = TPYC: shipboard three-core power and lighting cable, 0.6/1 kV, EPR insulation, PVC sheath, galvanised steel wire braid. 0.6/1 kV AC, 0.9/1.5 kV DC, 1.5 to 185 mm² (Table 17, p. 33); 3.6/6 kV AC, 10 to 150 mm² (Table 35, p. 50); 6/10 kV AC, 16 to 150 mm² (Table 37, p. 52); conductor 90 °C. JIS C 3410:2010 Table 1 (p. 3) and Tables 17, 35 and 37 (pp. 33, 50, 52); built on IEC 60092-351, -353, -354, -359 and -376 (Introduction, degree MOD).

1 coding system recognises this code

JIS C 3410 shipboard cables

SymbolMeaning
TT: three cores, power and lighting
PP: EP rubber (EPR) insulation
YY: PVC sheath
CC: galvanised steel wire braid armour
TPYCTPYC: shipboard three-core power and lighting cable, 0.6/1 kV, EPR insulation, PVC sheath, galvanised steel wire braid. 0.6/1 kV AC, 0.9/1.5 kV DC, 1.5 to 185 mm² (Table 17, p. 33); 3.6/6 kV AC, 10 to 150 mm² (Table 35, p. 50); 6/10 kV AC, 16 to 150 mm² (Table 37, p. 52); conductor 90 °C. JIS C 3410:2010 Table 1 (p. 3) and Tables 17, 35 and 37 (pp. 33, 50, 52); built on IEC 60092-351, -353, -354, -359 and -376 (Introduction, degree MOD)

What is TPYC cable?

TPYC: shipboard three-core power and lighting cable, 0.6/1 kV, EPR insulation, PVC sheath, galvanised steel wire braid. Rating: 0.6/1 kV AC, 0.9/1.5 kV DC, 1.5 to 185 mm² (Table 17, p. 33); 3.6/6 kV AC, 10 to 150 mm² (Table 35, p. 50); 6/10 kV AC, 16 to 150 mm² (Table 37, p. 52); conductor 90 °C. Standard: JIS C 3410:2010 Table 1 (p. 3) and Tables 17, 35 and 37 (pp. 33, 50, 52); built on IEC 60092-351, -353, -354, -359 and -376 (Introduction, degree MOD).

Read in JIS C 3410:2010 (JSA English translation), seen: standard. Table 17 (p. 33): three cores of tinned or plain annealed stranded copper 1.5 to 185 mm²; EPR insulation 1.0 mm (up to 16 mm²) to 2.0 mm (185 mm²); PVC sheath 1.2 to 2.7 mm; steel braid wire 0.3 mm (0.4 mm from 70 mm²); PVC protective covering 0.9 to 2.0 mm; routine test 3 500 V. Table 35 (p. 50): three screened cores of 10 to 150 mm²; EPR insulation 2.5 mm; PVC sheath 1.9 to 3.0 mm; steel braid wire 0.4 mm; PVC protective covering 1.5 to 2.1 mm; routine test 12.5 kV. Table 37 (p. 52): three screened cores of 16 to 150 mm²; EPR insulation 3.4 mm; PVC sheath 2.2 to 3.1 mm; steel braid wire 0.4 mm; PVC protective covering 1.6 to 2.2 mm; routine test 21 kV. Galvanised steel braid wire 0.3 or 0.4 mm (5.11.1, Table 7, p. 19), one over one under or two over two under, coverage at least 90 % (F at least 0.573, 6.16, p. 23); braid paint and protective covering white at 150/250 V and 0.6/1 kV, red at 3.6/6 and 6/10 kV, grey for fire resistant cables (6.16 c, 6.17, p. 24). Designation (cl. 10, p. 29): the symbol, a hyphen and the conductor size in mm², for multicore cables the number of cores, for telephone cables the number of pairs ("0.6/1 kV SPYC-120", "150/250 V MPYCY-12", "150/250 V TTYC-10"). FA- (flame retardant, bunched test 7.7: char at most 2.5 m) and FR- (fire resistant, mica tape under the insulation, 6.3, IEC 60331-21 or -31, 7.8) prefix the symbol. TMC prints the same name in its catalogue (manufacturer).

Documents and pages the readings were taken from

  • JIS C 3410:2010, JSA English translation (first English edition 2011-09): Table 1 types and symbols pp. 2 to 8, Tables 2 and 3 letters pp. 8 to 9, construction Tables 17, 35 and 37 (pp. 33, 50, 52)
  • powerandcables.com

JIS C 3410 shipboard cables: how to read the cable type names

Fire behaviour (EU CPR)

A CPR class is declared by the maker in its Declaration of Performance and printed on the sheath (EN 50575 cl 7). This decoder does not assign one. What the CPR classes mean →

Sources: EN 13501-6 draft and FprEN 50575:2014 final draft (drafts, not the published texts); IEC 60332-3-24:2000+A1:2008; EN 13501-3 draft A2.

Work with TPYC

Who makes or stocks this cable?

Makers and stockists of this cable family appear here as sponsors for your region, each marked "Sponsored"; a listing never changes what this page says about the cable.

Related cables

More JIS C 3410 shipboard cables designations