TPLCY

TPLCY is a JIS C 3410 shipboard cables cable designation: T = T: three cores, power and lighting; P = P: EP rubber (EPR) insulation; L = L: lead alloy sheath; C = C: galvanised steel wire braid armour; Y = Y: PVC protective covering over the armour; TPLCY = TPLCY: shipboard three-core power and lighting cable, 0.6/1 kV, EPR insulation, lead alloy sheath, galvanised steel wire braid, PVC protective covering. 0.6/1 kV AC, 0.9/1.5 kV DC; conductor 90 °C; 1.5, 2.5 and 4 mm² (Table 19 Notes 3 and 4, p. 35). JIS C 3410:2010 Table 1 (p. 4) and Table 19 (p. 35); built on IEC 60092-351, -353, -354, -359 and -376 (Introduction, degree MOD).

1 coding system recognises this code

JIS C 3410 shipboard cables

SymbolMeaning
TT: three cores, power and lighting
PP: EP rubber (EPR) insulation
LL: lead alloy sheath
CC: galvanised steel wire braid armour
YY: PVC protective covering over the armour
TPLCYTPLCY: shipboard three-core power and lighting cable, 0.6/1 kV, EPR insulation, lead alloy sheath, galvanised steel wire braid, PVC protective covering. 0.6/1 kV AC, 0.9/1.5 kV DC; conductor 90 °C; 1.5, 2.5 and 4 mm² (Table 19 Notes 3 and 4, p. 35). JIS C 3410:2010 Table 1 (p. 4) and Table 19 (p. 35); built on IEC 60092-351, -353, -354, -359 and -376 (Introduction, degree MOD)

What is TPLCY cable?

TPLCY: shipboard three-core power and lighting cable, 0.6/1 kV, EPR insulation, lead alloy sheath, galvanised steel wire braid, PVC protective covering. Rating: 0.6/1 kV AC, 0.9/1.5 kV DC; conductor 90 °C; 1.5, 2.5 and 4 mm² (Table 19 Notes 3 and 4, p. 35). Standard: JIS C 3410:2010 Table 1 (p. 4) and Table 19 (p. 35); built on IEC 60092-351, -353, -354, -359 and -376 (Introduction, degree MOD).

Read in JIS C 3410:2010 (JSA English translation), seen: standard. Table 19 (p. 35): two or three cores of 1.5, 2.5 or 4 mm²; EPR insulation 1.0 mm; lead alloy sheath 1.0 mm (5.10.1) with bituminous compound and tape bedding (6.15); steel braid wire 0.3 mm; PVC protective covering 0.9 to 1.0 mm; routine test 3 500 V. Galvanised steel braid wire 0.3 or 0.4 mm (5.11.1, Table 7, p. 19), one over one under or two over two under, coverage at least 90 % (F at least 0.573, 6.16, p. 23); braid paint and protective covering white at 150/250 V and 0.6/1 kV, red at 3.6/6 and 6/10 kV, grey for fire resistant cables (6.16 c, 6.17, p. 24). Designation (cl. 10, p. 29): the symbol, a hyphen and the conductor size in mm², for multicore cables the number of cores, for telephone cables the number of pairs ("0.6/1 kV SPYC-120", "150/250 V MPYCY-12", "150/250 V TTYC-10"). FA- (flame retardant, bunched test 7.7: char at most 2.5 m) and FR- (fire resistant, mica tape under the insulation, 6.3, IEC 60331-21 or -31, 7.8) prefix the symbol.

Documents and pages the readings were taken from

  • JIS C 3410:2010, JSA English translation (first English edition 2011-09): Table 1 types and symbols pp. 2 to 8, Tables 2 and 3 letters pp. 8 to 9, construction Table 19 (p. 35)

JIS C 3410 shipboard cables: how to read the cable type names