THW-LS/THHW-LS
THW-LS/THHW-LS is a NOM / NMX (Mexico) cable designation: T = Thermoplastic (Termoplastico) insulation; W = Resistant to water (Resistente al agua); LS = Low smoke emission (Baja emision de humos); PVC-LS is flame-retardant, low smoke, low HCl, not halogen-free; THHW-LS = Also listed as THHW-LS: Thermoplastic high-heat water-resistant low-smoke building wire (Mexico); THW-LS = Thermoplastic water-resistant low-smoke building wire (Mexico). 600 V, 90 C dry, 75 C wet. NOM-063-SCFI; NMX-J-010-ANCE.
1 coding system recognises this code
Standard, worked reading and related types
Worked reading of THW-LS/THHW-LS:
THW-LS/THHW-LS: T = Thermoplastic (Termoplastico) insulation; W = Resistant to water (Resistente al agua); LS = Low smoke emission (Baja emision de humos); PVC-LS is flame-retardant, low smoke, low HCl, not halogen-free; THHW-LS = Also listed as THHW-LS: Thermoplastic high-heat water-resistant low-smoke building wire (Mexico); THW-LS = Thermoplastic water-resistant low-smoke building wire (Mexico). 600 V, 90 C dry, 75 C wet. NOM-063-SCFI; NMX-J-010-ANCE
Related cable types: THW-LS
NOM / NMX (Mexico)
| Symbol | Meaning |
|---|---|
T | Thermoplastic (Termoplastico) insulation |
W | Resistant to water (Resistente al agua) |
LS | Low smoke emission (Baja emision de humos); PVC-LS is flame-retardant, low smoke, low HCl, not halogen-free |
THHW-LS | Also listed as THHW-LS: Thermoplastic high-heat water-resistant low-smoke building wire (Mexico) |
THW-LS | Thermoplastic water-resistant low-smoke building wire (Mexico). 600 V, 90 C dry, 75 C wet. NOM-063-SCFI; NMX-J-010-ANCE |
What is THW-LS cable?
THW-LS: Thermoplastic water-resistant low-smoke building wire (Mexico). Rating: 600 V, 90 C dry, 75 C wet. Standard: NOM-063-SCFI; NMX-J-010-ANCE.
Relsamex (Vinanel THW-LS) gives 90 C dry and 75 C wet; the 90 C wet figure on other pages belongs to THHW-LS. Vinanel XXI is Condumex's brand. Concentric soft copper. Marks CT, SR, AF, RPI in Condelmex titles are UNVERIFIED (search snippets read CT as tray-rated, SR as sunlight resistant).
Documents and pages the readings were taken from
Fire behaviour (EU CPR)
PVC sheath (LS).
Typically targeted, as declared by makers for this kind of construction in the examples this site checked (not the class of this cable):
EcaN1XV-R, Ahlsell (seller)Cca-s3,d1,a3FG16OR16, Nexans (La Triveneta Cavi)EcaU1000 R2V, Nexans (La Triveneta Cavi)EcaN2XSY, Waskönig+Walter (10 kV datasheet)
Listed as sources, alphabetically by maker. No maker pays to appear here.
A CPR class is declared by the maker in its Declaration of Performance and printed on the sheath (EN 50575 cl 7). This decoder does not assign one. What the CPR classes mean →
Sources: EN 13501-6 draft and FprEN 50575:2014 final draft (drafts, not the published texts); IEC 60332-3-24:2000+A1:2008; EN 13501-3 draft A2.
Work with THW-LS/THHW-LS
Who makes or stocks this cable?
Makers and stockists of this cable family appear here as sponsors for your region, each marked "Sponsored"; a listing never changes what this page says about the cable.