SRCR
SRCR is a UTE (France, NF C 30-202 traditional system) cable designation: S = Flexible Cable; R = Cross-Linked Polyethylene (XLPE); C = Vulcanised Rubber (Natural Or Equivalent); R = Cross-Linked Polyethylene (XLPE).
5 coding systems recognise this code
Standard, worked reading and related types
Worked reading of SRCR:
SRCR: S = Flexible Cable; R = Cross-Linked Polyethylene (XLPE); C = Vulcanised Rubber (Natural Or Equivalent); R = Cross-Linked Polyethylene (XLPE)
Related cable types: SBCR
UTE (France, NF C 30-202 traditional system)
| Symbol | Meaning |
|---|---|
S | Flexible Cable |
R | Cross-Linked Polyethylene (XLPE) |
C | Vulcanised Rubber (Natural Or Equivalent) |
R | Cross-Linked Polyethylene (XLPE) |
How to read a UTE (France, NF C 30-202 traditional system) cable code
CEI-UNEL 35011 (Italy)
| Symbol | Meaning |
|---|---|
S | Sector Shaped Stranded Conductor |
R | PVC Compound (TI1/TI2 Quality, 70 °C) |
C | Concentric Copper Conductor |
R | PVC Compound (TI1/TI2 Quality, 70 °C) |
Norwegian type designation (NEK 606 offshore and Norwegian land cables)
| Symbol | Meaning |
|---|---|
S | Silicone Rubber |
R | Ethylene Propylene Rubber (EPR) |
C | Galvanized Steel Wire Braid |
R | Ethylene Propylene Rubber (EPR) |
How to read a Norwegian type designation (NEK 606 offshore and Norwegian land cables) cable code
UNE (Spain: UNE 21123 / UNE 20434)
| Symbol | Meaning |
|---|---|
S | Silicone Rubber |
R | Cross-Linked Polyethylene (XLPE) |
C | Concentric Copper Conductor |
R | Cross-Linked Polyethylene (XLPE) |
NEN 3207 / KEMA (Netherlands)
| Symbol | Meaning |
|---|---|
S | Silicone Rubber |
R | Vulcanised Rubber (Natural, SBR Or EPR, 60 °C) |
C | Chloroprene Rubber |
R | Vulcanised Rubber (Natural, SBR Or EPR, 60 °C) |
How to read a UTE (France, NF C 30-202 traditional system) cable code
A UTE (France, NF C 30-202 traditional system) designation (France) is a row of letter groups, and each group stands for one part of the cable: conductor, insulation, screen, armour, sheath, or the standard it follows. The decoder knows 30 symbols for this system.
What does S mean in a UTE (France, NF C 30-202 traditional system) cable code? S means Flexible Cable.
What does R mean in a UTE (France, NF C 30-202 traditional system) cable code? R means Cross-Linked Polyethylene (XLPE).
What does C mean in a UTE (France, NF C 30-202 traditional system) cable code? C means Vulcanised Rubber (Natural Or Equivalent).
Fire behaviour (EU CPR)
PE sheath (R).
Typically targeted, as declared by makers for this kind of construction in the examples this site checked (not the class of this cable):
FcaYMeKrvaslqwd, TKFFcaNA2XS(F)2Y, Waskönig+Walter
Listed as sources, alphabetically by maker. No maker pays to appear here.
A CPR class is declared by the maker in its Declaration of Performance and printed on the sheath (EN 50575 cl 7). This decoder does not assign one. What the CPR classes mean →
Sources: EN 13501-6 draft and FprEN 50575:2014 final draft (drafts, not the published texts); IEC 60332-3-24:2000+A1:2008; EN 13501-3 draft A2.
Work with SRCR
Who makes or stocks this cable?
Makers and stockists of this cable family appear here as sponsors for your region, each marked "Sponsored"; a listing never changes what this page says about the cable.
Related cables
More UTE (France, NF C 30-202 traditional system) designations