SRCR

SRCR is a UTE (France, NF C 30-202 traditional system) cable designation: S = Flexible Cable; R = Cross-Linked Polyethylene (XLPE); C = Vulcanised Rubber (Natural Or Equivalent); R = Cross-Linked Polyethylene (XLPE).

5 coding systems recognise this code

Standard, worked reading and related types

Worked reading of SRCR:

  • SRCR: S = Flexible Cable; R = Cross-Linked Polyethylene (XLPE); C = Vulcanised Rubber (Natural Or Equivalent); R = Cross-Linked Polyethylene (XLPE)

Related cable types: SBCR

UTE (France, NF C 30-202 traditional system)

SymbolMeaning
SFlexible Cable
RCross-Linked Polyethylene (XLPE)
CVulcanised Rubber (Natural Or Equivalent)
RCross-Linked Polyethylene (XLPE)

How to read a UTE (France, NF C 30-202 traditional system) cable code

CEI-UNEL 35011 (Italy)

SymbolMeaning
SSector Shaped Stranded Conductor
RPVC Compound (TI1/TI2 Quality, 70 °C)
CConcentric Copper Conductor
RPVC Compound (TI1/TI2 Quality, 70 °C)

How to read a CEI-UNEL 35011 (Italy) cable code

Norwegian type designation (NEK 606 offshore and Norwegian land cables)

SymbolMeaning
SSilicone Rubber
REthylene Propylene Rubber (EPR)
CGalvanized Steel Wire Braid
REthylene Propylene Rubber (EPR)

How to read a Norwegian type designation (NEK 606 offshore and Norwegian land cables) cable code

UNE (Spain: UNE 21123 / UNE 20434)

SymbolMeaning
SSilicone Rubber
RCross-Linked Polyethylene (XLPE)
CConcentric Copper Conductor
RCross-Linked Polyethylene (XLPE)

How to read a UNE (Spain: UNE 21123 / UNE 20434) cable code

NEN 3207 / KEMA (Netherlands)

SymbolMeaning
SSilicone Rubber
RVulcanised Rubber (Natural, SBR Or EPR, 60 °C)
CChloroprene Rubber
RVulcanised Rubber (Natural, SBR Or EPR, 60 °C)

How to read a NEN 3207 / KEMA (Netherlands) cable code

How to read a UTE (France, NF C 30-202 traditional system) cable code

A UTE (France, NF C 30-202 traditional system) designation (France) is a row of letter groups, and each group stands for one part of the cable: conductor, insulation, screen, armour, sheath, or the standard it follows. The decoder knows 30 symbols for this system.

What does S mean in a UTE (France, NF C 30-202 traditional system) cable code? S means Flexible Cable.

What does R mean in a UTE (France, NF C 30-202 traditional system) cable code? R means Cross-Linked Polyethylene (XLPE).

What does C mean in a UTE (France, NF C 30-202 traditional system) cable code? C means Vulcanised Rubber (Natural Or Equivalent).

Fire behaviour (EU CPR)

  • PE sheath (R).

    Typically targeted, as declared by makers for this kind of construction in the examples this site checked (not the class of this cable):

    Listed as sources, alphabetically by maker. No maker pays to appear here.

A CPR class is declared by the maker in its Declaration of Performance and printed on the sheath (EN 50575 cl 7). This decoder does not assign one. What the CPR classes mean →

Sources: EN 13501-6 draft and FprEN 50575:2014 final draft (drafts, not the published texts); IEC 60332-3-24:2000+A1:2008; EN 13501-3 draft A2.