SPYC
SPYC is a JIS C 3410 shipboard cables cable designation: S = S: single core, power and lighting; P = P: EP rubber (EPR) insulation; Y = Y: PVC sheath; C = C: galvanised steel wire braid armour; SPYC = SPYC: shipboard single-core power and lighting cable, 0.6/1 kV, EPR insulation, PVC sheath, galvanised steel wire braid. 0.6/1 kV AC, 0.9/1.5 kV DC; conductor 90 °C; 1.5 to 300 mm² (Table 15 Notes 3 and 4, p. 31). JIS C 3410:2010 Table 1 (p. 2) and Table 15 (p. 31); built on IEC 60092-351, -353, -354, -359 and -376 (Introduction, degree MOD).
1 coding system recognises this code
JIS C 3410 shipboard cables
| Symbol | Meaning |
|---|---|
S | S: single core, power and lighting |
P | P: EP rubber (EPR) insulation |
Y | Y: PVC sheath |
C | C: galvanised steel wire braid armour |
SPYC | SPYC: shipboard single-core power and lighting cable, 0.6/1 kV, EPR insulation, PVC sheath, galvanised steel wire braid. 0.6/1 kV AC, 0.9/1.5 kV DC; conductor 90 °C; 1.5 to 300 mm² (Table 15 Notes 3 and 4, p. 31). JIS C 3410:2010 Table 1 (p. 2) and Table 15 (p. 31); built on IEC 60092-351, -353, -354, -359 and -376 (Introduction, degree MOD) |
What is SPYC cable?
SPYC: shipboard single-core power and lighting cable, 0.6/1 kV, EPR insulation, PVC sheath, galvanised steel wire braid. Rating: 0.6/1 kV AC, 0.9/1.5 kV DC; conductor 90 °C; 1.5 to 300 mm² (Table 15 Notes 3 and 4, p. 31). Standard: JIS C 3410:2010 Table 1 (p. 2) and Table 15 (p. 31); built on IEC 60092-351, -353, -354, -359 and -376 (Introduction, degree MOD).
Read in JIS C 3410:2010 (JSA English translation), seen: standard. Table 15 (p. 31): tinned or plain annealed stranded copper 1.5 to 300 mm²; EPR insulation 1.0 mm (up to 16 mm²) to 2.4 mm (300 mm²); PVC sheath 1.0 to 1.9 mm; galvanised steel wire braid of 0.3 mm wire (0.4 mm at 300 mm²); PVC protective covering 0.8 to 1.4 mm; routine test 3 500 V. Galvanised steel braid wire 0.3 or 0.4 mm (5.11.1, Table 7, p. 19), one over one under or two over two under, coverage at least 90 % (F at least 0.573, 6.16, p. 23); braid paint and protective covering white at 150/250 V and 0.6/1 kV, red at 3.6/6 and 6/10 kV, grey for fire resistant cables (6.16 c, 6.17, p. 24). Designation (cl. 10, p. 29): the symbol, a hyphen and the conductor size in mm², for multicore cables the number of cores, for telephone cables the number of pairs ("0.6/1 kV SPYC-120", "150/250 V MPYCY-12", "150/250 V TTYC-10"). FA- (flame retardant, bunched test 7.7: char at most 2.5 m) and FR- (fire resistant, mica tape under the insulation, 6.3, IEC 60331-21 or -31, 7.8) prefix the symbol. TMC prints the same name in its catalogue (manufacturer).
Documents and pages the readings were taken from
- JIS C 3410:2010, JSA English translation (first English edition 2011-09): Table 1 types and symbols pp. 2 to 8, Tables 2 and 3 letters pp. 8 to 9, construction Table 15 (p. 31)
- powerandcables.com
JIS C 3410 shipboard cables: how to read the cable type names
Fire behaviour (EU CPR)
PVC sheath (Y).
Typically targeted, as declared by makers for this kind of construction in the examples this site checked (not the class of this cable):
EcaN1XV-R, Ahlsell (seller)Cca-s3,d1,a3FG16OR16, Nexans (La Triveneta Cavi)EcaU1000 R2V, Nexans (La Triveneta Cavi)EcaN2XSY, Waskönig+Walter (10 kV datasheet)
Listed as sources, alphabetically by maker. No maker pays to appear here.
A CPR class is declared by the maker in its Declaration of Performance and printed on the sheath (EN 50575 cl 7). This decoder does not assign one. What the CPR classes mean →
Sources: EN 13501-6 draft and FprEN 50575:2014 final draft (drafts, not the published texts); IEC 60332-3-24:2000+A1:2008; EN 13501-3 draft A2.