PVC-FRA
PVC-FRA is a UTE (France, NF C 30-202 traditional system) cable designation: P = Lead Sheath; V = Polyvinyl Chloride (PVC); C = Vulcanised Rubber (Natural Or Equivalent); F = Steel Tape Armour; R = Cross-Linked Polyethylene (XLPE); A = Aluminium Conductor.
1 coding system recognises this code
Standard, worked reading and related types
Worked reading of PVC-FRA:
PVC-FRA: P = Lead Sheath; V = Polyvinyl Chloride (PVC); C = Vulcanised Rubber (Natural Or Equivalent); F = Steel Tape Armour; R = Cross-Linked Polyethylene (XLPE); A = Aluminium Conductor
UTE (France, NF C 30-202 traditional system)
| Symbol | Meaning |
|---|---|
P | Lead Sheath |
V | Polyvinyl Chloride (PVC) |
C | Vulcanised Rubber (Natural Or Equivalent) |
F | Steel Tape Armour |
R | Cross-Linked Polyethylene (XLPE) |
A | Aluminium Conductor |
How to read a UTE (France, NF C 30-202 traditional system) cable code
How to read a UTE (France, NF C 30-202 traditional system) cable code
A UTE (France, NF C 30-202 traditional system) designation (France) is a row of letter groups, and each group stands for one part of the cable: conductor, insulation, screen, armour, sheath, or the standard it follows. The decoder knows 30 symbols for this system.
What does P mean in a UTE (France, NF C 30-202 traditional system) cable code? P means Lead Sheath.
What does V mean in a UTE (France, NF C 30-202 traditional system) cable code? V means Polyvinyl Chloride (PVC).
What does C mean in a UTE (France, NF C 30-202 traditional system) cable code? C means Vulcanised Rubber (Natural Or Equivalent).
What does F mean in a UTE (France, NF C 30-202 traditional system) cable code? F means Steel Tape Armour.
What does R mean in a UTE (France, NF C 30-202 traditional system) cable code? R means Cross-Linked Polyethylene (XLPE).
What does A mean in a UTE (France, NF C 30-202 traditional system) cable code? A means Aluminium Conductor.
Fire behaviour (EU CPR)
PE sheath (R).
Typically targeted, as declared by makers for this kind of construction in the examples this site checked (not the class of this cable):
FcaYMeKrvaslqwd, TKFFcaNA2XS(F)2Y, Waskönig+Walter
Listed as sources, alphabetically by maker. No maker pays to appear here.
A CPR class is declared by the maker in its Declaration of Performance and printed on the sheath (EN 50575 cl 7). This decoder does not assign one. What the CPR classes mean →
Sources: EN 13501-6 draft and FprEN 50575:2014 final draft (drafts, not the published texts); IEC 60332-3-24:2000+A1:2008; EN 13501-3 draft A2.
Laying, sizes and datasheet: PVC-FRA