PP 40

PP 40 is a JUS / SRPS / HRN N.C0.006 type names (former Yugoslavia) cable designation: P = PVC insulation; P = PVC sheath; 40 = 40: concentric copper conductor of copper wires with a copper tape counter-helix; PP 40 = PP 40: PVC-insulated, PVC-sheathed power cable, 0,6/1 kV (NYCY, NAYCY; GOST ВВГЭ, АВВГЭ); aluminium conductors: PP 40-A. 0,6/1 kV, test voltage 3,5 kV (Novkabel). SRPS N.C5.220.

1 coding system recognises this code

JUS / SRPS / HRN N.C0.006 type names (former Yugoslavia)

SymbolMeaning
PPVC insulation
PPVC sheath
4040: concentric copper conductor of copper wires with a copper tape counter-helix
PP 40PP 40: PVC-insulated, PVC-sheathed power cable, 0,6/1 kV (NYCY, NAYCY; GOST ВВГЭ, АВВГЭ); aluminium conductors: PP 40-A. 0,6/1 kV, test voltage 3,5 kV (Novkabel). SRPS N.C5.220

What is PP 40 cable?

PP 40: PVC-insulated, PVC-sheathed power cable, 0,6/1 kV (NYCY, NAYCY; GOST ВВГЭ, АВВГЭ); aluminium conductors: PP 40-A. Rating: 0,6/1 kV, test voltage 3,5 kV (Novkabel). Standard: SRPS N.C5.220.

Novkabel pdf p.9: 'PP 40, PP 40-A', NYCY, NAYCY; GOST ВВГЭ, АВВГЭ; concentric conductor: 'wrapped annealed copper wires with contra-helical annealed copper tape or wrapped copper tape' under the PVC sheath; Kabeltrade: NYCY, NYCWY = PP40. Letters per the Split university text, Tablica 1.3 'Nacin oznacavanja energetskih kabela' (HRN N.C0.006 against HD 603 S1 / HD 620 S1): P = PVC insulation or sheath (HD Y), X = XLPE (2X), Y = green-yellow protective conductor (HD J), H = semiconducting layers round the insulation, E = PE sheath (2Y), Eh = semiconducting PE sheath, 00 = no mechanical protection, 44 = round steel wire armour, 49 = watertight electrical protection (S(F)), 91 = outer protective covering, A = aluminium; OJ / OV / SJ / SV = round solid / round stranded / sector solid / sector stranded conductor (RE / RM / SE / SM). The other two-digit codes are read off the Novkabel catalogue, which prints each SRPS name beside its VDE / HD and GOST twin.

Documents and pages the readings were taken from

JUS / SRPS / HRN N.C0.006 type names (former Yugoslavia): how to read the cable type names

Fire behaviour (EU CPR)

A CPR class is declared by the maker in its Declaration of Performance and printed on the sheath (EN 50575 cl 7). This decoder does not assign one. What the CPR classes mean →

Sources: EN 13501-6 draft and FprEN 50575:2014 final draft (drafts, not the published texts); IEC 60332-3-24:2000+A1:2008; EN 13501-3 draft A2.