NYKYRY
NYKYRY is a DIN VDE 0271/0276 power cables (Germany) cable designation: N = VDE Standard; Y = Polyvinyl Chloride (PVC); K = Lead Sheath; Y = Polyvinyl Chloride (PVC); R = Round Steel Wire; Y = Polyvinyl Chloride (PVC).
2 coding systems recognise this code
Standard, worked reading and related types
Worked reading of NYKYRY:
NYKYRY: N = VDE Standard; Y = Polyvinyl Chloride (PVC); K = Lead Sheath; Y = Polyvinyl Chloride (PVC); R = Round Steel Wire; Y = Polyvinyl Chloride (PVC)
Related cable types: nykyby · NYRY · NYYHY · NYCYBY · NYKY-J · NYY-r
DIN VDE 0271/0276 power cables (Germany)
| Symbol | Meaning |
|---|---|
N | VDE Standard |
Y | Polyvinyl Chloride (PVC) |
K | Lead Sheath |
Y | Polyvinyl Chloride (PVC) |
R | Round Steel Wire |
Y | Polyvinyl Chloride (PVC) |
How to read a DIN VDE 0271/0276 power cables (Germany) cable code
ZN-TF-500 (Poland, MV cables)
| Symbol | Meaning |
|---|---|
N | Low Smoke Zero Halogen Compound |
Y | Polyvinyl Chloride (PVC) Sheath |
K | Cable |
Y | Polyvinyl Chloride (PVC) Sheath |
R | Radially Sealed (Al/Copolymer Tape Bonded To The Sheath) |
Y | Polyvinyl Chloride (PVC) Sheath |
How to read a DIN VDE 0271/0276 power cables (Germany) cable code
A DIN VDE 0271/0276 power cables (Germany) designation (Germany) is a row of letter groups, and each group stands for one part of the cable: conductor, insulation, screen, armour, sheath, or the standard it follows. The decoder knows 51 symbols for this system.
What does N mean in a DIN VDE 0271/0276 power cables (Germany) cable code? N means VDE Standard.
What does Y mean in a DIN VDE 0271/0276 power cables (Germany) cable code? Y means Polyvinyl Chloride (PVC).
What does K mean in a DIN VDE 0271/0276 power cables (Germany) cable code? K means Lead Sheath.
What does R mean in a DIN VDE 0271/0276 power cables (Germany) cable code? R means Round Steel Wire.
Fire behaviour (EU CPR)
PVC sheath (Y).
Typically targeted, as declared by makers for this kind of construction in the examples this site checked (not the class of this cable):
EcaN1XV-R, Ahlsell (seller)Cca-s3,d1,a3FG16OR16, Nexans (La Triveneta Cavi)EcaU1000 R2V, Nexans (La Triveneta Cavi)EcaN2XSY, Waskönig+Walter (10 kV datasheet)
Listed as sources, alphabetically by maker. No maker pays to appear here.
A CPR class is declared by the maker in its Declaration of Performance and printed on the sheath (EN 50575 cl 7). This decoder does not assign one. What the CPR classes mean →
Sources: EN 13501-6 draft and FprEN 50575:2014 final draft (drafts, not the published texts); IEC 60332-3-24:2000+A1:2008; EN 13501-3 draft A2.
Work with NYKYRY
Who makes or stocks this cable?
Makers and stockists of this cable family appear here as sponsors for your region, each marked "Sponsored"; a listing never changes what this page says about the cable.