NXRH

NXRH is a China (GB / JB/T / MT cable model codes) cable designation: N = Nylon Jacket; X = Natural Or Styrene-Butadiene Rubber; R = Flexible Cable; H = Rubber Sheath; Chlorosulphonated Polyethylene (CSM) Sheath In Marine Cables.

7 coding systems recognise this code

Standard, worked reading and related types

Standards behind these values: IEC 60502-1:2004 (edition 2.0): Power cables with extruded insulation and their accessories for rated voltages from 1 kV (Um = 1,2 kV) up to 30 kV (Um = 36 kV) - Part 1: Cables for rated voltages of 1 kV (Um = 1,2 kV) and 3 kV (Um = 3,6 kV); IEC 60502-2:2014 (edition 3.0): Power cables with extruded insulation and their accessories for rated voltages from 1 kV (Um = 1,2 kV) up to 30 kV (Um = 36 kV) - Part 2: Cables for rated voltages from 6 kV (Um = 7,2 kV) up to 30 kV (Um = 36 kV); IEC 60228:2023 (edition 4.0): Conductors of insulated cables. How the values are sourced

Worked reading of NXRH 4x16 0.6/1 kV:

  • NXRH: N = Nylon Jacket; X = Natural Or Styrene-Butadiene Rubber; R = Flexible Cable; H = Rubber Sheath; Chlorosulphonated Polyethylene (CSM) Sheath In Marine Cables
  • 4x16 0.6/1 kV: 4 cores, each copper 16 mm²; rated voltage 0.6/1 kV

Related cable types: N2XRH · NXMH · 2xrh · nxh · nxhh

China (GB / JB/T / MT cable model codes)

SymbolMeaning
NNylon Jacket
XNatural Or Styrene-Butadiene Rubber
RFlexible Cable
HRubber Sheath; Chlorosulphonated Polyethylene (CSM) Sheath In Marine Cables

How to read a China (GB / JB/T / MT cable model codes) cable code

NEC Article 310 (US building wire, NFPA 70)

SymbolMeaning
NNylon Jacket
XCross-Linked Polymer Insulation
RThermoset Insulation
H75°C Insulation

How to read a NEC Article 310 (US building wire, NFPA 70) cable code

NEC Article 402 (US fixture wires, NFPA 70)

SymbolMeaning
NNylon Jacket
XCross-Linked Polyolefin Insulation
RHeat-Resistant Rubber Or Cross-Linked Synthetic Polymer (Thermoset)
H75°C Heat-Resistant Insulation (After R Or FF); ECTFE Insulation (First Letter, HF / HFF)

How to read a NEC Article 402 (US fixture wires, NFPA 70) cable code

Norwegian type designation (NEK 606 offshore and Norwegian land cables)

SymbolMeaning
NImpregnated Paper
XNo Bedding Or Equivalent
RSteel Wires (Round) + Filling Compound
HChlorosulphonated Polyethylene (CSP) (Nexans key: or CPE)

How to read a Norwegian type designation (NEK 606 offshore and Norwegian land cables) cable code

ZN-TF-500 (Poland, MV cables)

SymbolMeaning
NLow Smoke Zero Halogen Compound
XPolyethylene (PE) Sheath
RRadially Sealed (Al/Copolymer Tape Bonded To The Sheath)
HCable With Radial Field (Screened Cores, Medium Voltage)

How to read a ZN-TF-500 (Poland, MV cables) cable code

Swiss cable codes (ASE/SEV wire codes and power cable codes)

SymbolMeaning
NHalogen-Free Thermoplastic Sheath (PE Only)
XCross-Linked Polyethylene (XLPE)
RRound Steel Wire
HCable With Radial Electric Field (Höchstädter Type)

How to read a Swiss cable codes (ASE/SEV wire codes and power cable codes) cable code

UNE (Spain: UNE 21123 / UNE 20434)

SymbolMeaning
NChloroprene Rubber
XCross-Linked Polyethylene (XLPE)
RHCross-Linked Polyethylene (XLPE)

How to read a UNE (Spain: UNE 21123 / UNE 20434) cable code

How to read a China (GB / JB/T / MT cable model codes) cable code

A China (GB / JB/T / MT cable model codes) designation (China) is a row of letter groups, and each group stands for one part of the cable: conductor, insulation, screen, armour, sheath, or the standard it follows. The decoder knows 137 symbols for this system.

What does N mean in a China (GB / JB/T / MT cable model codes) cable code? N means Fire Resistant (For Duration Stated Next To This Symbol If Present); or Nylon Jacket.

What does X mean in a China (GB / JB/T / MT cable model codes) cable code? X means Natural Or Styrene-Butadiene Rubber.

What does R mean in a China (GB / JB/T / MT cable model codes) cable code? R means Flexible Cable.

What does H mean in a China (GB / JB/T / MT cable model codes) cable code? H means Communication Cable; or Cold Resistant; or Rubber Sheath; Chlorosulphonated Polyethylene (CSM) Sheath In Marine Cables.

Fire behaviour (EU CPR)

  • PE sheath (H).

    Typically targeted, as declared by makers for this kind of construction in the examples this site checked (not the class of this cable):

    Listed as sources, alphabetically by maker. No maker pays to appear here.

A CPR class is declared by the maker in its Declaration of Performance and printed on the sheath (EN 50575 cl 7). This decoder does not assign one. What the CPR classes mean →

Sources: EN 13501-6 draft and FprEN 50575:2014 final draft (drafts, not the published texts); IEC 60332-3-24:2000+A1:2008; EN 13501-3 draft A2.

NXRH as the cable designer builds it, 4x16 0.6/1 kV

Overall diameter 26.4 mm, about 1,700 kg/km. Nominal values from the standard's tables for this size, computed, not a maker's data.

LayerMaterialThickness, mmOver the layer, mm
InsulationXLPE0.706.3
FillerPP15.2
Inner covering / beddingHalogen-free (LSZH)1.017.2
SheathHalogen-free (LSZH)1.219.6
Wire armourSteel40 × 1.6022.8
SheathHalogen-free (LSZH)1.826.4

NXRH on a drum

The smallest drum that passes every check, for 26.4 mm and about 1,700 kg/km as the cable designer builds it. Drums as their makers print them; lengths are estimates: whole layers wound nested (each turn in the groove of the layer below), wound diameter 1.05 × OD, 50 mm freeboard under the flange rim. Cable makers' own tables print less, as they count aligned layers.

LengthDrum size (its makers)LayersGross weight
500 mKTG 12 (1250 mm flange), wood KTG drums (Europe), Bayka, KTG9 of 10994–1,015 kg
1,000 mKTG 16 (1600 mm flange), wood KTG drums (Europe), Bayka, KTG11 of 141,976–2,009 kg

Barrel at least 15 × OD = 396 mm for a cable of this kind (Low voltage, multi-core): KTG table, the cable's datasheet wins. A load rating is the drum maker's own. A steel drum whose maker prints none is checked against the DIN 46391-4 guide load instead: 28 kN per m³ of gross winding volume.

Other lengths, drums and weights: the cable drum calculator

Load it on a truck: 1000 m on its drum in the loading planner

Laying, sizes and datasheet: NXRH

Current rating and voltage drop: One circuit, C: cable on a wall, 30 °C air: about 96 A. At that current over 100 m, three-phase 400 V, cos φ 0.9: a voltage drop of about 5.6 %. Sources: IEC 60364-5-52:2009, Table B.52.5, p. 44; IEC 60228:2023 Table 4, p. 13; IEC 60228:2023 Annex B, p. 18; IEC 60364-5-52:2009 (ed. 3.0) Annex G (informative), pp. 74 to 75 (read in the standard text) Cable size calculator: smallest section for a load, every factor shown · Voltage drop calculator: IEC 60364-5-52 method and limits

NXRH belongs to the family LV armoured cables: the lowest laying temperature, bending radius, pulling, depth, drum handling and the test after laying, every rule with its sources. Laying and handling guide: LV armoured cables

Its sizes are in AWG and kcmil, which are not the same as the nearest mm²: compare them by area and by resistance. AWG to mm²

Selling this cable? Open it in the designer and get a datasheet with your logo (Pro). Open the cable designer · See Pro

Work with NXRH

Who makes or stocks this cable?

Makers and stockists of this cable family appear here as sponsors for your region, each marked "Sponsored"; a listing never changes what this page says about the cable.

Related cables

More China (GB / JB/T / MT cable model codes) designations