NXRH
NXRH is a China (GB / JB/T / MT cable model codes) cable designation: N = Nylon Jacket; X = Natural Or Styrene-Butadiene Rubber; R = Flexible Cable; H = Rubber Sheath; Chlorosulphonated Polyethylene (CSM) Sheath In Marine Cables.
7 coding systems recognise this code
Standard, worked reading and related types
Standards behind these values: IEC 60502-1:2004 (edition 2.0): Power cables with extruded insulation and their accessories for rated voltages from 1 kV (Um = 1,2 kV) up to 30 kV (Um = 36 kV) - Part 1: Cables for rated voltages of 1 kV (Um = 1,2 kV) and 3 kV (Um = 3,6 kV); IEC 60502-2:2014 (edition 3.0): Power cables with extruded insulation and their accessories for rated voltages from 1 kV (Um = 1,2 kV) up to 30 kV (Um = 36 kV) - Part 2: Cables for rated voltages from 6 kV (Um = 7,2 kV) up to 30 kV (Um = 36 kV); IEC 60228:2023 (edition 4.0): Conductors of insulated cables. How the values are sourced
Worked reading of NXRH 4x16 0.6/1 kV:
NXRH: N = Nylon Jacket; X = Natural Or Styrene-Butadiene Rubber; R = Flexible Cable; H = Rubber Sheath; Chlorosulphonated Polyethylene (CSM) Sheath In Marine Cables4x16 0.6/1 kV: 4 cores, each copper 16 mm²; rated voltage 0.6/1 kV
China (GB / JB/T / MT cable model codes)
| Symbol | Meaning |
|---|---|
N | Nylon Jacket |
X | Natural Or Styrene-Butadiene Rubber |
R | Flexible Cable |
H | Rubber Sheath; Chlorosulphonated Polyethylene (CSM) Sheath In Marine Cables |
How to read a China (GB / JB/T / MT cable model codes) cable code
NEC Article 310 (US building wire, NFPA 70)
| Symbol | Meaning |
|---|---|
N | Nylon Jacket |
X | Cross-Linked Polymer Insulation |
R | Thermoset Insulation |
H | 75°C Insulation |
How to read a NEC Article 310 (US building wire, NFPA 70) cable code
NEC Article 402 (US fixture wires, NFPA 70)
| Symbol | Meaning |
|---|---|
N | Nylon Jacket |
X | Cross-Linked Polyolefin Insulation |
R | Heat-Resistant Rubber Or Cross-Linked Synthetic Polymer (Thermoset) |
H | 75°C Heat-Resistant Insulation (After R Or FF); ECTFE Insulation (First Letter, HF / HFF) |
How to read a NEC Article 402 (US fixture wires, NFPA 70) cable code
Norwegian type designation (NEK 606 offshore and Norwegian land cables)
| Symbol | Meaning |
|---|---|
N | Impregnated Paper |
X | No Bedding Or Equivalent |
R | Steel Wires (Round) + Filling Compound |
H | Chlorosulphonated Polyethylene (CSP) (Nexans key: or CPE) |
How to read a Norwegian type designation (NEK 606 offshore and Norwegian land cables) cable code
ZN-TF-500 (Poland, MV cables)
| Symbol | Meaning |
|---|---|
N | Low Smoke Zero Halogen Compound |
X | Polyethylene (PE) Sheath |
R | Radially Sealed (Al/Copolymer Tape Bonded To The Sheath) |
H | Cable With Radial Field (Screened Cores, Medium Voltage) |
Swiss cable codes (ASE/SEV wire codes and power cable codes)
| Symbol | Meaning |
|---|---|
N | Halogen-Free Thermoplastic Sheath (PE Only) |
X | Cross-Linked Polyethylene (XLPE) |
R | Round Steel Wire |
H | Cable With Radial Electric Field (Höchstädter Type) |
How to read a Swiss cable codes (ASE/SEV wire codes and power cable codes) cable code
UNE (Spain: UNE 21123 / UNE 20434)
| Symbol | Meaning |
|---|---|
N | Chloroprene Rubber |
X | Cross-Linked Polyethylene (XLPE) |
RH | Cross-Linked Polyethylene (XLPE) |
How to read a China (GB / JB/T / MT cable model codes) cable code
A China (GB / JB/T / MT cable model codes) designation (China) is a row of letter groups, and each group stands for one part of the cable: conductor, insulation, screen, armour, sheath, or the standard it follows. The decoder knows 137 symbols for this system.
What does N mean in a China (GB / JB/T / MT cable model codes) cable code? N means Fire Resistant (For Duration Stated Next To This Symbol If Present); or Nylon Jacket.
What does X mean in a China (GB / JB/T / MT cable model codes) cable code? X means Natural Or Styrene-Butadiene Rubber.
What does R mean in a China (GB / JB/T / MT cable model codes) cable code? R means Flexible Cable.
What does H mean in a China (GB / JB/T / MT cable model codes) cable code? H means Communication Cable; or Cold Resistant; or Rubber Sheath; Chlorosulphonated Polyethylene (CSM) Sheath In Marine Cables.
Fire behaviour (EU CPR)
PE sheath (H).
Typically targeted, as declared by makers for this kind of construction in the examples this site checked (not the class of this cable):
FcaYMeKrvaslqwd, TKFFcaNA2XS(F)2Y, Waskönig+Walter
Listed as sources, alphabetically by maker. No maker pays to appear here.
A CPR class is declared by the maker in its Declaration of Performance and printed on the sheath (EN 50575 cl 7). This decoder does not assign one. What the CPR classes mean →
Sources: EN 13501-6 draft and FprEN 50575:2014 final draft (drafts, not the published texts); IEC 60332-3-24:2000+A1:2008; EN 13501-3 draft A2.
NXRH as the cable designer builds it, 4x16 0.6/1 kV
Overall diameter 26.4 mm, about 1,700 kg/km. Nominal values from the standard's tables for this size, computed, not a maker's data.
| Layer | Material | Thickness, mm | Over the layer, mm |
|---|---|---|---|
| Insulation | XLPE | 0.70 | 6.3 |
| Filler | PP | 15.2 | |
| Inner covering / bedding | Halogen-free (LSZH) | 1.0 | 17.2 |
| Sheath | Halogen-free (LSZH) | 1.2 | 19.6 |
| Wire armour | Steel | 40 × 1.60 | 22.8 |
| Sheath | Halogen-free (LSZH) | 1.8 | 26.4 |
NXRH on a drum
The smallest drum that passes every check, for 26.4 mm and about 1,700 kg/km as the cable designer builds it. Drums as their makers print them; lengths are estimates: whole layers wound nested (each turn in the groove of the layer below), wound diameter 1.05 × OD, 50 mm freeboard under the flange rim. Cable makers' own tables print less, as they count aligned layers.
| Length | Drum size (its makers) | Layers | Gross weight |
|---|---|---|---|
| 500 m | KTG 12 (1250 mm flange), wood KTG drums (Europe), Bayka, KTG | 9 of 10 | 994–1,015 kg |
| 1,000 m | KTG 16 (1600 mm flange), wood KTG drums (Europe), Bayka, KTG | 11 of 14 | 1,976–2,009 kg |
Barrel at least 15 × OD = 396 mm for a cable of this kind (Low voltage, multi-core): KTG table, the cable's datasheet wins. A load rating is the drum maker's own. A steel drum whose maker prints none is checked against the DIN 46391-4 guide load instead: 28 kN per m³ of gross winding volume.
Other lengths, drums and weights: the cable drum calculator
Load it on a truck: 1000 m on its drum in the loading planner
Laying, sizes and datasheet: NXRH
NXRH belongs to the family LV armoured cables: the lowest laying temperature, bending radius, pulling, depth, drum handling and the test after laying, every rule with its sources. Laying and handling guide: LV armoured cables
Its sizes are in AWG and kcmil, which are not the same as the nearest mm²: compare them by area and by resistance. AWG to mm²
Selling this cable? Open it in the designer and get a datasheet with your logo (Pro). Open the cable designer · See Pro
Work with NXRH
Who makes or stocks this cable?
Makers and stockists of this cable family appear here as sponsors for your region, each marked "Sponsored"; a listing never changes what this page says about the cable.