MPYC-S

MPYC-S is a JIS C 3410 shipboard cables cable designation: M = M: multicore, control and signal; P = P: EP rubber (EPR) insulation; -S = -S: individual shield, copper braid on each pair or core; Y = Y: PVC sheath; C = C: galvanised steel wire braid armour; MPYC-S = MPYC-S: shipboard multicore control and signal cable, 150/250 V, EPR insulation, individual copper braid shields, PVC sheath, galvanised steel wire braid. 150/250 V AC, 225/375 V DC; conductor 90 °C; 1 mm² cores, 2 to 44 cores (Table 24 Notes 3 and 4, p. 40). JIS C 3410:2010 Table 1 (p. 5) and Table 24 (p. 40); built on IEC 60092-351, -353, -354, -359 and -376 (Introduction, degree MOD).

1 coding system recognises this code

JIS C 3410 shipboard cables

SymbolMeaning
MM: multicore, control and signal
PP: EP rubber (EPR) insulation
-S-S: individual shield, copper braid on each pair or core
YY: PVC sheath
CC: galvanised steel wire braid armour
MPYC-SMPYC-S: shipboard multicore control and signal cable, 150/250 V, EPR insulation, individual copper braid shields, PVC sheath, galvanised steel wire braid. 150/250 V AC, 225/375 V DC; conductor 90 °C; 1 mm² cores, 2 to 44 cores (Table 24 Notes 3 and 4, p. 40). JIS C 3410:2010 Table 1 (p. 5) and Table 24 (p. 40); built on IEC 60092-351, -353, -354, -359 and -376 (Introduction, degree MOD)

What is MPYC-S cable?

MPYC-S: shipboard multicore control and signal cable, 150/250 V, EPR insulation, individual copper braid shields, PVC sheath, galvanised steel wire braid. Rating: 150/250 V AC, 225/375 V DC; conductor 90 °C; 1 mm² cores, 2 to 44 cores (Table 24 Notes 3 and 4, p. 40). Standard: JIS C 3410:2010 Table 1 (p. 5) and Table 24 (p. 40); built on IEC 60092-351, -353, -354, -359 and -376 (Introduction, degree MOD).

Read in JIS C 3410:2010 (JSA English translation), seen: standard. Table 24 (p. 40): 2 to 44 cores of 1 mm²; EPR insulation 0.6 mm; a copper braid shield of 0.12 mm wire on each core; PVC sheath 1.1 to 2.0 mm; steel braid wire 0.3 mm (0.4 mm at 44 cores); PVC protective covering 0.9 to 1.5 mm; routine test 1 500 V. Galvanised steel braid wire 0.3 or 0.4 mm (5.11.1, Table 7, p. 19), one over one under or two over two under, coverage at least 90 % (F at least 0.573, 6.16, p. 23); braid paint and protective covering white at 150/250 V and 0.6/1 kV, red at 3.6/6 and 6/10 kV, grey for fire resistant cables (6.16 c, 6.17, p. 24). Designation (cl. 10, p. 29): the symbol, a hyphen and the conductor size in mm², for multicore cables the number of cores, for telephone cables the number of pairs ("0.6/1 kV SPYC-120", "150/250 V MPYCY-12", "150/250 V TTYC-10"). FA- (flame retardant, bunched test 7.7: char at most 2.5 m) and FR- (fire resistant, mica tape under the insulation, 6.3, IEC 60331-21 or -31, 7.8) prefix the symbol.

Documents and pages the readings were taken from

  • JIS C 3410:2010, JSA English translation (first English edition 2011-09): Table 1 types and symbols pp. 2 to 8, Tables 2 and 3 letters pp. 8 to 9, construction Table 24 (p. 40)

JIS C 3410 shipboard cables: how to read the cable type names

Fire behaviour (EU CPR)

A CPR class is declared by the maker in its Declaration of Performance and printed on the sheath (EN 50575 cl 7). This decoder does not assign one. What the CPR classes mean →

Sources: EN 13501-6 draft and FprEN 50575:2014 final draft (drafts, not the published texts); IEC 60332-3-24:2000+A1:2008; EN 13501-3 draft A2.

Work with MPYC-S

Who makes or stocks this cable?

Makers and stockists of this cable family appear here as sponsors for your region, each marked "Sponsored"; a listing never changes what this page says about the cable.

Related cables

More JIS C 3410 shipboard cables designations

MPYC-S