JZ 500

JZ 500 is a HAR: HD 361 harmonised designation (CENELEC) cable designation: J = Per IEC (Greek National Prefix, e.g. J1VV-U); Z = Cross-Linked Polyolefin Compound, Low Smoke And Non-Corrosive Gases (Halogen-Free).

2 coding systems recognise this code

Standard, worked reading and related types

Worked reading of JZ 500:

  • JZ 500: J = Per IEC (Greek National Prefix, e.g. J1VV-U); Z = Cross-Linked Polyolefin Compound, Low Smoke And Non-Corrosive Gases (Halogen-Free)

HAR: HD 361 harmonised designation (CENELEC)

SymbolMeaning
JPer IEC (Greek National Prefix, e.g. J1VV-U)
ZCross-Linked Polyolefin Compound, Low Smoke And Non-Corrosive Gases (Halogen-Free)

How to read a HAR: HD 361 harmonised designation (CENELEC) cable code

NEN 3207 / KEMA (Netherlands)

SymbolMeaning
JGlass Fibre
ZLow Smoke Cross Linked Compound

How to read a NEN 3207 / KEMA (Netherlands) cable code

How to read a HAR: HD 361 harmonised designation (CENELEC) cable code

A HAR: HD 361 harmonised designation (CENELEC) designation (Europe (CENELEC)) is a row of letter groups, and each group stands for one part of the cable: conductor, insulation, screen, armour, sheath, or the standard it follows. The decoder knows 129 symbols for this system.

What does J mean in a HAR: HD 361 harmonised designation (CENELEC) cable code? J means Per IEC (Greek National Prefix, e.g. J1VV-U); or Glass Fibre Braiding.

What does Z mean in a HAR: HD 361 harmonised designation (CENELEC) cable code? Z means Cross-Linked Polyolefin Compound, Low Smoke And Non-Corrosive Gases (Halogen-Free).

Fire behaviour (EU CPR)

  • Halogen-free compound (Z). Under the CPR this shows in the additional classes: acidity a1 to a3 (EN 60754-2) and smoke s1 to s3 (EN 50399; s1a and s1b add the 3 m cube test EN 61034-2). The main class, Aca to Fca, depends on the whole construction.

    Typically targeted, as declared by makers for this kind of construction in the examples this site checked (not the class of this cable):

    Listed as sources, alphabetically by maker. No maker pays to appear here.

A CPR class is declared by the maker in its Declaration of Performance and printed on the sheath (EN 50575 cl 7). This decoder does not assign one. What the CPR classes mean →

Sources: EN 13501-6 draft and FprEN 50575:2014 final draft (drafts, not the published texts); IEC 60332-3-24:2000+A1:2008; EN 13501-3 draft A2.

Work with JZ 500

Who makes or stocks this cable?

Makers and stockists of this cable family appear here as sponsors for your region, each marked "Sponsored"; a listing never changes what this page says about the cable.

Related cables

More HAR: HD 361 harmonised designation (CENELEC) designations

JZ 500