GYTA

GYTA is a YD/T 908 (China, optical fibre) cable designation: GY = Outdoor cable (YD/T 908 class); - = No letter: metallic central strength member; T = Jelly-filled loose tubes stranded round the central member (as makers describe T); A = Aluminium-plastic bonded sheath (aluminium tape under the jacket); - = No jacket letter: polyethylene (PE) jacket; = Fibre count not given: drawn with 24.

1 coding system recognises this code

Standard, worked reading and related types

Worked reading of GYTA:

  • GYTA: GY = Outdoor cable (YD/T 908 class); - = No letter: metallic central strength member; T = Jelly-filled loose tubes stranded round the central member (as makers describe T); A = Aluminium-plastic bonded sheath (aluminium tape under the jacket); - = No jacket letter: polyethylene (PE) jacket; = Fibre count not given: drawn with 24

YD/T 908 (China, optical fibre)

SymbolMeaning
GYOutdoor cable (YD/T 908 class)
-No letter: metallic central strength member
TJelly-filled loose tubes stranded round the central member (as makers describe T)
AAluminium-plastic bonded sheath (aluminium tape under the jacket)
-No jacket letter: polyethylene (PE) jacket
Fibre count not given: drawn with 24

Fire behaviour (EU CPR)

  • PE sheath (-).

    Typically targeted, as declared by makers for this kind of construction in the examples this site checked (not the class of this cable):

    Listed as sources, alphabetically by maker. No maker pays to appear here.

A CPR class is declared by the maker in its Declaration of Performance and printed on the sheath (EN 50575 cl 7). This decoder does not assign one. What the CPR classes mean →

Sources: EN 13501-6 draft and FprEN 50575:2014 final draft (drafts, not the published texts); IEC 60332-3-24:2000+A1:2008; EN 13501-3 draft A2.

GYTA as the cable designer builds it, GYTA 24B1.3

Overall diameter 8.7 mm, 75 kg/km. An optical fibre cable has no conductor and no voltage: every size is its maker's, the layers no maker prints drawn at a typical value.

LayerMaterialThickness, mmOver the layer, mm
Central strength memberSteel1.4
Filler rodPE1.7
Loose tube (gel-filled, fibres inside)PBT0.261.7
Swelling tape (water block)Swelling0.155.1
Laminate (radial water block)Aluminium0.205.5
SheathPE1.68.7

GYTA on a drum

The smallest drum that passes every check, for 8.7 mm and about 75 kg/km as the cable designer builds it. Drums as their makers print them; lengths are estimates: whole layers wound nested (each turn in the groove of the layer below), wound diameter 1.05 × OD, 50 mm freeboard under the flange rim. Cable makers' own tables print less, as they count aligned layers.

LengthDrum size (its makers)LayersGross weight
500 mKTG 6 (600 mm flange), plywood KTG drums (Europe), Bayka11 of 1545 kg
1,000 mKTG 8 (800 mm flange), wood KTG drums (Europe), Bayka, KTG15 of 18106–110 kg

Barrel at least 20 × OD = 174 mm for a cable of this kind (Telecom, data and control cable): KTG table, the cable's datasheet wins. A load rating is the drum maker's own. A steel drum whose maker prints none is checked against the DIN 46391-4 guide load instead: 28 kN per m³ of gross winding volume.

Other lengths, drums and weights: the cable drum calculator

Load it on a truck: 1000 m on its drum in the loading planner

Laying, sizes and datasheet: GYTA

GYTA belongs to the family Fibre optic cables: the lowest laying temperature, bending radius, pulling, depth, drum handling and the test after laying, every rule with its sources. Laying and handling guide: Fibre optic cables

Selling this cable? Open it in the designer and get a datasheet with your logo (Pro). Open the cable designer · See Pro

Work with GYTA

Who makes or stocks this cable?

Makers and stockists of this cable family appear here as sponsors for your region, each marked "Sponsored"; a listing never changes what this page says about the cable.

GYTA