FR-CV

FR-CV is a TCVN type names (Vietnam) cable designation: CV = CV: copper (C) conductor with PVC (V) insulation, single core, no sheath (Vietnamese makers' name); CV = CV (Vietnam): single-core stranded (class 2) copper wire, PVC insulation, no sheath. 450/750 V (TCVN 6610-3), 0.6/1 kV with V-75 PVC (AS/NZS 5000.1), 600 V (JIS C 3307), as Cadivi prints them. TCVN 6610-3:2000 (60227 IEC 01, 450/750 V); AS/NZS 5000.1 (0.6/1 kV); JIS C 3307 (600 V) (Cadivi).

4 coding systems recognise this code

TCVN type names (Vietnam)

SymbolMeaning
CVCV: copper (C) conductor with PVC (V) insulation, single core, no sheath (Vietnamese makers' name)
CVCV (Vietnam): single-core stranded (class 2) copper wire, PVC insulation, no sheath. 450/750 V (TCVN 6610-3), 0.6/1 kV with V-75 PVC (AS/NZS 5000.1), 600 V (JIS C 3307), as Cadivi prints them. TCVN 6610-3:2000 (60227 IEC 01, 450/750 V); AS/NZS 5000.1 (0.6/1 kV); JIS C 3307 (600 V) (Cadivi)

JIS type names (Japan)

SymbolMeaning
CC: cross-linked polyethylene (XLPE) insulation
VV: PVC (vinyl) sheath
CVCV: 600 V XLPE insulated, PVC sheathed power cable, copper conductors. 600 V, 90 C (SWCC/Furukawa SFCC p.12; Sumitomo HST-SS30-0500). JIS C 3605 (600 V); JCS 4516 (3300 V); JIS C 3606 (6600 V)

CEI-UNEL 35011 (Italy)

SymbolMeaning
FFine-Wired In Flexible Cables-Class 5
RPVC Compound (TI1/TI2 Quality, 70 °C)
CConcentric Copper Conductor
VImpregnated Glass Tape

How to read a CEI-UNEL 35011 (Italy) cable code

Norwegian type designation (NEK 606 offshore and Norwegian land cables)

SymbolMeaning
FPE Or PP + Filling Compound
REthylene Propylene Rubber (EPR)
CGalvanized Steel Wire Braid
VOther Halogen-Free Thermoset Materials (Draka BFOV: oil-resistant HNBR; Nexans Norway key: EVA)

How to read a Norwegian type designation (NEK 606 offshore and Norwegian land cables) cable code

Fire behaviour (EU CPR)

A CPR class is declared by the maker in its Declaration of Performance and printed on the sheath (EN 50575 cl 7). This decoder does not assign one. What the CPR classes mean →

Sources: EN 13501-6 draft and FprEN 50575:2014 final draft (drafts, not the published texts); IEC 60332-3-24:2000+A1:2008; EN 13501-3 draft A2.

FR-CV as the cable designer builds it, 1x1.5 450/750 V

Overall diameter 3.0 mm, about 20 kg/km. Nominal values from the standard's tables for this size, computed, not a maker's data.

LayerMaterialThickness, mmOver the layer, mm
InsulationPVC0.703.0

FR-CV on a drum

The smallest drum that passes every check, for 3 mm and about 20 kg/km as the cable designer builds it. Drums as their makers print them; lengths are estimates within a few per cent of the cable makers' own tables: whole layers, wound diameter 1.05 × OD, 50 mm freeboard under the flange rim.

LengthDrum size (its makers)LayersGross weight
500 mKTG 3 (390 mm flange), plastic KTG drums (Europe), KTG8 of 2612 kg
1,000 mKTG 3 (390 mm flange), plastic KTG drums (Europe), KTG15 of 2622 kg

Barrel at least 20 × OD = 59 mm for a cable of this kind (Low voltage, single core): KTG table, the cable's datasheet wins. A load rating is the drum maker's own.

Other lengths, drums and weights: the cable drum calculator

Load it on a truck: 1000 m on its drum in the loading planner