FKKJ
FKKJ is a SS 424 17 01 (Sweden) cable designation: F = Copper Conductor, Few-Stranded (Class 2); K = Polyvinyl Chloride (PVC); K = Polyvinyl Chloride (PVC); J = Underground Use.
1 coding system recognises this code
Standard, worked reading and related types
Standards behind these values: IEC 60502-1:2004 (edition 2.0): Power cables with extruded insulation and their accessories for rated voltages from 1 kV (Um = 1,2 kV) up to 30 kV (Um = 36 kV) - Part 1: Cables for rated voltages of 1 kV (Um = 1,2 kV) and 3 kV (Um = 3,6 kV); IEC 60228:2023 (edition 4.0): Conductors of insulated cables. How the values are sourced
Worked reading of FKKJ 3x95 0.6/1 kV:
FKKJ: F = Copper Conductor, Few-Stranded (Class 2); K = Polyvinyl Chloride (PVC); K = Polyvinyl Chloride (PVC); J = Underground Use3x95 0.6/1 kV: 3 cores, each copper 95 mm²; rated voltage 0.6/1 kV
SS 424 17 01 (Sweden)
| Symbol | Meaning |
|---|---|
F | Copper Conductor, Few-Stranded (Class 2) |
K | Polyvinyl Chloride (PVC) |
K | Polyvinyl Chloride (PVC) |
J | Underground Use |
How to read a SS 424 17 01 (Sweden) cable code
A SS 424 17 01 (Sweden) designation (Sweden) is a row of letter groups, and each group stands for one part of the cable: conductor, insulation, screen, armour, sheath, or the standard it follows. The decoder knows 90 symbols for this system.
What does F mean in a SS 424 17 01 (Sweden) cable code? F means Copper Conductor, Few-Stranded (Class 2); or Copper Screen As Braid; or Copper or Steel Braid; or Firmly Attached Outer Conductive Layer, Medium Voltage Cable.
What does K mean in a SS 424 17 01 (Sweden) cable code? K means Polyvinyl Chloride (PVC).
What does J mean in a SS 424 17 01 (Sweden) cable code? J means Steel Wire Conductor; or Steel Tape Armour; or Underground Use; or For Laying In Ground.
Fire behaviour (EU CPR)
PVC sheath (K).
Typically targeted, as declared by makers for this kind of construction in the examples this site checked (not the class of this cable):
EcaN1XV-R, Ahlsell (seller)Cca-s3,d1,a3FG16OR16, Nexans (La Triveneta Cavi)EcaU1000 R2V, Nexans (La Triveneta Cavi)EcaN2XSY, Waskönig+Walter (10 kV datasheet)
Listed as sources, alphabetically by maker. No maker pays to appear here.
A CPR class is declared by the maker in its Declaration of Performance and printed on the sheath (EN 50575 cl 7). This decoder does not assign one. What the CPR classes mean →
Sources: EN 13501-6 draft and FprEN 50575:2014 final draft (drafts, not the published texts); IEC 60332-3-24:2000+A1:2008; EN 13501-3 draft A2.
FKKJ: equivalents in other countries
Shown for 3x95 0.6/1 kV. Each country's rules are applied to this build, keeping the conductor, section, cores, voltage, screen, armour and sheath.
| Country | Standard | Name in that country | Verdict | Differences |
|---|---|---|---|---|
| Germany | HD 603 3-G (DIN VDE 0276-603) | NYY 3x95 RM 0,6/1 kV | Equivalent | every value the same |
| India | IS 1554 (Part 1) | YY 3x95 1100 V (the code letters of IS 1554 (Part 1):1988 cl. 17.3) | Close | rated 0.635/1.1 kV (same Um 1.2 kV); routine voltage test 3 kV a.c., 5 min (this cable 3.5 kV; IS 1554 (Part 1) cl. 16.2, IS 7098 (Part 1) cl. 17.2.1, IEC 60502-1 Table 11); Inner covering / bedding 1.2 → 0.4 mm; Sheath 2.1 → 2.2 mm; this cable as built misses 1 of its rules |
Nominal values computed by each standard's rules, not manufacturer data. This is not a statement that two cables are interchangeable: the buyer's specification and the maker's type test decide.
FKKJ as the cable designer builds it, 3x95 0.6/1 kV
Overall diameter 38.3 mm, about 3,580 kg/km. Nominal values from the standard's tables for this size, computed, not a maker's data.
| Layer | Material | Thickness, mm | Over the layer, mm |
|---|---|---|---|
| Insulation | PVC | 1.6 | 14.7 |
| Filler | PP | 31.7 | |
| Inner covering / bedding | PVC | 1.2 | 34.1 |
| Sheath | PVC | 2.1 | 38.3 |
FKKJ on a drum
The smallest drum that passes every check, for 38.3 mm and about 3,580 kg/km as the cable designer builds it. Drums as their makers print them; lengths are estimates: whole layers wound nested (each turn in the groove of the layer below), wound diameter 1.05 × OD, 50 mm freeboard under the flange rim. Cable makers' own tables print less, as they count aligned layers.
| Length | Drum size (its makers) | Layers | Gross weight |
|---|---|---|---|
| 500 m | KTG 16 (1600 mm flange), wood KTG drums (Europe), Bayka, KTG | 8 of 9 | 2,066–2,099 kg |
| 1,000 m | KTG 20 (2000 mm flange), wood KTG drums (Europe), Bayka, KTG | 9 of 9 | 4,059–4,180 kg |
Barrel at least 15 × OD = 574 mm for a cable of this kind (Low voltage, multi-core): KTG table, the cable's datasheet wins. A load rating is the drum maker's own. A steel drum whose maker prints none is checked against the DIN 46391-4 guide load instead: 28 kN per m³ of gross winding volume.
Other lengths, drums and weights: the cable drum calculator
Load it on a truck: 1000 m on its drum in the loading planner
Laying, sizes and datasheet: FKKJ
FKKJ belongs to the family LV PVC power cables: the lowest laying temperature, bending radius, pulling, depth, drum handling and the test after laying, every rule with its sources. Laying and handling guide: LV PVC power cables