EXeLW

EXeLW is a China (GB / JB/T / MT cable model codes) cable designation: E = Low Smoke Zero Halogen Compound; X = Natural Or Styrene-Butadiene Rubber; E = Low Smoke Zero Halogen Compound; LW = Aluminium Sheath, Pressed Or Welded, Corrugated.

2 coding systems recognise this code

Standard, worked reading and related types

Worked reading of EXeLW:

  • EXeLW: E = Low Smoke Zero Halogen Compound; X = Natural Or Styrene-Butadiene Rubber; E = Low Smoke Zero Halogen Compound; LW = Aluminium Sheath, Pressed Or Welded, Corrugated

China (GB / JB/T / MT cable model codes)

SymbolMeaning
ELow Smoke Zero Halogen Compound
XNatural Or Styrene-Butadiene Rubber
ELow Smoke Zero Halogen Compound
LWAluminium Sheath, Pressed Or Welded, Corrugated

How to read a China (GB / JB/T / MT cable model codes) cable code

NBN (Belgian national cable names, ...B types)

SymbolMeaning
EEnergy Cable
XCross-Linked Polyethylene (XLPE)
eSwelling Tape, Longitudinally Watertight (After C: Al/PE Water Barrier, Transversely Watertight)
LLead Sheath
WPolyethylene (PE)

How to read a NBN (Belgian national cable names, ...B types) cable code

How to read a China (GB / JB/T / MT cable model codes) cable code

A China (GB / JB/T / MT cable model codes) designation (China) is a row of letter groups, and each group stands for one part of the cable: conductor, insulation, screen, armour, sheath, or the standard it follows. The decoder knows 137 symbols for this system.

What does E mean in a China (GB / JB/T / MT cable model codes) cable code? E means Low Smoke Zero Halogen Compound.

What does X mean in a China (GB / JB/T / MT cable model codes) cable code? X means Natural Or Styrene-Butadiene Rubber.

What does LW mean in a China (GB / JB/T / MT cable model codes) cable code? LW means Aluminium Sheath, Pressed Or Welded, Corrugated.

Fire behaviour (EU CPR)

  • Halogen-free compound (E). Under the CPR this shows in the additional classes: acidity a1 to a3 (EN 60754-2) and smoke s1 to s3 (EN 50399; s1a and s1b add the 3 m cube test EN 61034-2). The main class, Aca to Fca, depends on the whole construction.

    Typically targeted, as declared by makers for this kind of construction in the examples this site checked (not the class of this cable):

    Listed as sources, alphabetically by maker. No maker pays to appear here.

A CPR class is declared by the maker in its Declaration of Performance and printed on the sheath (EN 50575 cl 7). This decoder does not assign one. What the CPR classes mean →

Sources: EN 13501-6 draft and FprEN 50575:2014 final draft (drafts, not the published texts); IEC 60332-3-24:2000+A1:2008; EN 13501-3 draft A2.

Work with EXeLW

Who makes or stocks this cable?

Makers and stockists of this cable family appear here as sponsors for your region, each marked "Sponsored"; a listing never changes what this page says about the cable.

Related cables

More China (GB / JB/T / MT cable model codes) designations

EXeLW