DPYSLA is a JIS C 3410 shipboard cables cable designation: D = D: two cores (double), power and lighting; P = P: EP rubber (EPR) insulation; SLA = SLA: common shield, aluminium / polyester tape over the laid-up cores; Y = Y: PVC sheath; DPYSLA = DPYSLA: shipboard two-core power and lighting cable, 0.6/1 kV, EPR insulation, PVC sheath, common aluminium / polyester tape shield. 0.6/1 kV; conductor 90 C (TMC p.6, p.10, p.12). TMC catalogue name (TMC cites JIS C 3410(2010)); not a type of JIS C 3410:2010 Table 1.

1 coding system recognises this code

JIS C 3410 shipboard cables

SymbolMeaning
DD: two cores (double), power and lighting
PP: EP rubber (EPR) insulation
SLASLA: common shield, aluminium / polyester tape over the laid-up cores
YY: PVC sheath
DPYSLADPYSLA: shipboard two-core power and lighting cable, 0.6/1 kV, EPR insulation, PVC sheath, common aluminium / polyester tape shield. 0.6/1 kV; conductor 90 C (TMC p.6, p.10, p.12). TMC catalogue name (TMC cites JIS C 3410(2010)); not a type of JIS C 3410:2010 Table 1

What is DPYSLA cable?

DPYSLA: shipboard two-core power and lighting cable, 0.6/1 kV, EPR insulation, PVC sheath, common aluminium / polyester tape shield. Rating: 0.6/1 kV; conductor 90 C (TMC p.6, p.10, p.12). Standard: TMC catalogue name (TMC cites JIS C 3410(2010)); not a type of JIS C 3410:2010 Table 1.

Not in JIS C 3410:2010 Table 1 (pp. 2 to 8): TMC's own variant, so its values stay at seen level manufacturer. Name printed in the TMC index p.4 ('(FA-) DPYSLA'). TMC 'Marine & Shipboard Cable, JIS C 3410(2010) / IEC 60092-350, 353, 354, 376' (manufacturer), p.4 'Code Designation': FA- flame retardant, FR- fire resistance, FR-FA-, S / D / T / F single to four cores for power and lighting, M multi core for control and signal, TT telephone and instrumentation; material letters, column alignment checked on a rendered image of p.4: insulation P EP rubber, Y PVC, C XLPE; sheath Y PVC; armouring C steel wire, CB copper alloy wire; protective covering Y PVC; others SLA common shield (AL/PS tape), -SLA individual shield (AL/PS tape), -S individual shield (copper braid), E earth wire, (C) cold type (not read here). Notes: telephone cables omit the insulation letter; CB for a copper alloy braid (0.6/1KV SPYCB, SPYCBY); E suffixed for an earth wire (0.6/1kV TPYE). Pp.6, 10, 12: stranded tinned annealed copper, EPR and PVC to JIS C 3410(2010), braid coverage min. 90 %, conductor 90 C, IEC 60332-1 (FA-: IEC 60332-3 Cat. A).

Documents and pages the readings were taken from

JIS C 3410 shipboard cables: how to read the cable type names

Fire behaviour (EU CPR)

A CPR class is declared by the maker in its Declaration of Performance and printed on the sheath (EN 50575 cl 7). This decoder does not assign one. What the CPR classes mean →

Sources: EN 13501-6 draft and FprEN 50575:2014 final draft (drafts, not the published texts); IEC 60332-3-24:2000+A1:2008; EN 13501-3 draft A2.