DPLC
DPLC is a JIS C 3410 shipboard cables cable designation: D = D: two cores (double), power and lighting; P = P: EP rubber (EPR) insulation; L = L: lead alloy sheath; C = C: galvanised steel wire braid armour; DPLC = DPLC: shipboard two-core power and lighting cable, 0.6/1 kV, EPR insulation, lead alloy sheath, galvanised steel wire braid. 0.6/1 kV AC, 0.9/1.5 kV DC; conductor 90 °C; 1.5, 2.5 and 4 mm² (Table 19 Notes 3 and 4, p. 35). JIS C 3410:2010 Table 1 (p. 4) and Table 19 (p. 35); built on IEC 60092-351, -353, -354, -359 and -376 (Introduction, degree MOD).
1 coding system recognises this code
JIS C 3410 shipboard cables
| Symbol | Meaning |
|---|---|
D | D: two cores (double), power and lighting |
P | P: EP rubber (EPR) insulation |
L | L: lead alloy sheath |
C | C: galvanised steel wire braid armour |
DPLC | DPLC: shipboard two-core power and lighting cable, 0.6/1 kV, EPR insulation, lead alloy sheath, galvanised steel wire braid. 0.6/1 kV AC, 0.9/1.5 kV DC; conductor 90 °C; 1.5, 2.5 and 4 mm² (Table 19 Notes 3 and 4, p. 35). JIS C 3410:2010 Table 1 (p. 4) and Table 19 (p. 35); built on IEC 60092-351, -353, -354, -359 and -376 (Introduction, degree MOD) |
What is DPLC cable?
DPLC: shipboard two-core power and lighting cable, 0.6/1 kV, EPR insulation, lead alloy sheath, galvanised steel wire braid. Rating: 0.6/1 kV AC, 0.9/1.5 kV DC; conductor 90 °C; 1.5, 2.5 and 4 mm² (Table 19 Notes 3 and 4, p. 35). Standard: JIS C 3410:2010 Table 1 (p. 4) and Table 19 (p. 35); built on IEC 60092-351, -353, -354, -359 and -376 (Introduction, degree MOD).
Read in JIS C 3410:2010 (JSA English translation), seen: standard. Table 19 (p. 35): two or three cores of 1.5, 2.5 or 4 mm²; EPR insulation 1.0 mm; lead alloy sheath 1.0 mm (5.10.1) with bituminous compound and tape bedding (6.15); steel braid wire 0.3 mm; PVC protective covering 0.9 to 1.0 mm; routine test 3 500 V. Galvanised steel braid wire 0.3 or 0.4 mm (5.11.1, Table 7, p. 19), one over one under or two over two under, coverage at least 90 % (F at least 0.573, 6.16, p. 23); braid paint and protective covering white at 150/250 V and 0.6/1 kV, red at 3.6/6 and 6/10 kV, grey for fire resistant cables (6.16 c, 6.17, p. 24). Designation (cl. 10, p. 29): the symbol, a hyphen and the conductor size in mm², for multicore cables the number of cores, for telephone cables the number of pairs ("0.6/1 kV SPYC-120", "150/250 V MPYCY-12", "150/250 V TTYC-10"). FA- (flame retardant, bunched test 7.7: char at most 2.5 m) and FR- (fire resistant, mica tape under the insulation, 6.3, IEC 60331-21 or -31, 7.8) prefix the symbol.
Documents and pages the readings were taken from
- JIS C 3410:2010, JSA English translation (first English edition 2011-09): Table 1 types and symbols pp. 2 to 8, Tables 2 and 3 letters pp. 8 to 9, construction Table 19 (p. 35)
JIS C 3410 shipboard cables: how to read the cable type names
Work with DPLC
Who makes or stocks this cable?
Makers and stockists of this cable family appear here as sponsors for your region, each marked "Sponsored"; a listing never changes what this page says about the cable.