AXQJ

AXQJ is a SS 424 17 01 (Sweden) cable designation: A = Aluminium Conductor; X = Cross-Linked Polyethylene (XLPE, PEX); Q = Low Smoke, Zero Halogen Thermoplastic Polyolefin; J = Underground Use.

1 coding system recognises this code

Standard, worked reading and related types

Standards behind these values: IEC 60502-1:2004 (edition 2.0): Power cables with extruded insulation and their accessories for rated voltages from 1 kV (Um = 1,2 kV) up to 30 kV (Um = 36 kV) - Part 1: Cables for rated voltages of 1 kV (Um = 1,2 kV) and 3 kV (Um = 3,6 kV); IEC 60228:2023 (edition 4.0): Conductors of insulated cables. How the values are sourced

Worked reading of AXQJ 3x95 0.6/1 kV:

  • AXQJ: A = Aluminium Conductor; X = Cross-Linked Polyethylene (XLPE, PEX); Q = Low Smoke, Zero Halogen Thermoplastic Polyolefin; J = Underground Use
  • 3x95 0.6/1 kV: 3 cores, each aluminium 95 mm²; rated voltage 0.6/1 kV

SS 424 17 01 (Sweden)

SymbolMeaning
AAluminium Conductor
XCross-Linked Polyethylene (XLPE, PEX)
QLow Smoke, Zero Halogen Thermoplastic Polyolefin
JUnderground Use

How to read a SS 424 17 01 (Sweden) cable code

How to read a SS 424 17 01 (Sweden) cable code

A SS 424 17 01 (Sweden) designation (Sweden) is a row of letter groups, and each group stands for one part of the cable: conductor, insulation, screen, armour, sheath, or the standard it follows. The decoder knows 90 symbols for this system.

What does A mean in a SS 424 17 01 (Sweden) cable code? A means Aluminium Conductor; or Screen Of Aluminium Foil And/Or Aluminium Wire.

What does X mean in a SS 424 17 01 (Sweden) cable code? X means Cross-Linked Polyethylene (XLPE, PEX); or Polyvinyl Chloride (PVC), Oval Section; or Without Protective Conductor (Size Field).

What does Q mean in a SS 424 17 01 (Sweden) cable code? Q means Low Smoke, Zero Halogen Thermoplastic Polyolefin.

What does J mean in a SS 424 17 01 (Sweden) cable code? J means Steel Wire Conductor; or Steel Tape Armour; or Underground Use; or For Laying In Ground.

Fire behaviour (EU CPR)

  • Halogen-free compound (Q). Under the CPR this shows in the additional classes: acidity a1 to a3 (EN 60754-2) and smoke s1 to s3 (EN 50399; s1a and s1b add the 3 m cube test EN 61034-2). The main class, Aca to Fca, depends on the whole construction.

    Typically targeted, as declared by makers for this kind of construction in the examples this site checked (not the class of this cable):

    Listed as sources, alphabetically by maker. No maker pays to appear here.

A CPR class is declared by the maker in its Declaration of Performance and printed on the sheath (EN 50575 cl 7). This decoder does not assign one. What the CPR classes mean →

Sources: EN 13501-6 draft and FprEN 50575:2014 final draft (drafts, not the published texts); IEC 60332-3-24:2000+A1:2008; EN 13501-3 draft A2.

AXQJ: equivalents in other countries

Shown for 3x95 0.6/1 kV. Each country's rules are applied to this build, keeping the conductor, section, cores, voltage, screen, armour and sheath.

CountryStandardName in that countryVerdictDifferences
GermanyHD 603 5-G (DIN VDE 0276-603)NA2XH 3x95 RM 0,6/1 kVEquivalentevery value the same
IndiaIS 7098 (Part 1)A2XZ 3x95 1100 V (the code letters of IS 7098 (Part 1):2025 cl. 18.3)Closerated 0.635/1.1 kV (same Um 1.2 kV); routine voltage test 3 kV a.c., 5 min (this cable 3.5 kV; IS 1554 (Part 1) cl. 16.2, IS 7098 (Part 1) cl. 17.2.1, IEC 60502-1 Table 11); Inner covering / bedding 1.2 → 0.4 mm; Sheath 2 → 2.2 mm; this cable as built misses 1 of its rules
South AfricaSANS 1507-4no letters for this buildCloseInner covering / bedding material LSZH → PVC; Inner covering / bedding 1.2 → 1.4 mm; Sheath material LSZH → PVC; Sheath 2 → 2.2 mm

No equivalent in: BS 5467 (armoured cables only, asks another sheath compound); BS 6724 (armoured cables only); BS 7846 (not in its cable tables, armoured cables only).

Nominal values computed by each standard's rules, not manufacturer data. This is not a statement that two cables are interchangeable: the buyer's specification and the maker's type test decide.

AXQJ as the cable designer builds it, 3x95 0.6/1 kV

Overall diameter 35.9 mm, about 1,530 kg/km. Nominal values from the standard's tables for this size, computed, not a maker's data.

LayerMaterialThickness, mmOver the layer, mm
InsulationXLPE1.113.7
FillerPP29.5
Inner covering / beddingHalogen-free (LSZH)1.231.9
SheathHalogen-free (LSZH)2.035.9

AXQJ on a drum

The smallest drum that passes every check, for 35.9 mm and about 1,530 kg/km as the cable designer builds it. Drums as their makers print them; lengths are estimates: whole layers wound nested (each turn in the groove of the layer below), wound diameter 1.05 × OD, 50 mm freeboard under the flange rim. Cable makers' own tables print less, as they count aligned layers.

LengthDrum size (its makers)LayersGross weight
500 mKTG 16 (1600 mm flange), wood KTG drums (Europe), Bayka, KTG7 of 101,041–1,074 kg
1,000 mKTG 20 (2000 mm flange), wood KTG drums (Europe), Bayka, KTG8 of 92,009–2,130 kg

Barrel at least 15 × OD = 539 mm for a cable of this kind (Low voltage, multi-core): KTG table, the cable's datasheet wins. A load rating is the drum maker's own. A steel drum whose maker prints none is checked against the DIN 46391-4 guide load instead: 28 kN per m³ of gross winding volume.

Other lengths, drums and weights: the cable drum calculator

Load it on a truck: 1000 m on its drum in the loading planner

Laying, sizes and datasheet: AXQJ

Current rating and voltage drop: One circuit, C: cable on a wall, 30 °C air: about 211 A. At that current over 100 m, three-phase 400 V, cos φ 0.9: a voltage drop of about 3.7 %. Sources: IEC 60364-5-52:2009, Table B.52.5, p. 44; IEC 60228:2023 Table 4, p. 13; IEC 60228:2023 Annex B, p. 18; IEC 60364-5-52:2009 (ed. 3.0) Annex G (informative), pp. 74 to 75 (read in the standard text) Cable size calculator: smallest section for a load, every factor shown · Voltage drop calculator: IEC 60364-5-52 method and limits

AXQJ belongs to the family LV XLPE power cables: the lowest laying temperature, bending radius, pulling, depth, drum handling and the test after laying, every rule with its sources. Laying and handling guide: LV XLPE power cables

Selling this cable? Open it in the designer and get a datasheet with your logo (Pro). Open the cable designer · See Pro

Work with AXQJ

Who makes or stocks this cable?

Makers and stockists of this cable family appear here as sponsors for your region, each marked "Sponsored"; a listing never changes what this page says about the cable.

Related cables

More SS 424 17 01 (Sweden) designations

AXQJ