ATM
ATM is a VDE telecom, signal and fibre cables (DIN VDE 0815, 0816, 0813, 0888) cable designation: AT = Breakout (Divisible) Outdoor Cable; M = Lead Sheath.
6 coding systems recognise this code
Standard, worked reading and related types
Worked reading of ATM:
ATM: AT = Breakout (Divisible) Outdoor Cable; M = Lead Sheath
VDE telecom, signal and fibre cables (DIN VDE 0815, 0816, 0813, 0888)
| Symbol | Meaning |
|---|---|
AT | Breakout (Divisible) Outdoor Cable |
M | Lead Sheath |
How to read a VDE telecom, signal and fibre cables (DIN VDE 0815, 0816, 0813, 0888) cable code
UTE (France, NF C 30-202 traditional system)
| Symbol | Meaning |
|---|---|
A | Aluminium Conductor |
T | Textile Braiding Over Twisted Cores |
M | Flat Type |
How to read a UTE (France, NF C 30-202 traditional system) cable code
China (GB / JB/T / MT cable model codes)
| Symbol | Meaning |
|---|---|
A | Twin Cable |
T | Copper Conductor |
M | Watertight |
How to read a China (GB / JB/T / MT cable model codes) cable code
CEI-UNEL 35011 (Italy)
| Symbol | Meaning |
|---|---|
A | Aluminium Conductor |
T | One Or More Mica Glass Tapes, Or A Closed Glass Braid |
M | Mineral Insulation |
India (IS 1554 / IS 7098 cable code)
| Symbol | Meaning |
|---|---|
A | Aluminium Conductor |
T | Double Steel Tape Armour |
M | Shipboard or Marine Cable |
How to read a India (IS 1554 / IS 7098 cable code) cable code
SS 424 17 01 (Sweden)
| Symbol | Meaning |
|---|---|
A | Aluminium Conductor |
T | Fluoroplastic |
M | Copper Conductor, Few-Stranded |
How to read a VDE telecom, signal and fibre cables (DIN VDE 0815, 0816, 0813, 0888) cable code
A VDE telecom, signal and fibre cables (DIN VDE 0815, 0816, 0813, 0888) designation (Germany) is a row of letter groups, and each group stands for one part of the cable: conductor, insulation, screen, armour, sheath, or the standard it follows. The decoder knows 125 symbols for this system.
What does AT mean in a VDE telecom, signal and fibre cables (DIN VDE 0815, 0816, 0813, 0888) cable code? AT means Breakout (Divisible) Outdoor Cable.
What does M mean in a VDE telecom, signal and fibre cables (DIN VDE 0815, 0816, 0813, 0888) cable code? M means Lead Sheath.
Laying, sizes and datasheet: ATM
Terms on this page: breakout (crutch)
Work with ATM
Who makes or stocks this cable?
Makers and stockists of this cable family appear here as sponsors for your region, each marked "Sponsored"; a listing never changes what this page says about the cable.
Related cables
More VDE telecom, signal and fibre cables (DIN VDE 0815, 0816, 0813, 0888) designations