APBY
APBY is a VDE telecom, signal and fibre cables (DIN VDE 0815, 0816, 0813, 0888) cable designation: A = Outdoor Cable; P = Paper Insulation; B = Helical Galvanized Steel Tape; Y = Polyvinyl Chloride (PVC).
3 coding systems recognise this code
Standard, worked reading and related types
Worked reading of APBY:
APBY: A = Outdoor Cable; P = Paper Insulation; B = Helical Galvanized Steel Tape; Y = Polyvinyl Chloride (PVC)
VDE telecom, signal and fibre cables (DIN VDE 0815, 0816, 0813, 0888)
| Symbol | Meaning |
|---|---|
A | Outdoor Cable |
P | Paper Insulation |
B | Helical Galvanized Steel Tape |
Y | Polyvinyl Chloride (PVC) |
How to read a VDE telecom, signal and fibre cables (DIN VDE 0815, 0816, 0813, 0888) cable code
China (GB / JB/T / MT cable model codes)
| Symbol | Meaning |
|---|---|
A | Twin Cable |
P | Copper Screen As Braid |
B | Polypropylene (PP) |
Y | Polyethylene (PE) Or Polyolefin |
How to read a China (GB / JB/T / MT cable model codes) cable code
India (IS 1554 / IS 7098 cable code)
| Symbol | Meaning |
|---|---|
A | Aluminium Conductor |
P | Paper Insulation |
B | Braiding, Compounding Or Varnishing |
Y | Polyvinyl Chloride (PVC) |
How to read a India (IS 1554 / IS 7098 cable code) cable code
How to read a VDE telecom, signal and fibre cables (DIN VDE 0815, 0816, 0813, 0888) cable code
A VDE telecom, signal and fibre cables (DIN VDE 0815, 0816, 0813, 0888) designation (Germany) is a row of letter groups, and each group stands for one part of the cable: conductor, insulation, screen, armour, sheath, or the standard it follows. The decoder knows 125 symbols for this system.
What does A mean in a VDE telecom, signal and fibre cables (DIN VDE 0815, 0816, 0813, 0888) cable code? A means Outdoor Cable.
What does P mean in a VDE telecom, signal and fibre cables (DIN VDE 0815, 0816, 0813, 0888) cable code? P means Paper Insulation; or Polymer Optical Fibre (Fibre Type).
What does B mean in a VDE telecom, signal and fibre cables (DIN VDE 0815, 0816, 0813, 0888) cable code? B means With Lightning Protection; or Bundled Cores, Unfilled; or Helical Galvanized Steel Tape; or Armoured.
What does Y mean in a VDE telecom, signal and fibre cables (DIN VDE 0815, 0816, 0813, 0888) cable code? Y means Polyvinyl Chloride (PVC).
Fire behaviour (EU CPR)
PVC sheath (Y).
Typically targeted, as declared by makers for this kind of construction in the examples this site checked (not the class of this cable):
EcaN1XV-R, Ahlsell (seller)Cca-s3,d1,a3FG16OR16, Nexans (La Triveneta Cavi)EcaU1000 R2V, Nexans (La Triveneta Cavi)EcaN2XSY, Waskönig+Walter (10 kV datasheet)
Listed as sources, alphabetically by maker. No maker pays to appear here.
A CPR class is declared by the maker in its Declaration of Performance and printed on the sheath (EN 50575 cl 7). This decoder does not assign one. What the CPR classes mean →
Sources: EN 13501-6 draft and FprEN 50575:2014 final draft (drafts, not the published texts); IEC 60332-3-24:2000+A1:2008; EN 13501-3 draft A2.
Work with APBY