APBY

APBY is a VDE telecom, signal and fibre cables (DIN VDE 0815, 0816, 0813, 0888) cable designation: A = Outdoor Cable; P = Paper Insulation; B = Helical Galvanized Steel Tape; Y = Polyvinyl Chloride (PVC).

3 coding systems recognise this code

Standard, worked reading and related types

Worked reading of APBY:

  • APBY: A = Outdoor Cable; P = Paper Insulation; B = Helical Galvanized Steel Tape; Y = Polyvinyl Chloride (PVC)

VDE telecom, signal and fibre cables (DIN VDE 0815, 0816, 0813, 0888)

SymbolMeaning
AOutdoor Cable
PPaper Insulation
BHelical Galvanized Steel Tape
YPolyvinyl Chloride (PVC)

How to read a VDE telecom, signal and fibre cables (DIN VDE 0815, 0816, 0813, 0888) cable code

China (GB / JB/T / MT cable model codes)

SymbolMeaning
ATwin Cable
PCopper Screen As Braid
BPolypropylene (PP)
YPolyethylene (PE) Or Polyolefin

How to read a China (GB / JB/T / MT cable model codes) cable code

India (IS 1554 / IS 7098 cable code)

SymbolMeaning
AAluminium Conductor
PPaper Insulation
BBraiding, Compounding Or Varnishing
YPolyvinyl Chloride (PVC)

How to read a India (IS 1554 / IS 7098 cable code) cable code

How to read a VDE telecom, signal and fibre cables (DIN VDE 0815, 0816, 0813, 0888) cable code

A VDE telecom, signal and fibre cables (DIN VDE 0815, 0816, 0813, 0888) designation (Germany) is a row of letter groups, and each group stands for one part of the cable: conductor, insulation, screen, armour, sheath, or the standard it follows. The decoder knows 125 symbols for this system.

What does A mean in a VDE telecom, signal and fibre cables (DIN VDE 0815, 0816, 0813, 0888) cable code? A means Outdoor Cable.

What does P mean in a VDE telecom, signal and fibre cables (DIN VDE 0815, 0816, 0813, 0888) cable code? P means Paper Insulation; or Polymer Optical Fibre (Fibre Type).

What does B mean in a VDE telecom, signal and fibre cables (DIN VDE 0815, 0816, 0813, 0888) cable code? B means With Lightning Protection; or Bundled Cores, Unfilled; or Helical Galvanized Steel Tape; or Armoured.

What does Y mean in a VDE telecom, signal and fibre cables (DIN VDE 0815, 0816, 0813, 0888) cable code? Y means Polyvinyl Chloride (PVC).

Fire behaviour (EU CPR)

A CPR class is declared by the maker in its Declaration of Performance and printed on the sheath (EN 50575 cl 7). This decoder does not assign one. What the CPR classes mean →

Sources: EN 13501-6 draft and FprEN 50575:2014 final draft (drafts, not the published texts); IEC 60332-3-24:2000+A1:2008; EN 13501-3 draft A2.

Work with APBY

Who makes or stocks this cable?

Makers and stockists of this cable family appear here as sponsors for your region, each marked "Sponsored"; a listing never changes what this page says about the cable.

Related cables

More VDE telecom, signal and fibre cables (DIN VDE 0815, 0816, 0813, 0888) designations

APBY