AL/XLPE/CWS/LSZH

AL/XLPE/CWS/LSZH is a Layer-list designation (CU/XLPE/SWA/PVC style, IEC and BS practice) cable designation: AL = Aluminium Conductor; XLPE = Cross-Linked Polyethylene (XLPE); CWS = Copper Wire Screen (concentric copper wires); LSZH = Low Smoke Zero Halogen Compound.

1 coding system recognises this code

Layer-list designation (CU/XLPE/SWA/PVC style, IEC and BS practice)

SymbolMeaning
ALAluminium Conductor
XLPECross-Linked Polyethylene (XLPE)
CWSCopper Wire Screen (concentric copper wires)
LSZHLow Smoke Zero Halogen Compound

How to read a Layer-list designation (CU/XLPE/SWA/PVC style, IEC and BS practice) cable code

Fire behaviour (EU CPR)

A CPR class is declared by the maker in its Declaration of Performance and printed on the sheath (EN 50575 cl 7). This decoder does not assign one. What the CPR classes mean →

Sources: EN 13501-6 draft and FprEN 50575:2014 final draft (drafts, not the published texts); IEC 60332-3-24:2000+A1:2008; EN 13501-3 draft A2.

AL/XLPE/CWS/LSZH as the cable designer builds it, 3x95/25 12/20 kV

Overall diameter 63.3 mm, about 3,630 kg/km. Nominal values from the standard's tables for this size, computed, not a maker's data.

LayerMaterialThickness, mmOver the layer, mm
Conductor screen (semicon)Semiconducting0.6012.7
InsulationXLPE5.523.7
Insulation screen (semicon)Semiconducting0.8025.3
FillerSemiconducting54.5
Inner covering / beddingSemiconducting0.6055.7
Wire screenCopper65 × 0.7057.3
SheathHalogen-free (LSZH)3.063.3

AL/XLPE/CWS/LSZH on a drum

The smallest drum that passes every check, for 63.3 mm and about 3,630 kg/km as the cable designer builds it. Drums as their makers print them; lengths are estimates within a few per cent of the cable makers' own tables: whole layers, wound diameter 1.05 × OD, 66 mm freeboard under the flange rim.

LengthDrum size (its makers)LayersGross weight
500 mKTG 28 (2800 mm flange), wood KTG drums (Europe), Bayka, KTG5 of 62,990–3,055 kg
1,000 mNo single drum in KTG drums (Europe) takes it: the drum calculator splits it over several.

Barrel at least 20 × OD = 1,266 mm for a cable of this kind (Medium voltage, multi-core): KTG table, the cable's datasheet wins. A load rating is the drum maker's own.

Other lengths, drums and weights: the cable drum calculator

Load it on a truck: 1000 m on its drum in the loading planner

Laying, sizes and datasheet: AL/XLPE/CWS/LSZH

AL/XLPE/CWS/LSZH belongs to the family Medium voltage cables: the lowest laying temperature, bending radius, pulling, depth, drum handling and the test after laying, every rule with its sources. Laying and handling guide: Medium voltage cables