6PY is a JIS C 3410 shipboard cables cable designation: 6 = 6: six cores; P = P: EP rubber (EPR) insulation; Y = Y: PVC sheath; 6PY = 6PY: shipboard six-core power and lighting cable, 0.6/1 kV, EPR insulation, PVC sheath. 0.6/1 kV; conductor 90 C (TMC p.6, p.10, p.12). TMC catalogue name (TMC cites JIS C 3410(2010)); not a type of JIS C 3410:2010 Table 1.
1 coding system recognises this code
JIS C 3410 shipboard cables
| Symbol | Meaning |
|---|---|
6 | 6: six cores |
P | P: EP rubber (EPR) insulation |
Y | Y: PVC sheath |
6PY | 6PY: shipboard six-core power and lighting cable, 0.6/1 kV, EPR insulation, PVC sheath. 0.6/1 kV; conductor 90 C (TMC p.6, p.10, p.12). TMC catalogue name (TMC cites JIS C 3410(2010)); not a type of JIS C 3410:2010 Table 1 |
What is 6PY cable?
6PY: shipboard six-core power and lighting cable, 0.6/1 kV, EPR insulation, PVC sheath. Rating: 0.6/1 kV; conductor 90 C (TMC p.6, p.10, p.12). Standard: TMC catalogue name (TMC cites JIS C 3410(2010)); not a type of JIS C 3410:2010 Table 1.
Not in JIS C 3410:2010 Table 1 (pp. 2 to 8): TMC's own variant, so its values stay at seen level manufacturer. JIS Table 2 (p. 8) has F for four cores, but Table 1 lists no four or more core PY cable for power. Name printed in the TMC index p.4 ('(FA-) 6PY'). TMC 'Marine & Shipboard Cable, JIS C 3410(2010) / IEC 60092-350, 353, 354, 376' (manufacturer), p.4 'Code Designation': FA- flame retardant, FR- fire resistance, FR-FA-, S / D / T / F single to four cores for power and lighting, M multi core for control and signal, TT telephone and instrumentation; material letters, column alignment checked on a rendered image of p.4: insulation P EP rubber, Y PVC, C XLPE; sheath Y PVC; armouring C steel wire, CB copper alloy wire; protective covering Y PVC; others SLA common shield (AL/PS tape), -SLA individual shield (AL/PS tape), -S individual shield (copper braid), E earth wire, (C) cold type (not read here). Notes: telephone cables omit the insulation letter; CB for a copper alloy braid (0.6/1KV SPYCB, SPYCBY); E suffixed for an earth wire (0.6/1kV TPYE). Pp.6, 10, 12: stranded tinned annealed copper, EPR and PVC to JIS C 3410(2010), braid coverage min. 90 %, conductor 90 C, IEC 60332-1 (FA-: IEC 60332-3 Cat. A).
Documents and pages the readings were taken from
JIS C 3410 shipboard cables: how to read the cable type names
Fire behaviour (EU CPR)
PVC sheath (Y, 6PY).
Typically targeted, as declared by makers for this kind of construction in the examples this site checked (not the class of this cable):
EcaN1XV-R, Ahlsell (seller)Cca-s3,d1,a3FG16OR16, Nexans (La Triveneta Cavi)EcaU1000 R2V, Nexans (La Triveneta Cavi)EcaN2XSY, Waskönig+Walter (10 kV datasheet)
Listed as sources, alphabetically by maker. No maker pays to appear here.
A CPR class is declared by the maker in its Declaration of Performance and printed on the sheath (EN 50575 cl 7). This decoder does not assign one. What the CPR classes mean →
Sources: EN 13501-6 draft and FprEN 50575:2014 final draft (drafts, not the published texts); IEC 60332-3-24:2000+A1:2008; EN 13501-3 draft A2.
Work with 6PY
Who makes or stocks this cable?
Makers and stockists of this cable family appear here as sponsors for your region, each marked "Sponsored"; a listing never changes what this page says about the cable.