2XYRYFL
2XYRYFL is a DIN VDE 0271/0276 power cables (Germany) cable designation: 2X = Cross-Linked Polyethylene (XLPE); Y = Polyvinyl Chloride (PVC); R = Round Steel Wire; Y = Polyvinyl Chloride (PVC); FL = Longitudinal & Radial Water Resistant Tape.
2 coding systems recognise this code
Standard, worked reading and related types
Worked reading of 2XYRYFL:
2XYRYFL: 2X = Cross-Linked Polyethylene (XLPE); Y = Polyvinyl Chloride (PVC); R = Round Steel Wire; Y = Polyvinyl Chloride (PVC); FL = Longitudinal & Radial Water Resistant Tape
DIN VDE 0271/0276 power cables (Germany)
| Symbol | Meaning |
|---|---|
2X | Cross-Linked Polyethylene (XLPE) |
Y | Polyvinyl Chloride (PVC) |
R | Round Steel Wire |
Y | Polyvinyl Chloride (PVC) |
FL | Longitudinal & Radial Water Resistant Tape |
How to read a DIN VDE 0271/0276 power cables (Germany) cable code
India (IS 1554 / IS 7098 cable code)
| Symbol | Meaning |
|---|---|
2X | Cross-Linked Polyethylene (XLPE) |
Y | Polyvinyl Chloride (PVC) |
R | Elastomer (Rubber) Insulation Or Outer Sheath |
Y | Polyvinyl Chloride (PVC) |
F | Flat Galvanized Steel Wire (Strip) Armour |
L | Lead Sheath |
How to read a India (IS 1554 / IS 7098 cable code) cable code
How to read a DIN VDE 0271/0276 power cables (Germany) cable code
A DIN VDE 0271/0276 power cables (Germany) designation (Germany) is a row of letter groups, and each group stands for one part of the cable: conductor, insulation, screen, armour, sheath, or the standard it follows. The decoder knows 51 symbols for this system.
What does 2X mean in a DIN VDE 0271/0276 power cables (Germany) cable code? 2X means Cross-Linked Polyethylene (XLPE).
What does Y mean in a DIN VDE 0271/0276 power cables (Germany) cable code? Y means Polyvinyl Chloride (PVC).
What does R mean in a DIN VDE 0271/0276 power cables (Germany) cable code? R means Round Steel Wire.
What does FL mean in a DIN VDE 0271/0276 power cables (Germany) cable code? FL means Longitudinal & Radial Water Resistant Tape.
Fire behaviour (EU CPR)
PVC sheath (Y).
Typically targeted, as declared by makers for this kind of construction in the examples this site checked (not the class of this cable):
EcaN1XV-R, Ahlsell (seller)Cca-s3,d1,a3FG16OR16, Nexans (La Triveneta Cavi)EcaU1000 R2V, Nexans (La Triveneta Cavi)EcaN2XSY, Waskönig+Walter (10 kV datasheet)
Listed as sources, alphabetically by maker. No maker pays to appear here.
A CPR class is declared by the maker in its Declaration of Performance and printed on the sheath (EN 50575 cl 7). This decoder does not assign one. What the CPR classes mean →
Sources: EN 13501-6 draft and FprEN 50575:2014 final draft (drafts, not the published texts); IEC 60332-3-24:2000+A1:2008; EN 13501-3 draft A2.
Work with 2XYRYFL
Who makes or stocks this cable?
Makers and stockists of this cable family appear here as sponsors for your region, each marked "Sponsored"; a listing never changes what this page says about the cable.