2XCELYTG2Y
2XCELYTG2Y is a India (IS 1554 / IS 7098 cable code) cable designation: 2X = Cross-Linked Polyethylene (XLPE); CE = Individual Copper Wire Braid Or Concentric Copper Wire Screen; Ly = Alloyed Lead Sheath For General Use; Tg = Galvanised Double Steel Tape Armour; 2Y = Polyethylene Outer Sheath.
1 coding system recognises this code
Standard, worked reading and related types
Worked reading of 2XCELYTG2Y:
2XCELYTG2Y: 2X = Cross-Linked Polyethylene (XLPE); CE = Individual Copper Wire Braid Or Concentric Copper Wire Screen; Ly = Alloyed Lead Sheath For General Use; Tg = Galvanised Double Steel Tape Armour; 2Y = Polyethylene Outer Sheath
India (IS 1554 / IS 7098 cable code)
| Symbol | Meaning |
|---|---|
2X | Cross-Linked Polyethylene (XLPE) |
CE | Individual Copper Wire Braid Or Concentric Copper Wire Screen |
Ly | Alloyed Lead Sheath For General Use |
Tg | Galvanised Double Steel Tape Armour |
2Y | Polyethylene Outer Sheath |
How to read a India (IS 1554 / IS 7098 cable code) cable code
How to read a India (IS 1554 / IS 7098 cable code) cable code
A India (IS 1554 / IS 7098 cable code) designation (India) is a row of letter groups, and each group stands for one part of the cable: conductor, insulation, screen, armour, sheath, or the standard it follows. The decoder knows 43 symbols for this system.
What does 2X mean in a India (IS 1554 / IS 7098 cable code) cable code? 2X means Cross-Linked Polyethylene (XLPE).
What does CE mean in a India (IS 1554 / IS 7098 cable code) cable code? CE means Individual Copper Wire Braid Or Concentric Copper Wire Screen.
What does Ly mean in a India (IS 1554 / IS 7098 cable code) cable code? Ly means Alloyed Lead Sheath For General Use.
What does Tg mean in a India (IS 1554 / IS 7098 cable code) cable code? Tg means Galvanised Double Steel Tape Armour.
What does 2Y mean in a India (IS 1554 / IS 7098 cable code) cable code? 2Y means Polyethylene Outer Sheath.
Fire behaviour (EU CPR)
PE sheath (2Y).
Typically targeted, as declared by makers for this kind of construction in the examples this site checked (not the class of this cable):
FcaYMeKrvaslqwd, TKFFcaNA2XS(F)2Y, Waskönig+Walter
Listed as sources, alphabetically by maker. No maker pays to appear here.
A CPR class is declared by the maker in its Declaration of Performance and printed on the sheath (EN 50575 cl 7). This decoder does not assign one. What the CPR classes mean →
Sources: EN 13501-6 draft and FprEN 50575:2014 final draft (drafts, not the published texts); IEC 60332-3-24:2000+A1:2008; EN 13501-3 draft A2.
Laying, sizes and datasheet: 2XCELYTG2Y
Terms on this page: oversheath (outer sheath) · steel tape armour
Work with 2XCELYTG2Y
Who makes or stocks this cable?
Makers and stockists of this cable family appear here as sponsors for your region, each marked "Sponsored"; a listing never changes what this page says about the cable.