ZWaH

ZWaH är en kabelbeteckning enligt BIS-typbeteckningar (Indien): Z = XL-HFFR-isolering, tvärbunden, halogenfri, flamskyddad (IS 17505 (Part 1) cl. 6, 19.4); Z i IS 7098 (Part 1) och IS 17048 är termoplastisk; Wa = Armering av omagnetiska runda trådar för enledarkablar för växelström, metallen anges inte (IS 17505 (Part 1) cl. 15.2, 19.4); H = Halogenfri yttermantel HFS-TP 90 eller HFS-XL 90 (IS 17505 (Part 1) cl. 9, 19.4); ZWaH = ZWaH: fire survival cable (IS 17505 (Part 1)): copper conductors under glass mica tape, XL-HFFR (crosslinked halogen-free flame-retardant) insulation, extruded inner sheath, non-magnetic round wire armour, zero halogen (HFS) outer sheath. Up to and including 1100 V a.c. and 1500 V d.c.; 90 C normal, 250 C short circuit (cl. 1); fire survival category F3, F30, F60 or F120 (cl. 3.5, Annex E), printed as "FS Cable" with the category (cl. 19.2) and in the code (cl. 19.4). IS 17505 (Part 1):2021, cable code cl. 19.4.

1 beteckningssystem känner igen denna beteckning

Standard, exempel och relaterade typer

Exempel på läsning av ZWaH:

  • ZWaH: Z = XL-HFFR-isolering, tvärbunden, halogenfri, flamskyddad (IS 17505 (Part 1) cl. 6, 19.4); Z i IS 7098 (Part 1) och IS 17048 är termoplastisk; Wa = Armering av omagnetiska runda trådar för enledarkablar för växelström, metallen anges inte (IS 17505 (Part 1) cl. 15.2, 19.4); H = Halogenfri yttermantel HFS-TP 90 eller HFS-XL 90 (IS 17505 (Part 1) cl. 9, 19.4); ZWaH = ZWaH: fire survival cable (IS 17505 (Part 1)): copper conductors under glass mica tape, XL-HFFR (crosslinked halogen-free flame-retardant) insulation, extruded inner sheath, non-magnetic round wire armour, zero halogen (HFS) outer sheath. Up to and including 1100 V a.c. and 1500 V d.c.; 90 C normal, 250 C short circuit (cl. 1); fire survival category F3, F30, F60 or F120 (cl. 3.5, Annex E), printed as "FS Cable" with the category (cl. 19.2) and in the code (cl. 19.4). IS 17505 (Part 1):2021, cable code cl. 19.4

Relaterade kabeltyper: ZWH · ZWWH

BIS-typbeteckningar (Indien)

SymbolBetydelse
ZXL-HFFR-isolering, tvärbunden, halogenfri, flamskyddad (IS 17505 (Part 1) cl. 6, 19.4); Z i IS 7098 (Part 1) och IS 17048 är termoplastisk
WaArmering av omagnetiska runda trådar för enledarkablar för växelström, metallen anges inte (IS 17505 (Part 1) cl. 15.2, 19.4)
HHalogenfri yttermantel HFS-TP 90 eller HFS-XL 90 (IS 17505 (Part 1) cl. 9, 19.4)
ZWaHZWaH: fire survival cable (IS 17505 (Part 1)): copper conductors under glass mica tape, XL-HFFR (crosslinked halogen-free flame-retardant) insulation, extruded inner sheath, non-magnetic round wire armour, zero halogen (HFS) outer sheath. Up to and including 1100 V a.c. and 1500 V d.c.; 90 C normal, 250 C short circuit (cl. 1); fire survival category F3, F30, F60 or F120 (cl. 3.5, Annex E), printed as "FS Cable" with the category (cl. 19.2) and in the code (cl. 19.4). IS 17505 (Part 1):2021, cable code cl. 19.4

Vad är kabeln ZWaH?

ZWaH: fire survival cable (IS 17505 (Part 1)): copper conductors under glass mica tape, XL-HFFR (crosslinked halogen-free flame-retardant) insulation, extruded inner sheath, non-magnetic round wire armour, zero halogen (HFS) outer sheath. Märkdata: Up to and including 1100 V a.c. and 1500 V d.c.; 90 C normal, 250 C short circuit (cl. 1); fire survival category F3, F30, F60 or F120 (cl. 3.5, Annex E), printed as "FS Cable" with the category (cl. 19.2) and in the code (cl. 19.4). Standard: IS 17505 (Part 1):2021, cable code cl. 19.4.

Dokument och sidor som uppgifterna kommer från

  • IS 17505 (Part 1):2021, from https://www.standardsbis.in/: cl. 1 (p. 1), 3.5 (pp. 2 to 3), 4 to 9 (p. 3), 10 to 12 (pp. 3 to 4), 14, 15 (p. 4), 19.2, 19.4 (p. 6)

BIS-typbeteckningar (Indien): så läser du kabeltypnamnen

Brandegenskaper (EU:s byggproduktförordning, CPR)

  • Halogenfri kompound (Z, H, ZWaH). Under CPR syns detta i tilläggsklasserna: surhet a1 till a3 (EN 60754-2) och rök s1 till s3 (EN 50399; för s1a och s1b tillkommer 3 m-kubprovet EN 61034-2). Huvudklassen, Aca till Fca, beror på hela kabelns uppbyggnad.

    Typiskt eftersträvade klasser, så som tillverkare har deklarerat dem för den här typen av uppbyggnad i de exempel som den här webbplatsen har kontrollerat (inte klassen för den här kabeln):

    Upptagna som källor, i alfabetisk ordning efter tillverkare. Ingen tillverkare betalar för att synas här.

  • Flamskyddad (Z, ZWaH). Enkelkabelprovet bakom klass Eca är EN 60332-1-2 (lågan slocknar inom 425 mm). Buntade kablar provas enligt IEC 60332-3-24 kategori C (1,5 l/m, 20 min, förkolning högst 2,5 m); det är inget prov för en CPR-klass, CPR-stegprovet för B1ca till Dca är EN 50399.

En CPR-klass deklareras av tillverkaren i dess prestandadeklaration och trycks på manteln (EN 50575 avsnitt 7). Den här avkodaren tilldelar ingen klass. Vad CPR-klasserna betyder →

Källor: utkast till EN 13501-6 och slututkast FprEN 50575:2014 (utkast, inte de publicerade texterna); IEC 60332-3-24:2000+A1:2008; utkast till EN 13501-3 A2.

Förläggning, areor och datablad: ZWaH

Termer på den här sidan: yttermantel

Arbeta med ZWaH

Vem tillverkar eller lagerhåller denna kabel?

Tillverkare och lagerhållare av denna kabelfamilj visas här som sponsorer för din region, var och en märkt "Sponsrad"; en listning ändrar aldrig vad denna sida säger om kabeln.

Närliggande kablar

Fler BIS-typbeteckningar (Indien) beteckningar

ZWaH