XnRUHAKXS är en kabelbeteckning enligt PN (Polen): Xn = Xn: flamskyddad PE-mantel (HD 620 S3 10-R tabell 5); R = R: tvärvattentäthet (radiell), en metallfolie limmad mot PE-manteln (HD 620 S3 10-R tabell 5, nr 9); U = Längstätad: vattenblockerande band; H = H: radiellt fält (HD 620 S3 10-R tabell 5); A = Arbetsledare av aluminium; K = kabel: kraftkabelfamilj; XS = Isolering av tvärbunden polyeten (XLPE); 1 = Typ 1: normal isoleringstjocklek; XnRUHAKXS = XnRUHAKXS(1): XRUHAKXS with a flame retardant PE sheath: single-core medium-voltage cable, aluminium conductor, XLPE, copper screen, radially and longitudinally sealed, 6/10 to 18/30 kV. 6/10, 8,7/15, 12/20 and 18/30 kV; 90 C conductor, 250 C short circuit (5 s) (HD 620 S3 10-R 1). HD 620 S3:2023 section 10-R, Table 5 type designations (p. 10-R-26) and Table 6 (p. 10-R-27); XLPE DIX 8 (1, p. 10-R-3). seen: standard; PN-HD 620 S3:2023-04 (makers).

1 beteckningssystem känner igen denna beteckning

Standard, exempel och relaterade typer

Exempel på läsning av XnRUHAKXS:

  • XnRUHAKXS: Xn = Xn: flamskyddad PE-mantel (HD 620 S3 10-R tabell 5); R = R: tvärvattentäthet (radiell), en metallfolie limmad mot PE-manteln (HD 620 S3 10-R tabell 5, nr 9); U = Längstätad: vattenblockerande band; H = H: radiellt fält (HD 620 S3 10-R tabell 5); A = Arbetsledare av aluminium; K = kabel: kraftkabelfamilj; XS = Isolering av tvärbunden polyeten (XLPE); 1 = Typ 1: normal isoleringstjocklek; XnRUHAKXS = XnRUHAKXS(1): XRUHAKXS with a flame retardant PE sheath: single-core medium-voltage cable, aluminium conductor, XLPE, copper screen, radially and longitudinally sealed, 6/10 to 18/30 kV. 6/10, 8,7/15, 12/20 and 18/30 kV; 90 C conductor, 250 C short circuit (5 s) (HD 620 S3 10-R 1). HD 620 S3:2023 section 10-R, Table 5 type designations (p. 10-R-26) and Table 6 (p. 10-R-27); XLPE DIX 8 (1, p. 10-R-3). seen: standard; PN-HD 620 S3:2023-04 (makers)

Relaterade kabeltyper: XRUHAKXS · XnUHAKXS · XRUHKXS · XUHAKXS

PN (Polen)

SymbolBetydelse
XnXn: flamskyddad PE-mantel (HD 620 S3 10-R tabell 5)
RR: tvärvattentäthet (radiell), en metallfolie limmad mot PE-manteln (HD 620 S3 10-R tabell 5, nr 9)
ULängstätad: vattenblockerande band
HH: radiellt fält (HD 620 S3 10-R tabell 5)
AArbetsledare av aluminium
Kkabel: kraftkabelfamilj
XSIsolering av tvärbunden polyeten (XLPE)
1Typ 1: normal isoleringstjocklek
XnRUHAKXSXnRUHAKXS(1): XRUHAKXS with a flame retardant PE sheath: single-core medium-voltage cable, aluminium conductor, XLPE, copper screen, radially and longitudinally sealed, 6/10 to 18/30 kV. 6/10, 8,7/15, 12/20 and 18/30 kV; 90 C conductor, 250 C short circuit (5 s) (HD 620 S3 10-R 1). HD 620 S3:2023 section 10-R, Table 5 type designations (p. 10-R-26) and Table 6 (p. 10-R-27); XLPE DIX 8 (1, p. 10-R-3). seen: standard; PN-HD 620 S3:2023-04 (makers)

Vad är kabeln XnRUHAKXS?

XnRUHAKXS: XnRUHAKXS(1): XRUHAKXS with a flame retardant PE sheath: single-core medium-voltage cable, aluminium conductor, XLPE, copper screen, radially and longitudinally sealed, 6/10 to 18/30 kV. Märkdata: 6/10, 8,7/15, 12/20 and 18/30 kV; 90 C conductor, 250 C short circuit (5 s) (HD 620 S3 10-R 1). Standard: HD 620 S3:2023 section 10-R, Table 5 type designations (p. 10-R-26) and Table 6 (p. 10-R-27); XLPE DIX 8 (1, p. 10-R-3). seen: standard; PN-HD 620 S3:2023-04 (makers).

Dokument och sidor som uppgifterna kommer från

  • HD 620 S3:2023 10-R Table 5, p. 10-R-26; Tables 6 to 8, pp. 10-R-27 to 10-R-29; No. 7, 9, p. 10-R-7

PN (Polen): så läser du kabeltypnamnen

Brandegenskaper (EU:s byggproduktförordning, CPR)

  • Flamskyddad (Xn, XnRUHAKXS). Enkelkabelprovet bakom klass Eca är EN 60332-1-2 (lågan slocknar inom 425 mm). Buntade kablar provas enligt IEC 60332-3-24 kategori C (1,5 l/m, 20 min, förkolning högst 2,5 m); det är inget prov för en CPR-klass, CPR-stegprovet för B1ca till Dca är EN 50399.

  • PE-mantel (Xn).

    Typiskt eftersträvade klasser, så som tillverkare har deklarerat dem för den här typen av uppbyggnad i de exempel som den här webbplatsen har kontrollerat (inte klassen för den här kabeln):

    Upptagna som källor, i alfabetisk ordning efter tillverkare. Ingen tillverkare betalar för att synas här.

En CPR-klass deklareras av tillverkaren i dess prestandadeklaration och trycks på manteln (EN 50575 avsnitt 7). Den här avkodaren tilldelar ingen klass. Vad CPR-klasserna betyder →

Källor: utkast till EN 13501-6 och slututkast FprEN 50575:2014 (utkast, inte de publicerade texterna); IEC 60332-3-24:2000+A1:2008; utkast till EN 13501-3 A2.

Arbeta med XnRUHAKXS