How to read a cable code: guides per coding system · Thermocouple cables (IEC 60584-3) · International
Thermocouple cables (IEC 60584-3): how to read the cable type names
Each name in Thermocouple cables (IEC 60584-3) stands for a whole cable type: KX, for example, comes with its own construction, standard and rating. The decoder knows 12 types of this system. Below: how the names are built, every type with its rating, and the sources the table names.
How a name is built
The type table splits each name into parts and records what each part means. A few names taken apart:
KX
| K | Thermocouple type K: NiCr / NiSi (positive / negative leg) |
| X | X: thermo cable, conductors of the thermocouple alloy itself |
KX: thermocouple extension cable, conductors of the type K alloys, NiCr10 / NiSi3
KCA
| K | Compensating cable for type K thermocouples, variant A: iron / copper-nickel 22 (GB/T 4989-2013 Table 1) |
| CA | CA: compensating cable (C) with a substitute alloy, variant A |
KCA: compensating cable for a type K thermocouple, variant A, iron / copper-nickel 22, cable 0 to +150 C
KCB
| K | Compensating cable for type K thermocouples, variant B: copper / copper-nickel 40 (GB/T 4989-2013 Table 1) |
| CB | CB: compensating cable (C) with a substitute alloy, variant B |
KCB: compensating cable for a type K thermocouple, variant B, copper / copper-nickel 40, cable 0 to +100 C
NC
| N | Compensating cable for type N thermocouples: iron / copper-nickel 18 (GB/T 4989-2013 Table 1) |
| C | C: compensating cable, conductors of another composition than the thermocouple (type N has one variant, no A or B) |
NC: compensating cable for a type N thermocouple, iron / copper-nickel 18, cable 0 to +150 C
Every part used in the names
| Part | Meaning | Used in |
|---|---|---|
| X | X: thermo cable, conductors of the thermocouple alloy itself | KX JX TX EX NX |
| CA | CA: compensating cable (C) with a substitute alloy, variant A | KCA RCA SCA |
| CB | CB: compensating cable (C) with a substitute alloy, variant B | KCB RCB SCB |
| K | Thermocouple type K: NiCr / NiSi (positive / negative leg) | KX |
| J | Thermocouple type J: Fe / CuNi (positive / negative leg) | JX |
| T | Thermocouple type T: Cu / CuNi (positive / negative leg) | TX |
| E | Thermocouple type E: NiCr / CuNi (positive / negative leg) | EX |
| N | Thermocouple type N: NiCrSi / NiSi (positive / negative leg) | NX |
| K | Compensating cable for type K thermocouples, variant A: iron / copper-nickel 22 (GB/T 4989-2013 Table 1) | KCA |
| K | Compensating cable for type K thermocouples, variant B: copper / copper-nickel 40 (GB/T 4989-2013 Table 1) | KCB |
| R | Compensating cable for type R thermocouples: copper / copper-nickel 0.6 (GB/T 4989-2013 Table 1) | RCB |
| S | Compensating cable for type S thermocouples: copper / copper-nickel 0.6 (GB/T 4989-2013 Table 1) | SCB |
| N | Compensating cable for type N thermocouples: iron / copper-nickel 18 (GB/T 4989-2013 Table 1) | NC |
| C | C: compensating cable, conductors of another composition than the thermocouple (type N has one variant, no A or B) | NC |
| R | Thermocouple type R (PtRh13-Pt); IEC 60584-3 names no alloys for its compensating cable | RCA |
| S | Thermocouple type S (PtRh10-Pt); IEC 60584-3 names no alloys for its compensating cable | SCA |
What the type table says about the names
Quoted from the notes of the type table, with the types they belong to.
- The old DIN 43710 names L / U (LX, UX), withdrawn in 1994, come from maker catalogues (manufacturer). (KX, JX, TX, EX, NX, KCA +3)
Every type in Thermocouple cables (IEC 60584-3)
| Type | Description | Rating |
|---|---|---|
KX | KX: thermocouple extension cable, conductors of the type K alloys, NiCr10 / NiSi3 | IEC 60584-3:2007 Table 1: tolerance class 1 ±60 µV (±1.5 C), class 2 ±100 µV (±2.5 C) for a cable at -25 to +200 C and the measuring junction at 900 C;the insulation may narrow the cable range (Table 1 Note 1: see the material pair, e.g. PVC/PVC) |
JX | JX: thermocouple extension cable, conductors of the type J alloys, iron / CuNi45 | IEC 60584-3:2007 Table 1: tolerance class 1 ±85 µV (±1.5 C), class 2 ±140 µV (±2.5 C) for a cable at -25 to +200 C and the measuring junction at 500 C;the insulation may narrow the cable range (Table 1 Note 1: see the material pair, e.g. PVC/PVC) |
TX | TX: thermocouple extension cable, conductors of the type T alloys, copper / CuNi45 | IEC 60584-3:2007 Table 1: tolerance class 1 ±30 µV (±0.5 C), class 2 ±60 µV (±1.0 C) for a cable at -25 to +100 C and the measuring junction at 300 C;the insulation may narrow the cable range (Table 1 Note 1: see the material pair, e.g. PVC/PVC) |
EX | EX: thermocouple extension cable, conductors of the type E alloys, NiCr10 / CuNi45 | IEC 60584-3:2007 Table 1: tolerance class 1 ±120 µV (±1.5 C), class 2 ±200 µV (±2.5 C) for a cable at -25 to +200 C and the measuring junction at 500 C;the insulation may narrow the cable range (Table 1 Note 1: see the material pair, e.g. PVC/PVC) |
NX | NX: thermocouple extension cable, conductors of the type N alloys, NiCr14Si / NiSi4Mg | IEC 60584-3:2007 Table 1: tolerance class 1 ±60 µV (±1.5 C), class 2 ±100 µV (±2.5 C) for a cable at -25 to +200 C and the measuring junction at 900 C;the insulation may narrow the cable range (Table 1 Note 1: see the material pair, e.g. PVC/PVC) |
KCA | KCA: compensating cable for a type K thermocouple, variant A, iron / copper-nickel 22, cable 0 to +150 C | IEC 60584-3:2007 Table 1: tolerance class 2 ±100 µV (±2.5 C) (no class 1) for a cable at 0 to +150 C and the measuring junction at 900 C;the insulation may narrow the cable range (Table 1 Note 1: see the material pair, e.g. PVC/PVC) |
KCB | KCB: compensating cable for a type K thermocouple, variant B, copper / copper-nickel 40, cable 0 to +100 C | IEC 60584-3:2007 Table 1: tolerance class 2 ±100 µV (±2.5 C) (no class 1) for a cable at 0 to +100 C and the measuring junction at 900 C;the insulation may narrow the cable range (Table 1 Note 1: see the material pair, e.g. PVC/PVC) |
RCB | RCB: compensating cable for a type R thermocouple, variant B, copper / copper-nickel 0.6, cable 0 to +200 C | IEC 60584-3:2007 Table 1: tolerance class 2 ±60 µV (±5.0 C) (no class 1) for a cable at 0 to +200 C and the measuring junction at 1000 C;the insulation may narrow the cable range (Table 1 Note 1: see the material pair, e.g. PVC/PVC) |
SCB | SCB: compensating cable for a type S thermocouple, variant B, copper / copper-nickel 0.6, cable 0 to +200 C | IEC 60584-3:2007 Table 1: tolerance class 2 ±60 µV (±5.0 C) (no class 1) for a cable at 0 to +200 C and the measuring junction at 1000 C;the insulation may narrow the cable range (Table 1 Note 1: see the material pair, e.g. PVC/PVC) |
NC | NC: compensating cable for a type N thermocouple, iron / copper-nickel 18, cable 0 to +150 C | IEC 60584-3:2007 Table 1: tolerance class 2 ±100 µV (±2.5 C) (no class 1) for a cable at 0 to +150 C and the measuring junction at 900 C; the insulation may narrow the cable range (Table 1 Note 1) |
RCA | RCA: compensating cable for a type R thermocouple, variant A, cable 0 to +100 C | IEC 60584-3:2007 Table 1: tolerance class 2 ±30 µV (±2.5 C) (no class 1) for a cable at 0 to +100 C and the measuring junction at 1000 C; the insulation may narrow the cable range (Table 1 Note 1) |
SCA | SCA: compensating cable for a type S thermocouple, variant A, cable 0 to +100 C | IEC 60584-3:2007 Table 1: tolerance class 2 ±30 µV (±2.5 C) (no class 1) for a cable at 0 to +100 C and the measuring junction at 1000 C; the insulation may narrow the cable range (Table 1 Note 1) |
Marks written next to the name
Words and marks the decoder reads next to a type name of this system: each adds a property to whatever type it is written with.
| Mark | Meaning | Written as |
|---|---|---|
| PVC/PVC | Core insulation / sheath: PVC / PVC, -25 to +80 C (maker shorthand, Lapp T8) | PVC/PVC |
| FEP/FEP | Core insulation / sheath: FEP / FEP, -100 to +205 C (maker shorthand, Lapp T8) | FEP/FEP |
| SI/SI | Core insulation / sheath: silicone / silicone, -50 to +180 C (maker shorthand, Lapp T8) | SI/SI |
| GL/GL | Core insulation / sheath: glass silk / glass silk, -50 to +200 C (maker shorthand, Lapp T8) | GL/GL |
| -1 | Tolerance class 1, last field of the IEC marking (IEC-KX-1; IEC 60584-3:2007 cl. 6.1, Table 1); extension cables only | -1 |
| -2 | Tolerance class 2, last field of the IEC marking (IEC-KX-2; IEC 60584-3:2007 cl. 6.1, Table 1) | -2 |
Common questions
What is KX cable?
KX: thermocouple extension cable, conductors of the type K alloys, NiCr10 / NiSi3. Rating: IEC 60584-3:2007 Table 1: tolerance class 1 ±60 µV (±1.5 C), class 2 ±100 µV (±2.5 C) for a cable at -25 to +200 C and the measuring junction at 900 C;the insulation may narrow the cable range (Table 1 Note 1: see the material pair, e.g. PVC/PVC). Standard: IEC 60584-3:2007 (ed. 2.0), Tables 1 and 2; alloys GB/T 4989-2013 Table 1. The name reads: K (Thermocouple type K: NiCr / NiSi (positive / negative leg)) + X (X: thermo cable, conductors of the thermocouple alloy itself).
What is KCA cable?
KCA: compensating cable for a type K thermocouple, variant A, iron / copper-nickel 22, cable 0 to +150 C. Rating: IEC 60584-3:2007 Table 1: tolerance class 2 ±100 µV (±2.5 C) (no class 1) for a cable at 0 to +150 C and the measuring junction at 900 C;the insulation may narrow the cable range (Table 1 Note 1: see the material pair, e.g. PVC/PVC). Standard: IEC 60584-3:2007 (ed. 2.0), Tables 1 and 2; alloys GB/T 4989-2013 Table 1. The name reads: K (Compensating cable for type K thermocouples, variant A: iron / copper-nickel 22 (GB/T 4989-2013 Table 1)) + CA (CA: compensating cable (C) with a substitute alloy, variant A).
What is the difference between KX and NX?
KX: thermocouple extension cable, conductors of the type K alloys, NiCr10 / NiSi3, IEC 60584-3:2007 Table 1: tolerance class 1 ±60 µV (±1.5 C), class 2 ±100 µV (±2.5 C) for a cable at -25 to +200 C and the measuring junction at 900 C;the insulation may narrow the cable range (Table 1 Note 1: see the material pair, e.g. PVC/PVC). NX: thermocouple extension cable, conductors of the type N alloys, NiCr14Si / NiSi4Mg, IEC 60584-3:2007 Table 1: tolerance class 1 ±60 µV (±1.5 C), class 2 ±100 µV (±2.5 C) for a cable at -25 to +200 C and the measuring junction at 900 C;the insulation may narrow the cable range (Table 1 Note 1: see the material pair, e.g. PVC/PVC). The names differ in: KX: K (Thermocouple type K: NiCr / NiSi (positive / negative leg)); NX: N (Thermocouple type N: NiCrSi / NiSi (positive / negative leg)).
Thermocouple cables (IEC 60584-3): what does X mean in a cable name?
X means: X: thermo cable, conductors of the thermocouple alloy itself. Used in KX, JX, TX, EX, NX.
Thermocouple cables (IEC 60584-3): what does PVC/PVC mean next to a cable name?
PVC/PVC: Core insulation / sheath: PVC / PVC, -25 to +80 C (maker shorthand, Lapp T8). Written as PVC/PVC.
What is KCB cable?
KCB: compensating cable for a type K thermocouple, variant B, copper / copper-nickel 40, cable 0 to +100 C. Rating: IEC 60584-3:2007 Table 1: tolerance class 2 ±100 µV (±2.5 C) (no class 1) for a cable at 0 to +100 C and the measuring junction at 900 C;the insulation may narrow the cable range (Table 1 Note 1: see the material pair, e.g. PVC/PVC). Standard: IEC 60584-3:2007 (ed. 2.0), Tables 1 and 2; alloys GB/T 4989-2013 Table 1. The name reads: K (Compensating cable for type K thermocouples, variant B: copper / copper-nickel 40 (GB/T 4989-2013 Table 1)) + CB (CB: compensating cable (C) with a substitute alloy, variant B).
Sources the type table names
Standards named in the table
- IEC 60584-3:2007 (ed. 2.0), Tables 1 and 2
- alloys GB/T 4989-2013 Table 1
Documents and pages the readings were taken from
- IEC 60584-3:2007 (ed. 2.0): cl. 3.1.1, 3.1.2 (p. 4), Table 1 (p. 5), cl. 5.1 to 5.3 and Table 2 (pp. 5 to 6), cl. 6.1 (p. 6)
- ANSI MC96.1-1982 (Temperature Measurement Thermocouples, ISA): section 1, Tables 4 to 6, p. 11
- GB/T 4989-2013 Table 1, p. 2: the alloys (from the SAMR portal https://openstd.samr.gov.cn/, read 2026-10-29, seen: standard)
- contentmedia.lappcdn.com/e/lapp/b-R7-dDFpUXxCtpj4fXQZw~~
- assets-cdn.helukabel.com/suppliers/Helukabel/documents/db/HELUKABEL_M48…
- tcdirect.co.uk/product-2-520-3/PVC-Insulated-Twisted-Pair-Thermocouple-…
- blog.wika.com/us//files/2018/02/international-thermocouple-color-charts…
- tcdirect.co.uk/thermocouple-sensors/thermocouple-colour-codes.aspx
- GB/T 4989-2013 Table 1, p. 2 (from the SAMR portal https://openstd.samr.gov.cn/, seen: standard): one SC and one RC type, copper / copper-nickel 0.6, not split into A and B
- IEC 60584-3:2007 (ed. 2.0): Table 1 (p. 5), cl. 6.1 (p. 6)
Taken from the type table of this site, with the sources named above. Check the manufacturer's datasheet before you specify a cable.