YE3S(AL)E
YE3S(AL)E is a TS 621 / TSE (Turkey) cable designation: Y = Underground Heavy-Duty Cable For Fixed Installation (Y Cable Family, TS 212); E3 = Cross-Linked Polyethylene (XLPE); S = Metallic (Copper) Screen; (AL) = Aluminium (Laminated To Outer Jacket); E = Polyethylene (PE).
1 coding system recognises this code
Standard, worked reading and related types
Worked reading of YE3S(AL)E:
YE3S(AL)E: Y = Underground Heavy-Duty Cable For Fixed Installation (Y Cable Family, TS 212); E3 = Cross-Linked Polyethylene (XLPE); S = Metallic (Copper) Screen; (AL) = Aluminium (Laminated To Outer Jacket); E = Polyethylene (PE)
TS 621 / TSE (Turkey)
| Symbol | Meaning |
|---|---|
Y | Underground Heavy-Duty Cable For Fixed Installation (Y Cable Family, TS 212) |
E3 | Cross-Linked Polyethylene (XLPE) |
S | Metallic (Copper) Screen |
(AL) | Aluminium (Laminated To Outer Jacket) |
E | Polyethylene (PE) |
How to read a TS 621 / TSE (Turkey) cable code
A TS 621 / TSE (Turkey) designation (Turkey) is a row of letter groups, and each group stands for one part of the cable: conductor, insulation, screen, armour, sheath, or the standard it follows. The decoder knows 41 symbols for this system.
What does y mean in a TS 621 / TSE (Turkey) cable code? y means Flat Conductor; or Underground Heavy-Duty Cable For Fixed Installation (Y Cable Family, TS 212).
What does E3 mean in a TS 621 / TSE (Turkey) cable code? E3 means Cross-Linked Polyethylene (XLPE).
What does s mean in a TS 621 / TSE (Turkey) cable code? s means Sector Shaped Conductor; or Metallic (Copper) Screen.
What does (AL) mean in a TS 621 / TSE (Turkey) cable code? (AL) means Aluminium (Laminated To Outer Jacket).
What does E mean in a TS 621 / TSE (Turkey) cable code? E means Polyethylene (PE).
Fire behaviour (EU CPR)
PE sheath (E).
Typically targeted, as declared by makers for this kind of construction in the examples this site checked (not the class of this cable):
FcaYMeKrvaslqwd, TKFFcaNA2XS(F)2Y, Waskönig+Walter
Listed as sources, alphabetically by maker. No maker pays to appear here.
A CPR class is declared by the maker in its Declaration of Performance and printed on the sheath (EN 50575 cl 7). This decoder does not assign one. What the CPR classes mean →
Sources: EN 13501-6 draft and FprEN 50575:2014 final draft (drafts, not the published texts); IEC 60332-3-24:2000+A1:2008; EN 13501-3 draft A2.
Work with YE3S(AL)E
Who makes or stocks this cable?
Makers and stockists of this cable family appear here as sponsors for your region, each marked "Sponsored"; a listing never changes what this page says about the cable.