XP 45

XP 45 is a JUS / SRPS / HRN N.C0.006 type names (former Yugoslavia) cable designation: X = Cross-linked polyethylene (XLPE) insulation; P = PVC sheath; 45 = 45: armour of flat galvanised steel wires with a counter-helical steel tape; XP 45 = XP 45: XLPE-insulated, PVC-sheathed power cable, 0,6/1 kV (N2XFGY, NA2XFGY); aluminium conductors: XP 45-A. 0,6/1 kV, test voltage 3,5 kV (Novkabel). SRPS N.C5.230.

1 coding system recognises this code

JUS / SRPS / HRN N.C0.006 type names (former Yugoslavia)

SymbolMeaning
XCross-linked polyethylene (XLPE) insulation
PPVC sheath
4545: armour of flat galvanised steel wires with a counter-helical steel tape
XP 45XP 45: XLPE-insulated, PVC-sheathed power cable, 0,6/1 kV (N2XFGY, NA2XFGY); aluminium conductors: XP 45-A. 0,6/1 kV, test voltage 3,5 kV (Novkabel). SRPS N.C5.230

What is XP 45 cable?

XP 45: XLPE-insulated, PVC-sheathed power cable, 0,6/1 kV (N2XFGY, NA2XFGY); aluminium conductors: XP 45-A. Rating: 0,6/1 kV, test voltage 3,5 kV (Novkabel). Standard: SRPS N.C5.230.

Novkabel pdf p.23: 'XP 45, XP 45-A', N2XFGY, NA2XFGY; armour: 'wrapped zinc-plated flat steel wire with contra helical zinc-plated steel tape'. Letters per the Split university text, Tablica 1.3 'Nacin oznacavanja energetskih kabela' (HRN N.C0.006 against HD 603 S1 / HD 620 S1): P = PVC insulation or sheath (HD Y), X = XLPE (2X), Y = green-yellow protective conductor (HD J), H = semiconducting layers round the insulation, E = PE sheath (2Y), Eh = semiconducting PE sheath, 00 = no mechanical protection, 44 = round steel wire armour, 49 = watertight electrical protection (S(F)), 91 = outer protective covering, A = aluminium; OJ / OV / SJ / SV = round solid / round stranded / sector solid / sector stranded conductor (RE / RM / SE / SM). The other two-digit codes are read off the Novkabel catalogue, which prints each SRPS name beside its VDE / HD and GOST twin.

Documents and pages the readings were taken from

  • Novkabel AD, 'Cables and Wires' catalogue, pdf p.23

JUS / SRPS / HRN N.C0.006 type names (former Yugoslavia): how to read the cable type names

Fire behaviour (EU CPR)

A CPR class is declared by the maker in its Declaration of Performance and printed on the sheath (EN 50575 cl 7). This decoder does not assign one. What the CPR classes mean →

Sources: EN 13501-6 draft and FprEN 50575:2014 final draft (drafts, not the published texts); IEC 60332-3-24:2000+A1:2008; EN 13501-3 draft A2.

Work with XP 45

Who makes or stocks this cable?

Makers and stockists of this cable family appear here as sponsors for your region, each marked "Sponsored"; a listing never changes what this page says about the cable.

Related cables

More JUS / SRPS / HRN N.C0.006 type names (former Yugoslavia) designations

XP 45