NHX-90
NHX-90 is a NTP (Peru) cable designation: NHX = Thermoset halogen-free (X = cross-linked, UNVERIFIED); NHX-90 = NHX-90 (LSOHX-90): thermoset halogen-free wire, 90 C (X = cross-linked, UNVERIFIED). 450/750 V, 90 C (UNVERIFIED voltage for NHX). NTP 370.252; IEC 60754-2; IEC 60332-3 cat C.
1 coding system recognises this code
Standard, worked reading and related types
Worked reading of NHX-90:
NHX-90: NHX = Thermoset halogen-free (X = cross-linked, UNVERIFIED); NHX-90 = NHX-90 (LSOHX-90): thermoset halogen-free wire, 90 C (X = cross-linked, UNVERIFIED). 450/750 V, 90 C (UNVERIFIED voltage for NHX). NTP 370.252; IEC 60754-2; IEC 60332-3 cat C
Related cable types: NH-90
NTP (Peru)
| Symbol | Meaning |
|---|---|
NHX | Thermoset halogen-free (X = cross-linked, UNVERIFIED) |
NHX-90 | NHX-90 (LSOHX-90): thermoset halogen-free wire, 90 C (X = cross-linked, UNVERIFIED). 450/750 V, 90 C (UNVERIFIED voltage for NHX). NTP 370.252; IEC 60754-2; IEC 60332-3 cat C |
What is NHX-90 cable?
NHX-90: NHX-90 (LSOHX-90): thermoset halogen-free wire, 90 C (X = cross-linked, UNVERIFIED). Rating: 450/750 V, 90 C (UNVERIFIED voltage for NHX). Standard: NTP 370.252; IEC 60754-2; IEC 60332-3 cat C.
Documents and pages the readings were taken from
Fire behaviour (EU CPR)
Halogen-free compound (NHX, NHX-90). Under the CPR this shows in the additional classes: acidity a1 to a3 (EN 60754-2) and smoke s1 to s3 (EN 50399; s1a and s1b add the 3 m cube test EN 61034-2). The main class, Aca to Fca, depends on the whole construction.
Typically targeted, as declared by makers for this kind of construction in the examples this site checked (not the class of this cable):
B2ca-s1a,d0,a11-CXKH-R-J, Kablo VrchlabíCca-s1b,d1,a1FG16(O)M16, Nexans (La Triveneta Cavi)B2ca-s1a,d1,a1FG18(O)M16, Nexans (La Triveneta Cavi)DcaFXQJ, Nexans NorwayCca-s1b,d1,a1H07Z1-K, Nexans SpainB2ca-s1,d2,a1AXQJ-RMF, Prysmian Sweden (12/20 kV)B2ca-s1a,d1,a1RZ1-K (AS), Top CableCca-s1b,d1,a1RZ1FZ1-K (AS), Top Cable
Listed as sources, alphabetically by maker. No maker pays to appear here.
A CPR class is declared by the maker in its Declaration of Performance and printed on the sheath (EN 50575 cl 7). This decoder does not assign one. What the CPR classes mean →
Sources: EN 13501-6 draft and FprEN 50575:2014 final draft (drafts, not the published texts); IEC 60332-3-24:2000+A1:2008; EN 13501-3 draft A2.
Work with NHX-90
Who makes or stocks this cable?
Makers and stockists of this cable family appear here as sponsors for your region, each marked "Sponsored"; a listing never changes what this page says about the cable.