MGT-XLPE/OSCR/LSZH/SWA/PVC
MGT-XLPE/OSCR/LSZH/SWA/PVC is a Layer-list designation (CU/XLPE/SWA/PVC style, IEC and BS practice) cable designation: MGT = Mica Glass Tape (fire barrier); XLPE = Cross-Linked Polyethylene (XLPE); OSCR = Overall Screen; LSZH = Low Smoke Zero Halogen Compound; SWA = Steel Wire Armour (round galvanised steel wires); PVC = Polyvinyl Chloride (PVC).
1 coding system recognises this code
Layer-list designation (CU/XLPE/SWA/PVC style, IEC and BS practice)
| Symbol | Meaning |
|---|---|
MGT | Mica Glass Tape (fire barrier) |
XLPE | Cross-Linked Polyethylene (XLPE) |
OSCR | Overall Screen |
LSZH | Low Smoke Zero Halogen Compound |
SWA | Steel Wire Armour (round galvanised steel wires) |
PVC | Polyvinyl Chloride (PVC) |
How to read a Layer-list designation (CU/XLPE/SWA/PVC style, IEC and BS practice) cable code
How to read a Layer-list designation (CU/XLPE/SWA/PVC style, IEC and BS practice) cable code
A Layer-list designation (CU/XLPE/SWA/PVC style, IEC and BS practice) designation (UK / International) is a row of letter groups, and each group stands for one part of the cable: conductor, insulation, screen, armour, sheath, or the standard it follows. The decoder knows 117 symbols for this system.
What does MGT mean in a Layer-list designation (CU/XLPE/SWA/PVC style, IEC and BS practice) cable code? MGT means Mica Glass Tape (fire barrier).
What does XLPE mean in a Layer-list designation (CU/XLPE/SWA/PVC style, IEC and BS practice) cable code? XLPE means Cross-Linked Polyethylene (XLPE).
What does OSCR mean in a Layer-list designation (CU/XLPE/SWA/PVC style, IEC and BS practice) cable code? OSCR means Overall Screen.
What does LSZH mean in a Layer-list designation (CU/XLPE/SWA/PVC style, IEC and BS practice) cable code? LSZH means Low Smoke Zero Halogen Compound.
What does SWA mean in a Layer-list designation (CU/XLPE/SWA/PVC style, IEC and BS practice) cable code? SWA means Steel Wire Armour (round galvanised steel wires).
What does PVC mean in a Layer-list designation (CU/XLPE/SWA/PVC style, IEC and BS practice) cable code? PVC means Polyvinyl Chloride (PVC).
Fire behaviour (EU CPR)
Halogen-free compound (LSZH). Under the CPR this shows in the additional classes: acidity a1 to a3 (EN 60754-2) and smoke s1 to s3 (EN 50399; s1a and s1b add the 3 m cube test EN 61034-2). The main class, Aca to Fca, depends on the whole construction.
Typically targeted, as declared by makers for this kind of construction in the examples this site checked (not the class of this cable):
B2ca-s1,d0,a11-CXKH-R-J, Kablo VrchlabíCca-s1b,d1,a1FG16(O)M16, Nexans (La Triveneta Cavi)B2ca-s1a,d1,a1FG18(O)M16, Nexans (La Triveneta Cavi)DcaFXQJ, Nexans NorwayCca-s1,d1,a1H07Z1-K, Nexans SpainB2caAXQJ-RMF, Prysmian Sweden (12/20 kV)Cca-s1b,d1,a1RZ1FZ1-K (AS), Top CableCca-s1a,d1,a1RZ1-K (AS), Top Cable (B2ca-s1a,d1,a1 for some sizes)
Listed as sources, alphabetically by maker. No maker pays to appear here.
A CPR class is declared by the maker in its Declaration of Performance and printed on the sheath (EN 50575 cl 7). This decoder does not assign one. What the CPR classes mean →
Sources: EN 13501-6 draft and FprEN 50575:2014 final draft (drafts, not the published texts); IEC 60332-3-24:2000+A1:2008; EN 13501-3 draft A2.
Laying, sizes and datasheet: MGT-XLPE/OSCR/LSZH/SWA/PVC
Terms on this page: steel wire armour
Work with MGT-XLPE/OSCR/LSZH/SWA/PVC
Related cables
- CU/XLPE/DSTA
- CU/XLPE/SWA/PVC
- XLPE
- CU/XLPE/CBPT/PVC
- CAS
- CU/XLPE/SWB/PVC
- AL/XLPE/PVC
- CU/XLPE/DSTA/PVC
- CU/XLPE/DSTA/XLPE
- CU
- CU/XLPE/PA
- AL/XLPE/CWS/PE
More Layer-list designation (CU/XLPE/SWA/PVC style, IEC and BS practice) designations