FVMT
FVMT is a TS 621 / TSE (Turkey) cable designation: F = Cable Resistant To Light & Normal Mechanical Load For Moving Installation; V = Flame Retardant; M = Concentric Copper Conductor; T = Heat Resistant.
4 coding systems recognise this code
Standard, worked reading and related types
Worked reading of FVMT:
FVMT: F = Cable Resistant To Light & Normal Mechanical Load For Moving Installation; V = Flame Retardant; M = Concentric Copper Conductor; T = Heat Resistant
Related cable types: FVMA
TS 621 / TSE (Turkey)
| Symbol | Meaning |
|---|---|
F | Cable Resistant To Light & Normal Mechanical Load For Moving Installation |
V | Flame Retardant |
M | Concentric Copper Conductor |
T | Heat Resistant |
CEI-UNEL 35011 (Italy)
| Symbol | Meaning |
|---|---|
F | Fine-Wired In Flexible Cables-Class 5 |
V | Impregnated Glass Tape |
M | Mineral Insulation |
T | One Or More Mica Glass Tapes, Or A Closed Glass Braid |
Norwegian type designation (NEK 606 offshore and Norwegian land cables)
| Symbol | Meaning |
|---|---|
F | PE Or PP + Filling Compound |
V | Screen (Draka key: aluminium screen; Nexans key: screen, optionally with PVC) |
M | Polyester |
T | Cross-Linked Polyethylene (XLPE) |
How to read a Norwegian type designation (NEK 606 offshore and Norwegian land cables) cable code
SS 424 17 01 (Sweden)
| Symbol | Meaning |
|---|---|
F | Copper Conductor, Few-Stranded (Class 2) |
V | Rubber Without Outer Sheath (Older Cables: Natural Rubber) |
M | Copper Conductor, Few-Stranded |
T | Fluoroplastic |
How to read a TS 621 / TSE (Turkey) cable code
A TS 621 / TSE (Turkey) designation (Turkey) is a row of letter groups, and each group stands for one part of the cable: conductor, insulation, screen, armour, sheath, or the standard it follows. The decoder knows 41 symbols for this system.
What does F mean in a TS 621 / TSE (Turkey) cable code? F means Cable Resistant To Light & Normal Mechanical Load For Moving Installation.
What does v mean in a TS 621 / TSE (Turkey) cable code? v means Flame Retardant; or Polyvinyl Chloride (PVC).
What does M mean in a TS 621 / TSE (Turkey) cable code? M means Concentric Copper Conductor.
What does t mean in a TS 621 / TSE (Turkey) cable code? t means Heat Resistant.
Fire behaviour (EU CPR)
Flame retardant (V). The single-cable test behind class Eca is EN 60332-1-2 (the flame stops within 425 mm). Bunched cables are tested by IEC 60332-3-24 category C (1.5 l/m, 20 min, char at most 2.5 m), which is not a CPR class test; the CPR ladder test for B1ca to Dca is EN 50399.
A CPR class is declared by the maker in its Declaration of Performance and printed on the sheath (EN 50575 cl 7). This decoder does not assign one. What the CPR classes mean →
Sources: EN 13501-6 draft and FprEN 50575:2014 final draft (drafts, not the published texts); IEC 60332-3-24:2000+A1:2008; EN 13501-3 draft A2.
Work with FVMT
Who makes or stocks this cable?
Makers and stockists of this cable family appear here as sponsors for your region, each marked "Sponsored"; a listing never changes what this page says about the cable.