FLRY

FLRY is a Road vehicle wires (ISO 6722, LV 112, SAE J1128, JASO D611) cable designation: F = Vehicle (Fahrzeug): FL is the automotive low-voltage cable (Fahrzeugleitung); L = Cable (Leitung), the L of FL; R = Reduced insulation wall thickness (thin wall), hence a smaller outside diameter; Y = PVC insulation; FLRY = FLRY: thin-wall single core for road vehicles, PVC insulation over a flexible copper conductor, 60 V. 60 V (Coficab and TME sheets, seen through a search summary; Helukabel: operating voltage up to 24 V, test voltage 1 kV); -40 to +105 °C for 3000 h. ISO 6722-1 (PVC class T2, as Prysmian quotes it); LV 112-1; formerly DIN 72551-5 and -6.

1 coding system recognises this code

Standard, worked reading and related types

Worked reading of FLRY:

  • FLRY: F = Vehicle (Fahrzeug): FL is the automotive low-voltage cable (Fahrzeugleitung); L = Cable (Leitung), the L of FL; R = Reduced insulation wall thickness (thin wall), hence a smaller outside diameter; Y = PVC insulation; FLRY = FLRY: thin-wall single core for road vehicles, PVC insulation over a flexible copper conductor, 60 V. 60 V (Coficab and TME sheets, seen through a search summary; Helukabel: operating voltage up to 24 V, test voltage 1 kV); -40 to +105 °C for 3000 h. ISO 6722-1 (PVC class T2, as Prysmian quotes it); LV 112-1; formerly DIN 72551-5 and -6

Related cable types: FLRY-B · FLRYW

Road vehicle wires (ISO 6722, LV 112, SAE J1128, JASO D611)

SymbolMeaning
FVehicle (Fahrzeug): FL is the automotive low-voltage cable (Fahrzeugleitung)
LCable (Leitung), the L of FL
RReduced insulation wall thickness (thin wall), hence a smaller outside diameter
YPVC insulation
FLRYFLRY: thin-wall single core for road vehicles, PVC insulation over a flexible copper conductor, 60 V. 60 V (Coficab and TME sheets, seen through a search summary; Helukabel: operating voltage up to 24 V, test voltage 1 kV); -40 to +105 °C for 3000 h. ISO 6722-1 (PVC class T2, as Prysmian quotes it); LV 112-1; formerly DIN 72551-5 and -6

What is FLRY cable?

FLRY: thin-wall single core for road vehicles, PVC insulation over a flexible copper conductor, 60 V. Rating: 60 V (Coficab and TME sheets, seen through a search summary; Helukabel: operating voltage up to 24 V, test voltage 1 kV); -40 to +105 °C for 3000 h. Standard: ISO 6722-1 (PVC class T2, as Prysmian quotes it); LV 112-1; formerly DIN 72551-5 and -6.

Letters as a maker sheet spells them out (FLRYW sheet hosted by chipdip.ru, maker not named on it): "Automotive low voltage cable (FL) with reduced thickness of insulation (R), made of heat-resistant PVC (YW), with regularly stranded conductor (A)"; Prysmian calls the family "Fahrzeugleitungen mit reduziertem Außendurchmesser", Helukabel "reduzierte Isolierwanddicke". -A / -B after the name give the conductor (Helukabel: Typ A symmetric 1+6+12, an odd wire count with one wire in the centre; Typ B asymmetric); Sn after the size: tinned wires (Prysmian order example FLRY-B 0,5 Sn SWWS, the last letters the colour). Prysmian DF 049-2000 Index V (06.10.2020), FLRY-B: 0,35 mm² 12 x 0,21 mm, wall min 0,20 mm, outside 1,2 to 1,4 mm; 1 mm² 32 x 0,21, wall 0,24, 1,9 to 2,1 mm; 6 mm² 84 x 0,31, wall 0,32, 4,0 to 4,3 mm. ISO 6722-1 itself was not read: its classes are quoted from the makers.

Documents and pages the readings were taken from

Road vehicle wires (ISO 6722, LV 112, SAE J1128, JASO D611): how to read the cable type names

Fire behaviour (EU CPR)

A CPR class is declared by the maker in its Declaration of Performance and printed on the sheath (EN 50575 cl 7). This decoder does not assign one. What the CPR classes mean →

Sources: EN 13501-6 draft and FprEN 50575:2014 final draft (drafts, not the published texts); IEC 60332-3-24:2000+A1:2008; EN 13501-3 draft A2.

Work with FLRY

Who makes or stocks this cable?

Makers and stockists of this cable family appear here as sponsors for your region, each marked "Sponsored"; a listing never changes what this page says about the cable.

Related cables

More Road vehicle wires (ISO 6722, LV 112, SAE J1128, JASO D611) designations