EXZHELLENT

EXZHELLENT is a NTC / RETIE (Colombia) cable designation: EXZHELLENT = Halogen-free, flame-retardant, low smoke (HFFR-LS) Prysmian brand; the XHHW-2 version is zero halogen; EXZHELLENT = Exzhellent: Procables / Prysmian halogen-free, low smoke cable (Green = bio-based thermoplastic HFFR-LS). 600 V (XHHW-2 version 90 C wet or dry). NTC 6182 (halogen-free cable); RETIE; Res. 90795 of 2013 for crowded places.

2 coding systems recognise this code

Standard, worked reading and related types

Worked reading of EXZHELLENT:

  • EXZHELLENT: EXZHELLENT = Halogen-free, flame-retardant, low smoke (HFFR-LS) Prysmian brand; the XHHW-2 version is zero halogen; EXZHELLENT = Exzhellent: Procables / Prysmian halogen-free, low smoke cable (Green = bio-based thermoplastic HFFR-LS). 600 V (XHHW-2 version 90 C wet or dry). NTC 6182 (halogen-free cable); RETIE; Res. 90795 of 2013 for crowded places

Related cable types: EXZHELLENT XXI

NTC / RETIE (Colombia)

SymbolMeaning
EXZHELLENTHalogen-free, flame-retardant, low smoke (HFFR-LS) Prysmian brand; the XHHW-2 version is zero halogen
EXZHELLENTExzhellent: Procables / Prysmian halogen-free, low smoke cable (Green = bio-based thermoplastic HFFR-LS). 600 V (XHHW-2 version 90 C wet or dry). NTC 6182 (halogen-free cable); RETIE; Res. 90795 of 2013 for crowded places

China (GB / JB/T / MT cable model codes)

SymbolMeaning
ELow Smoke Zero Halogen Compound
XNatural Or Styrene-Butadiene Rubber
ZSmall Cross Sections
HRubber Sheath; Chlorosulphonated Polyethylene (CSM) Sheath In Marine Cables
ELow Smoke Zero Halogen Compound
LAluminium Conductor
LAluminium Conductor
ELow Smoke Zero Halogen Compound
NNylon Jacket
TCopper Conductor

How to read a China (GB / JB/T / MT cable model codes) cable code

What is EXZHELLENT cable?

EXZHELLENT: Exzhellent: Procables / Prysmian halogen-free, low smoke cable (Green = bio-based thermoplastic HFFR-LS). Rating: 600 V (XHHW-2 version 90 C wet or dry). Standard: NTC 6182 (halogen-free cable); RETIE; Res. 90795 of 2013 for crowded places.

Also sold in Chile with H07Z1-K (AS) and RZ1-K letters: the Chile table reads those lines.

Documents and pages the readings were taken from

NTC / RETIE (Colombia): how to read the cable type names

Fire behaviour (EU CPR)

  • Halogen-free compound (EXZHELLENT). Under the CPR this shows in the additional classes: acidity a1 to a3 (EN 60754-2) and smoke s1 to s3 (EN 50399; s1a and s1b add the 3 m cube test EN 61034-2). The main class, Aca to Fca, depends on the whole construction.

    Typically targeted, as declared by makers for this kind of construction in the examples this site checked (not the class of this cable):

    Listed as sources, alphabetically by maker. No maker pays to appear here.

  • Flame retardant (EXZHELLENT). The single-cable test behind class Eca is EN 60332-1-2 (the flame stops within 425 mm). Bunched cables are tested by IEC 60332-3-24 category C (1.5 l/m, 20 min, char at most 2.5 m), which is not a CPR class test; the CPR ladder test for B1ca to Dca is EN 50399.

A CPR class is declared by the maker in its Declaration of Performance and printed on the sheath (EN 50575 cl 7). This decoder does not assign one. What the CPR classes mean →

Sources: EN 13501-6 draft and FprEN 50575:2014 final draft (drafts, not the published texts); IEC 60332-3-24:2000+A1:2008; EN 13501-3 draft A2.

Work with EXZHELLENT

Who makes or stocks this cable?

Makers and stockists of this cable family appear here as sponsors for your region, each marked "Sponsored"; a listing never changes what this page says about the cable.

Related cables

More NTC / RETIE (Colombia) designations

EXZHELLENT